全文获取类型
收费全文 | 74篇 |
免费 | 2篇 |
国内免费 | 2篇 |
专业分类
化学 | 66篇 |
综合类 | 1篇 |
数学 | 8篇 |
物理学 | 3篇 |
出版年
2023年 | 1篇 |
2022年 | 3篇 |
2020年 | 5篇 |
2018年 | 2篇 |
2017年 | 2篇 |
2016年 | 1篇 |
2015年 | 2篇 |
2014年 | 1篇 |
2013年 | 3篇 |
2012年 | 1篇 |
2011年 | 6篇 |
2010年 | 1篇 |
2009年 | 2篇 |
2008年 | 4篇 |
2007年 | 7篇 |
2006年 | 2篇 |
2005年 | 1篇 |
2004年 | 7篇 |
2003年 | 3篇 |
2002年 | 4篇 |
2001年 | 2篇 |
2000年 | 1篇 |
1999年 | 2篇 |
1998年 | 1篇 |
1997年 | 1篇 |
1996年 | 1篇 |
1995年 | 1篇 |
1993年 | 1篇 |
1992年 | 1篇 |
1991年 | 3篇 |
1990年 | 1篇 |
1987年 | 1篇 |
1986年 | 1篇 |
1980年 | 1篇 |
1979年 | 1篇 |
1976年 | 1篇 |
排序方式: 共有78条查询结果,搜索用时 31 毫秒
1.
Pharmaceuticals require careful and precise determination of their impurities that might harm the user upon consumption. Although today, the most common technique for impurities identification is liquid chromatography‐mass spectrometry (LC‐MS/MS), it has several downsides due to the nature of the ionization method. Also, the analyses in many cases are targeted thus despite being present, some of the compounds will not be revealed. In this paper, we propose and show a new method for untargeted analysis and identification of impurities in active pharmaceutical ingredients (APIs). The instrument used for these analyses is a novel electron ionization (EI) LC‐MS with supersonic molecular beams (SMB). The EI‐LC‐MS‐SMB was implemented for analyses of several drug samples spiked with an impurity. The instrument provides EI mass spectra with enhanced molecular ions, named Cold EI, which increases the identification probabilities when the compound is identified with the aid of an EI library like National Institute of Standards and Technology (NIST). We analyzed ibuprofen and its impurities, and both the API and the expected impurity were identified with names and structures by the NIST library. Moreover, other unexpected impurities were found and identified proving the ability of the EI‐LC‐MS‐SMB system for truly untargeted analysis. The results show a broad dynamic range of four orders of magnitude at the same run with a signal‐to‐noise ratio of over 10 000 for the API and almost uniform response. 相似文献
2.
Alexander B. Fialkov Elias Ikonen Tiina Laaksonen Aviv Amirav 《Journal of mass spectrometry : JMS》2020,55(9)
A new type of photoionization ion source was developed for the ionization of cold molecules in supersonic molecular beams (named Cold PI). The system was based on a GC–MS with supersonic molecular beams and its fly‐through EI of cold molecules ion source (Cold EI) plus quadrupole mass analyzer. A continuously operated deuterium VUV photoionization lamp was added and placed above and between the supersonic nozzle and skimmer whereas the Cold EI ion source served only as a portion of the ion transfer ion optics. The supersonic nozzle and skimmer were voltage biased and the VUV light crossed the supersonic expansion about 10 mm from the nozzle. We obtained over three orders of magnitude enhancement in the relative abundance of the molecular ion of squalane in Cold PI versus in photoionization of this compound as a thermal compound. Accordingly, we also proved that standard photoionization is not as soft ionization method as previously perceived for large compounds. We found that Cold PI is as soft as and possibly softer than field ionization; thus, it could be the softest known ionization method. The ionization yield was about 200–300 times weaker than with Cold EI yet our limit of detection was about 200 femtogram in SIM mode for cholesterol and pyrene which is reasonable. Practically, all hydrocarbons gave only molecular ions with rather uniform response whereas alcohols gave some molecular ions plus major fragment ions particularly with a loss of water (similarly to field ionization). We tested Cold PI in the GC–MS analysis of diesel fuels and analyzed the time averaged data for group type information. We also found that we can analyze the diesel fuels by fast under 20‐s flow injection analysis in which the generated averaged mass spectrum of molecular ions only could serve for the characterization of fuels. 相似文献
3.
Jyoti Kannoujia Pavan Kumar Bangalore Srinivas Kantevari Prabhakar Sripadi 《Journal of mass spectrometry : JMS》2020,55(10)
The HPLC‐DAD and GC/MS methods were successfully used for the identification and characterization of the impurities in an agrochemical insecticide, bifenthrin technical. Three impurities ranging from 0.175%–0.541% were detected by the HPLC‐DAD method. The LC/MS technique with ESI or APCI source failed to detect the impurities detected by HPLC‐DAD, due to lack of ionization in ESI or APCI. The three impurities were enriched by prep‐HPLC, and then their structures were elucidated based on the GC/EIMS and CIMS data. The EI mass spectra of bifenthrin and its impurities displayed molecular ion and provided structure indicative fragment ions; the CIMS data further confirmed their molecular weight. The identity of the impurity 1 was further confirmed by the synthesis of the authentic sample followed by NMR and GC/MS data. 相似文献
4.
Characterization of N‐methylated amino acids by GC‐MS after ethyl chloroformate derivatization 下载免费PDF全文
B. Sudarshana Reddy V. Naresh Chary P. Pavankumar S. Prabhakar 《Journal of mass spectrometry : JMS》2016,51(8):638-650
Methylation is an essential metabolic process in the biological systems, and it is significant for several biological reactions in living organisms. Methylated compounds are known to be involved in most of the bodily functions, and some of them serve as biomarkers. Theoretically, all α‐amino acids can be methylated, and it is possible to encounter them in most animal/plant samples. But the analytical data, especially the mass spectral data, are available only for a few of the methylated amino acids. Thus, it is essential to generate mass spectral data and to develop mass spectrometry methods for the identification of all possible methylated amino acids for future metabolomic studies. In this study, all N‐methyl and N,N‐dimethyl amino acids were synthesized by the methylation of α‐amino acids and characterized by a GC‐MS method. The methylated amino acids were derivatized with ethyl chloroformate and analyzed by GC‐MS under EI and methane/CI conditions. The EI mass spectra of ethyl chloroformate derivatives of N‐methyl ( 1–18 ) and N,N‐dimethyl amino acids ( 19–35 ) showed abundant [M‐COOC2H5]+ ions. The fragment ions due to loss of C2H4, CO2, (CO2 + C2H4) from [M‐COOC2H5]+ were of structure indicative for 1–18 . The EI spectra of 19–35 showed less number of fragment ions when compared with those of 1–18 . The side chain group (R) caused specific fragment ions characteristic to its structure. The methane/CI spectra of the studied compounds showed [M + H]+ ions to substantiate their molecular weights. The detected EI fragment ions were characteristic of the structure that made easy identification of the studied compounds, including isomeric/isobaric compounds. Fragmentation patterns of the studied compounds ( 1–35 ) were confirmed by high‐resolution mass spectra data and further substantiated by the data obtained from 13C2‐labeled glycines and N‐ethoxycarbonyl methoxy esters. The method was applied to human plasma samples for the identification of amino acids and methylated amino acids. Copyright © 2016 John Wiley & Sons, Ltd. 相似文献
5.
Electron ionization (EI) mass spectra of 46 compounds from several different compound classes were measured. Their molecular ion abundances were compared as obtained with 70‐eV EI, with low eV EI (such as 14 eV), and with EI mass spectra of vibrationally cold molecules in supersonic molecular beams (Cold EI). We further compared these mass spectra in their National Institute of Standards and Technology (NIST) library identification probabilities. We found that
- Low eV EI is not a soft ionization method, and it has little or no influence on the molecular ion relative abundances for large molecules and those with weak or no molecular ions.
- Low eV EI for compounds with abundant or dominant molecular ions in their 70 eV mass spectra results in the reduction of low mass fragment ions abundances thereby reducing their NIST library identification probabilities thus rarely justifies its use in real‐world applications.
- Cold EI significantly enhances the relative abundance of the molecular ions particularly for large compounds; yet, it retains the low mass fragment ions; hence, Cold EI mass spectra can be effectively identified by the NIST library.
- Different standard EI ion sources provide different 70 eV EI mass spectra. Among the Agilent technologies ion sources, the “Extractor” exhibits relatively abundant molecular ions compared with the “Inert” ion source, while the “High efficiency source” (HES) provides mass spectra with depleted molecular ions compared with the “Inert” ion source or NIST library mass spectra.
6.
In recent years, increasing attention has been paid to “soft” photoionization (PI), which will potentially become a standard, universal ionization method. Tunable synchrotron vacuum ultraviolet (SVUV) light, a quasi-continuous light with good energy resolution and high photon flux, has proved an ideal source for “soft” PI in various research fields (e.g., combustion chemistry and molecular imaging).This review focuses on combinations of SVUV light with commonly used techniques (e.g., molecular-beam sampling, laser desorption, ion desorption, and thermal vaporization). These couplings have successful applications in flame chemistry, organic analysis, chemical imaging and aerosol mass spectrometry. 相似文献
7.
The mass spectra of a series of N‐aryl α,β‐unsaturated γ‐lactams were studied. Besides the molecular ion, the three characteristic fragments such as [M+‐29], [M+‐55], and [M+‐82] were commonly found in a series of N‐Aryl α,β‐unsaturated γ‐lactams in EI/MS. Further more the mechanism for the interpretation of these fragments is also de scribed. 相似文献
8.
A class of delayed oscillators of El Ni?o-southern oscillation (ENSO) models is considered. Using the delayed theory, the perturbed theory and other methods, the asymptotic expansions of the solutions for ENSO models are obtained and the asymptotic behaviour of solution of corresponding problem is studied. 相似文献
9.
A class of nonlinear coupled system for El Nino-Southern Oscillation(ENSO) model is considered.Using the asymptotic theory and method of variational iteration,the asymptotic expansion of the solution for ENSO models is obtained. 相似文献
10.
In-beam and matrix-isolation techniques have been used in the mass spectral studies of several categories of biologically significant compounds. These include amino acids, quaternary ammonium salts, vitamins and nucleosides. Molecular ions and/or (M+H)+ions are obtained, together with useful fragmentations, all of which are valuable in structural elucidations. Spectra obtained by this version of the in-beam technique are similar but not identical with those obtained by field desorption and secondary ion mass spectrometry. Ammonium and sodium chlorides, ammonium sulfate, p-toluenesulfonic and hydrochloric acids can all be used as a room temperature matrix. The detection limits for vitamin E and 2′-deoxyguanosine have been determined as 1 ngand 5 μg, respectively. 相似文献