排序方式: 共有8条查询结果,搜索用时 15 毫秒
1
1.
We study the influence of limited-view scanning on the depth imaging of photoacoustic tomography.The situation,in which absorbers are located at different depths with respect to the limited-view scanning trajectory,is called depth imaging and is investigated in this paper.The results show that limited-view scanning causes the reconstructed intensity of deep absorbers to be weaker than that of shallow ones and that deep absorbers will be invisible if the scanning range is too small.The concept of effective scanning angle is proposed to analyse that phenomenon.We find that an effective scanning angle can well predict the relationship between scanning angle and the intensity ratio of absorbers.In addition,limited-view scanning is employed to improve image quality. 相似文献
2.
光声成像结合了光学成像和声学成像的优点,是一种高分辨率,高对比度的无损伤医学成像技术.一种改进的同步迭代算法应用于光声图像重建.仿真和模拟结果表明,与传统的代数迭代算法相比,在90°,135°,180°的有限场光声成像中,此算法对测量误差的校正和迭代次数的收敛上具有较大的优势,图像重建的速度和成像质量都有了明显的提高.实验中,一种圆形扫描结构的光声成像装置,用于180°的有限场扫描,利用改进的同步迭代算法,重建出了高对比度和高分辨率(60μm)的鸡胚胎光声血管图像.实验证明,这种算法的应用,大幅度减少了数据采集时间,为光声成像技术运用于实时监测血流灌注和肿瘤光动力治疗的血管损伤效应提供了潜在的应用价值.
关键词:
光声成像
有限角度
代数迭代算法
光声血管成像 相似文献
3.
<正>With the development of the compressive sensing theory,the image reconstruction from the projections viewed in limited angles is one of the hot problems in the research of computed tomography technology.This paper develops an iterative algorithm for image reconstruction,which can fit most cases.This method gives an image reconstruction flow with the difference image vector,which is based on the concept that the difference image vector between the reconstructed and the reference image is sparse enough.Then the l_2-norm minimization method is used to reconstruct the difference vector to recover the image for flat subjects in limited angles.The algorithm has been tested with a thin planar phantom and a real object in limited-view projection data.Moreover,all the studies showed the satisfactory results in accuracy at a rather high reconstruction speed. 相似文献
4.
We study the influence of limited-view scanning on the depth imaging of photoacoustic tomography. The situation, in which absorbers are located at different depths with respect to the limited-view scanning trajectory, is called depth imaging and is investigated in this paper. The results show that limited-view scanning causes the reconstructed intensity of deep absorbers to be weaker than that of shallow ones and that deep absorbers will be invisible if the scanning range is too small. The concept of effective scanning angle is proposed to analyse that phenomenon. We find that an effective scanning angle can well predict the relationship between scanning angle and the intensity ratio of absorbers. In addition, limited-view scanning is employed to improve image quality. 相似文献
5.
In this paper, a limited-view optical tomography technique is presented, which contains an orthographic holography system,
an image processing system and the simultaneous algebraic reconstruction technique (SART). Using this technique, the temperature
field of a cross section in the flow of hot air from a nozzle is measured. The measured results are satisfactory.
The project supported by the National Natural Science Foundation and the State Science and Technology Commission of China 相似文献
6.
7.
Pulse decomposition-based analysis of PAT/TAT error caused by negative lobes in limited-view conditions 下载免费PDF全文
Pulse decomposition has been proven to be efficient to analyze complicated signals and it is introduced into the photo-acoustic and thermo-acoustic tomography to eliminate reconstruction distortions caused by negative lobes.During image reconstruction,negative lobes bring errors in the estimation of acoustic pulse amplitude,which is closely related to the distribution of absorption coefficient.The negative lobe error degrades imaging quality seriously in limited-view conditions because it cannot be offset so well as in full-view conditions.Therefore,a pulse decomposition formula is provided with detailed deduction to eliminate the negative lobe error and is incorporated into the popular delay-and-sum method for better reconstructing the image without additional complicated computation.Numerical experiments show that the pulse decomposition improves the image quality obviously in the limited-view conditions,such as separating adjacent absorbers,discovering a small absorber despite disturbance from a big absorber nearby,etc. 相似文献
8.
In this paper, we investigate the effects of the relative size and arrangement of a virtual transducer on the image quality in limited-view photoacoustic tomography. A virtual transducer refers to the acoustic scatterers used to reflect photoacoustic waves and improve the images reconstructed from incomplete PA signal. Size and spatial arrangement determine the performance of the virtual transducer. In this study, the scatterers utilized as virtual transducers are arranged in different manners, such as on a straight line or on an arc line. We find that virtual transducers with a big distributing angle can provide more significant image improvement than with a small distributing angle, which is similar to the true transducers. We also change the size of virtual transducer and study its influence on image quality. It is found that the bigger scatterers provide better images than the smaller ones. Especially, when the size of scatterers is reduced to the wavelength of photoacoustic wave, the image quality observably decreases, owing to the strong diffraction effect. Thus, it is suggested that the size of the acoustical scatterers should be much larger than the photoacoustic wavelength. The simulations are conducted, and the results could be helpful for the application and further study of virtual transducer theory in limited-view photoacoustic tomography. 相似文献
1