首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Fluorimetric determination of aflatoxins by flow-injection analysis
Authors:Fernando Lazaro  M Dolores Luque de Castro and Miguel Valcarcel
Institution:(1) Department of Analytical Chemistry, Faculty of Sciences, University of Córdoba, Córdoba, Spain
Abstract:Summary A fast and inexpensive fluorimetric method for the determination of total aflatoxins (B1, B2, G1, and G2) in food of use in screening numerous samples suspectedly containing these substances is proposed. The sensitivity of the method (determination range between 0.5 and 200.0 ng ml–1) allows these analytes to be detected at concentrations well below legal limits; hence, separation-detection techniques such as HPLC need only be used with samples in which these compounds are found to occur. The method has been applied to maize, peanut and tapioca samples, obtaining average recoveries of 100.9 with deviations of ±5% with respect to 100% recovery.
Fluorometrische Bestimmung von Aflatoxinen durch Fließinjektionsanalyse
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号