首页 | 本学科首页   官方微博 | 高级检索  
     检索      


An interlaboratory comparison on whole water samples
Authors:Janine Richter  Saioa Elordui-Zapatarietxe  Håkan Emteborg  Ina Fettig  Julie Cabillic  Enrica Alasonati  Fanny Gantois  Claudia Swart  Taner Gokcen  Murat Tunc  Burcu Binici  Andres Rodriguez-Cea  Tea Zuliani  Adriana Gonzalez Gago  Daniel Pröfrock  Marjaana Nousiainen  George Sawal  Mirella Buzoianu  Rosemarie Philipp
Institution:1.BAM, Bundesanstalt für Materialforschung und –prüfung,Berlin,Germany;2.JRC-IRMM, Institute for Reference Materials and Measurements,Geel,Belgium;3.LNE, Laboratoire National de métrologie et d’essais,Paris,France;4.Physikalisch-Technische Bundesanstalt,Braunschweig,Germany;5.Chemistry Group Laboratory,Tubitak UME, National Metrology Institute,Gebze-Kocaeli,Turkey;6.Department of Physical and Analytical Chemistry, Faculty of Chemistry,University of Oviedo,Oviedo,Spain;7.Department of Environmental Sciences,Jozef Stefan Institute,Ljubljana,Slovenia;8.Helmholtz-Zentrum Geesthacht,Geesthacht,Germany;9.Finnish Environment Institute,Helsinki,Finland;10.Umweltbundesamt,Berlin,Germany;11.Biroul Roman de Metrologie Legala,Bucharest,Romania
Abstract:The European Water Framework Directive 2000/60/EC requires monitoring of organic priority pollutants in so-called whole water samples, i.e. in aqueous non-filtered samples that contain natural colloidal and suspended particulate matter. Colloids and suspended particles in the liquid phase constitute a challenge for sample homogeneity and stability. Within the joint research project ENV08 “Traceable measurements for monitoring critical pollutants under the European Water Framework Directive 2000/60/EC”, whole water test materials were developed by spiking defined amounts of aqueous slurries of ultra-finely milled contaminated soil or sediment and aqueous solutions of humic acid into a natural mineral water matrix. This paper presents the results of an European-wide interlaboratory comparison (ILC) using this type of test materials. Target analytes were tributyltin, polybrominated diphenyl ethers and polycyclic aromatic hydrocarbons in the ng/L concentration range. Results of the ILC indicate that the produced materials are sufficiently homogeneous and stable to serve as samples for, e.g. proficiency testing or method validation. To our knowledge, this is the first time that ready-to-use water materials with a defined amount of suspended particulate and colloidal matter have been applied as test samples in an interlaboratory exercise. These samples meet the requirements of the European Water Framework Directive. Previous proficiency testing schemes mainly employed filtered water samples fortified with a spike of the target analyte in a water-miscible organic solvent.
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号