首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Corrosion and biological behavior of nanostructured 316L stainless steel processed by severe plastic deformation
Authors:K Hajizadeh  H Maleki‐Ghaleh  A Arabi  Y Behnamian  E Aghaie  A Farrokhi  M G Hosseini  M H Fathi
Institution:1. Faculty of Materials Engineering, Sahand University of Technology, Tabriz, Iran;2. Department of Chemistry, Payame Noor University (PNU), Tehran, Iran;3. Department of Chemical and Materials Engineering, University of Alberta, Edmonton, Alberta, Canada;4. Electrochemistry Research Laboratory, Department of Physical Chemistry, Chemistry Faculty, University of Tabriz, Tabriz, Iran;5. Biomaterials Research Group, Department of Materials Engineering, Isfahan University of Technology, Isfahan, Iran
Abstract:Nanostructured metals have different mechanical, chemical, and physical behaviors in comparison with the microstructured ones. Numerous research studies demonstrated that the biological behavior of nanostructured metallic implants was improved significantly. Concerning the nanostructured metals, decreasing the corrosion rate and the releasing of hazardous ions from metallic implants, and thus increasing the biocompatibility of implants are due to improving the native oxide layer. In the present study, nanostructured 316L stainless steel (biomedical grade) was manufactured via equal channel angular pressing (ECAP) method. To do so, the 316L stainless steel (SS) was exposed to the ECAP operation for eight passes. The impact of the ECAP process on corrosion behavior of SS samples was evaluated through performing the electrochemical polarization corrosion tests in Ringer's solution. Scanning electron microscopy was employed to study the surface morphology of common SS and ECAPed SS sample after the electrochemical polarization tests. Moreover, the biological behavior of the samples was evaluated via cell culture using fibroblast cells. The corrosion test results revealed a substantial decrease of corrosion rate from 3.12 (coarse‐grained sample) to 0.42 μA cm?2 (for nanostructured). Furthermore, the cell proliferation in the interface of nanostructured sample and cell culture medium enhanced dramatically compared with the coarse‐grained one. The much better biological behavior of nanostructured SS sample in comparison with the coarse‐grained one is mostly due to the significant decrease of corrosion rate on the surface of SS samples, and the presence of much more chrome oxide on the surface of SS sample. Copyright © 2015 John Wiley & Sons, Ltd.
Keywords:stainless steel 316L  ECAP  nanostructured  corrosion  fibroblast cells
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号