Abstract: | A rapid, specific and sensitive liquid chromatography tandem mass spectrometry (LC–MS/MS) method was developed for the determination of penciclovir in human plasma. The method involved simple, one‐step SPE procedure coupled with a C18, 75 × 4.mm, 3µm column with a flow‐rate of 0.5 mL/min, and acyclovir was used as the internal standard. The Quattro Micro mass spectrometry was operated under the multiple reaction‐monitoring mode using the electrospray ionization technique. Using 250 µL plasma, the methods were validated over the concentration range 52.555–6626.181 ng/mL, with a lower limit of quantification of 52.55 ng/mL. The intra‐ and inter‐day precision and accuracy values were found to be within the assay variability limits as per the FDA guidelines. The developed assay method was applied to a clinical pharmacokinetic study in human volunteers. Copyright © 2010 John Wiley & Sons, Ltd. |
| |