首页 | 本学科首页   官方微博 | 高级检索  
     检索      

基于长周期光纤光栅谐振光谱调制的氨氮降解监测研究
作者姓名:Liu HY  Liang DK  Zeng J  Cao ZB  Zeng JM
作者单位:1. 南京航空航天大学飞行器结构力学与控制教育部重点实验室,江苏,南京,210016
2. 南京航空航天大学材料科学与技术学院,江苏,南京,210016
3. 广西大学有色金属及材料加工新技术教育部重点实验室,广西,南宁,530004
基金项目:国家自然科学基金项目,江苏省自然科学基金项目,中国博士后科学基金项目,有色金属及材料加工新技术教育部重点实验室开放基金项目,南京航空航天大学研究生创新基地(实验室)开放基金项目 
摘    要:从长周期光纤光栅(LPFG)谐振透射光谱随外界环境折射率变化敏感特性的角度,详细研究了LPFG氨氮降解监测传感器的工作原理,分析了LPFG谐振峰波长与氨氮溶液浓度之间的对应关系.采用LPFG透射光谱检测技术,获得7种不同浓度氨氮溶液所对应的LPFG透射光谱曲线族,其谐振峰波长随溶液浓度的增大而逐渐向长波方向偏移,波长变化量从2.707 nm减至0.068 nm,且变化量与溶液浓度值呈良好的对应关系,其响应度为52.78 pm·mg-1·L.通过监测LPF-G光谱变化获取氨氮溶液的浓度,进而判断氨氮溶液的降解过程及程度.该方法对溶液直接进行监测,简单易行,测量及传导光路实现全光纤化,无需化学试剂标记,可实现对氨氮溶液降解过程的在线、精确及远距离遥测.

关 键 词:长周期光纤光栅(LPFG)  折射率  氨氮降解  光谱分析

Study on ammonia-N degradation monitoring by analyzing long-period fiber grating spectrum character
Liu HY,Liang DK,Zeng J,Cao ZB,Zeng JM.Study on ammonia-N degradation monitoring by analyzing long-period fiber grating spectrum character[J].Spectroscopy and Spectral Analysis,2010,30(9):2456-2459.
Authors:Liu Hong-yue  Liang Da-kai  Zeng Jie  Cao Zhi-bin  Zeng Jian-min
Institution:Ministry of Education Key Laboratory of Vehicle Structure and Control, Nanjing University of Aeronautics and Astronautics, Nanjing 210016, China. lhy320208@nuaa.edu.cn
Abstract:In the present paper, the principle of a long-period fiber grating (LPFG) ammonia-nitrogen degradation monitoring sensor was discussed in detail firstly based on a sensitive characteristic that the resonance spectrum of long-period fiber grating changes with refractive index in external environment. The relationship between the resonance peaking wavelength of long-period fiber grating and the concentration of ammonia-nitrogen solutions was also analyzed detailedly. Then, the long-period fiber grating spectrum measurement technology was selected to obtain long-period fiber grating spectrum curves corresponding to seven different kinds of concentration of ammonia-nitrogen solutions, and the resonance wavelengths increased with the increase in the concentration of ammonia-nitrogen solutions. The variations of the resonance wavelength decreased from 2.707 to 0.068 nm and had a relatively good corresponding relationship with the concentration values of ammonia-nitrogen solutions. The responsivity of this correlation is 52.78 pm x mg(-1) x L. The concentration of ammonia-nitrogen solutions was acquired exactly through the way of monitoring the changes of the spectrum attribute, at the same time, the process and the extent of ammonia-nitrogen wastewater degradation were estimated. This method, which can directly monitor the concentration of ammonia-nitrogen solutions, is simple and easy to operate. The measurement and transmission section of the system are completely composed of optical fiber, which can avoid the electronic interference. There is no necessary to use chemic reagent to sign the solutions, which are going to be degraded. In conclusion, the late-model long-period fiber grating ammonia-nitrogen degradation monitoring system could achieve a real time, rapid, accurate and long distance measurement.
Keywords:
本文献已被 万方数据 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号