Determination of pethidine in human plasma by LC–MS/MS |
| |
Authors: | Xianqin Wang Zheng Xiang Xiaojun Cai Haiya Wu Xuebao Wang Junwei Li Meiling Zhang |
| |
Affiliation: | 1. Analytical and Testing Center, Wenzhou Medical College, Wenzhou 325035, China;2. School of Pharmacy, Wenzhou Medical College, Wenzhou 325035, China;3. The Second Affiliated Hospital of Wenzhou Medical College, Wenzhou 325000, China |
| |
Abstract: | A sensitive and selective liquid chromatography–tandem mass spectrometry method for the determination of pethidine in human plasma was developed and validated over the concentration range of 4–2000 ng/mL. After addition of ketamine as internal standard, liquid–liquid extraction was used to produce a protein‐free extract. Chromatographic separation was achieved on a 100 × 2.1 mm, 5 µm particle, AllureTM PFP propyl column, with 45:40:15 (v/v/v) acetonitrile–methanol–water containing 0.2% formic acid as mobile phase. The MS data acquisition was accomplished by multiple reactions monitoring mode with positive electrospray ionization interface. The lower limit of quantification was 4 ng/mL; for inter‐day and intra‐day tests, the precision (RSD) for the entire validation was less than 7%, and the accuracy was within 95.9–106.5%. The method is sensitive and simple, and was successfully applied to analysis of samples of clinical intoxication. Copyright © 2010 John Wiley & Sons, Ltd. |
| |
Keywords: | pethidine LC– MS/MS human plasma |
|
|