首页 | 本学科首页   官方微博 | 高级检索  
     


Development of a rapid and specific assay for detection of busulfan in human plasma by high-performance liquid chromatography/electrospray ionization tandem mass spectrometry
Authors:dos Reis Ederson Oliveira  Vianna-Jorge Rosane  Suarez-Kurtz Guilherme  Lima Edson Luiz da Silva  Azevedo Débora de Almeida
Affiliation:Departamento de Química Organica, Instituto de Química, Universidade Federal do Rio de Janeiro, Rio de Janeiro, RJ, Brazil.
Abstract:A sensitive and specific assay for detection of busulfan in human plasma was developed. The assay is based on rapid isolation of busulfan by liquid-liquid extraction with ethyl acetate, and detection by high-performance liquid chromatography with electrospray ionization and tandem mass spectrometry. 1,6-Bis(methanesulfonyloxy)hexane, a synthesized analogue of busulfan, was used as the internal standard (IS). The acquisition was performed in the multiple reaction monitoring mode; busulfan and the IS were detected with no interferences from plasma matrix. The method was linear over the range 5-2500 ng mL(-1), with r2 > 0.99 and a run time of only 3.5 min. The intra- and inter-assay precisions were in the ranges 2.1-11.9% and 3.2-10.1%, respectively, and the intra- and inter-assay accuracies were 92.2-107.6% and 94.7-104.1%, respectively. The absolute recoveries were 82.0% (20 ng mL(-1)), 90.6% (1000 ng mL(-1)) and 80.0% (2000 ng mL(-1)) for busulfan, and 89.1% for the IS (1000 ng mL(-1)). The limits of detection and quantification were 2 and 5 ng mL(-1), respectively. The validated method was successfully applied to analyze plasma samples obtained from six adults receiving doses of 1 mg kg(-1) in a conditioning regimen prior to bone marrow transplantation. A marked intra-patient variation in busulfan concentrations during the steady state was observed, which limits the application of pharmacokinetic modeling and suggests that continuous therapeutic monitoring is necessary for adequate individualized dosing. In this regard, the present assay brings important advantages relative to other methods described in the literature, i.e., it is highly specific and simple to perform, with a rapid chromatographic run time (3.5 min), and the whole procedure can be completed in 4-5 h, which would permit dose corrections after the third dose allowing earlier and better dosing adjustments towards the target level of busulfan.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号