首页 | 本学科首页   官方微博 | 高级检索  
     


Determination of the electron beam size at the Kurchatov synchrotron radiation source using an X-ray refractive lens
Authors:A. N. Artemiev  A. A. Snigirev  V. N. Korchuganov  A. G. Valentinov  V. V. Kvardakov  N. A. Artemiev  A. V. Zabelin  V. A. Rezvov  A. G. Maevskii  O. V. Naida  A. A. Dyatlov
Affiliation:(1) Russian Research Centre Kurchatov Institute, pl. Kurchatova 1, Moscow, 123182, Russia;(2) European Synchrotron Radiation Facility (ESRF), 6 rue Jules Horowitz, BP 220, 38043 Grenoble Cedex 9, France;(3) Laboratoire d’Optique Appliquee, ENSTA — Ecole Polytechnique, F-91761 Palaiseau Cedex, France
Abstract:
The electron beam size in the storage ring of the Kurchatov synchrotron radiation source at 2.5 GeV is determined using an x-ray two-dimensional parabolic refractive lens. The vertical size of the electron beam of the storage ring is found to be 270 μm, which exceeds the corresponding design value 140 μm (at a betatron coupling of 1%). The difference is explained by the imperfect geodetic arrangement of ring elements and the incomplete adjustment of the ring.
Keywords:
本文献已被 SpringerLink 等数据库收录!