首页 | 本学科首页   官方微博 | 高级检索  
     

HIRFL辐照终端照射野均匀度与离子通量的关系
引用本文:李强,颉红梅,李文建,党秉荣,马秋峰,卫增泉. HIRFL辐照终端照射野均匀度与离子通量的关系[J]. 原子核物理评论, 2003, 20(1): 48-51. DOI: 10.11804/NuclPhysRev.20.01.048
作者姓名:李强  颉红梅  李文建  党秉荣  马秋峰  卫增泉
作者单位:中国科学院近代物理研究所 甘肃兰州730000;
基金项目:国家自然科学基金资助项目(10205021),中国科学院西部之光课题(XB010612),教育部留学回国人员科研启动基金资助项目(JY020617)~~
摘    要:
采用固体核径迹探测器聚碳酸脂膜,测定了兰州重离子研究装置提供的55MeV/u40Ar和80MeV/u20Ne离子束经辐照终端束流均匀化扫描装置后照射野均匀度与离子通量之间的关系.结果表明:对于40Ar和20Ne离子束,离子通量小于1×106和2×107ions/cm2时,横向照射野均匀度缓Ne离子束照射慢增加;当离子通量分别介于1×106—1×107和2×107—1×108ions/cm2时,40Ar和20野均匀度逐渐增加;离子通量达到1×107和1×108ions/cm2时,40Ar和20Ne离子束照射野均匀度分别约为58%和61%.从而说明,辐照终端束流扫描装置对束流的均匀化程度目前并不能满足辐照生物效应、辐射育种和重离子治癌等研究工作的需要,须对其性能做进一步的提高. Using 55 MeV/u 40Ar and 80 MeV/u20Ne ion beams delivered by the Heavy Ion Research Facility at Lanzhou (HIRFL), the relationships between the irradiation homogeneities in irradiation fields generated by the beam scanning device located at the irradiation terminal of the HIRFL and ion fluence were measured respectively with 100 μm polycarbonate films by means of nuclear track detection. The results show that the homogeneity increases when the ion fluence are lower than ........

关 键 词:重离子束   照射野均匀度   离子通量   束流扫描装置
文章编号:1007-4627(2003)01-0048-04
收稿时间:1900-01-01
修稿时间:2002-09-20

Relationship between Homogeneity of Irradiation Field and Ion Fluence at Irradiation Terminal of HIRFL
LI Qiang,XIE Hong-mei,LI Wen-jian,DANG Bing-rong,MA Qiu-feng,WEI Zeng-quan. Relationship between Homogeneity of Irradiation Field and Ion Fluence at Irradiation Terminal of HIRFL[J]. Nuclear Physics Review, 2003, 20(1): 48-51. DOI: 10.11804/NuclPhysRev.20.01.048
Authors:LI Qiang  XIE Hong-mei  LI Wen-jian  DANG Bing-rong  MA Qiu-feng  WEI Zeng-quan
Affiliation:(Institute of Modern Physics; Chinese Academy of Sciences; Lanzhou 730000; China);
Abstract:
Using 55 MeV/u 40Ar and 80 MeV/u20Ne ion beams delivered by the Heavy Ion Research Facility at Lanzhou (HIRFL), the relationships between the irradiation homogeneities in irradiation fields generated by the beam scanning device located at the irradiation terminal of the HIRFL and ion fluence were measured respectively with 100 μm polycarbonate films by means of nuclear track detection. The results show that the homogeneity increases when the ion fluence are lower than ........
Keywords:heavy ion beam  homogeneity of irradiation field  ion fluence  beam scanning device
本文献已被 CNKI 万方数据 等数据库收录!
点击此处可从《原子核物理评论》浏览原始摘要信息
点击此处可从《原子核物理评论》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号