首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Grid control over high currents in a cesium discharge with a cathode spot
Authors:V B Kaplan  A M Martsinovskii  I I Stolyarov
Abstract:We report on the results of investigation of a plasma switch with complete grid control in a discharge with a cathode spot on the liquid-metal cesium cathode without grid diaphragming. The retention of the working area of the grid relative to the anode area leads to an order-of-magnitude increase in the switching anode current (up to 20 A/cm2 over the anode area) and a substantial (up to 100 V and higher) increase in the switching voltages. The use of the cathode jet makes it possible to reduce the working pressures of cesium vapor (down to 10–3 Torr). We discuss the results of analysis of peculiarities of grid discharge quenching in such a switch, which make it possible to determine possible reasons for limitation of the working parameters of the switch and the ways of their further increase.
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏