1.
This review outlines automated methodologies developed for measuring arsenic in environmental samples. We report the state of the art of the most significant methods exploiting multicommutation flow techniques coupled to hydride generation-atomic fluorescence determination. We review analytical methods used and present a comparative evaluation of them. We also discuss the on-line pre-concentration procedure as being of particular interest in the development of fully automated methods.  相似文献   
2.
The process of ultrasound-assisted emulsification-microextraction (USAEME) was successfully applied for the first time for the extraction and pre-concentration of trace cadmium from water samples, followed by flame atomic absorption spectrometry (FAAS). In the proposed approach, sodium diethyldithiocarbamate trihydrate solution (NaDDTC·3H2O) was used as a chelating agent and carbon tetrachloride was selected as extraction solvent. Some effective parameters on the microextraction and the complex formation were selected and optimized. These parameters included extraction solvent type as well as extraction volume, time, temperature, and pH, the amount of the chelating agent, and salt effect. Under optimum conditions, an enrichment factor of 95 was obtained from only 5.0 mL of water sample. The calibration graph was linear in the range of 10-600 μg L−1 with a detection limit of 0.91 μg L−1. The relative standard deviation (R.S.D) for ten replicate measurements of 50 and 500 μg L−1 of cadmium were 2.56 and 1.62%. This proposed method was successfully applied in the analysis of four real environmental water samples and good spiked recoveries over the range of 96.5-101.7% were obtained.  相似文献   
3.
Chelating resins based on biopolymers, specifically cellulose, offers a green analytical method for determination of metal ions at trace levels present in various samples. It offers a fast, accurate and simple method for separation and pre-concentration of metal ions at low concentrations, prior to their determination by instrumental method. Cellulose based chelating resin (CELL-GLY) has been synthesised by immobilising glycine on it. CELL-GLY was used for the determination of trace amounts of Cu2+ and Ni2+ from aqueous solutions before their determination by FAAS. The preparation of CELL-GLY involves simple steps, based on natural and easily available biopolymer cellulose, which makes its use as chelating resin is a green method. The Cu2+ and Ni2+ can be quantitatively recovered from the CELL-GLY in the pH range 4.8–6.9 and 6.9-7.8 respectively with a recovery of more than 95% for each of these metal ions. Recovery of these metal ions using CELL-GLY was quantitative up to 35 °C. The detection limits for copper and nickel by FAAS were 1.20 ppb and 1.40 ppb, respectively. The method was successfully employed for the determination of trace amounts of Cu2+ and Ni2+ in various samples.  相似文献   
4.
The purpose of this study was to modify an automatic pre-concentration system to avoid water contamination and to apply this technique to ethane analysis in breath. The ion trap detector was very useful in monitoring the whole analytical procedure.  相似文献   
5.
我们设计并制作了集成有支持液膜萃取-反萃取试样预处理的毛细管电泳(SLMEBE-CCE)微流控芯片. 分别以荧光素钠和丁基罗丹明B作为模型待测物和共存物, 在该芯片上进行了在线试样预处理与毛细管电泳联用的初步实验.  相似文献   
6.
在化学战剂的诸种检测方法中, 质量型微传感器以其响应快速、使用简便等优点成为一种理想的检测手段. 但是这种传感器的使用往往受到检出限的限制, 对于低浓度的毒剂不能及时报警. 预富集技术的运用可以提高微传感器的检测限. 本文研制了一种预富集装置并对其进行了初步测试. 芥子气通过此预富集装置之后在QCM(石英晶体微天平)传感器上的检出限可以达到0.1 mg/m3.  相似文献   
7.
Poly(p-chloromethylstyrene-ethyleneglycoldimethacrylate) polymeric microbeads, poly(p-CMS-EGDMA), were synthesized and 1,5,9,13-tetrathiacyclohexadecane-3,11-diol (S4HD) was attached chemically onto the polymeric microbeads. Characterization of all microbeads was done by Fourier transform-infrared spectrometry (FT-IR) and elemental analyzer. The amount of attached 1,5,9,13-tetrathiacyclohexadecane-3,11-diol to the polymer was found to be 2.23 mmol g−1 polymers. The ligand attached microbeads, poly(p-CMS-EGDMA-S4HD), were used to examine the adsorption capacity of Pb(II), Cd(II), Hg(II) and Cr(II) ions for recovery, pre-concentration and the matrix elimination by changing the pH and the initial metal ion concentrations and also adsorption kinetics of the studied metal ions was determined. Pre-concentration factors for the studied toxic metal ions were found to be more than 500-fold and recovery was between 92 and 106%. In the drinking, lake, tap and sea-water samples from water lands, ultra-trace toxic metal ion concentrations were determined easily by using ligand modified microbeads after pre-concentration because of the high pre-concentration factor and easily matrix elimination using ligand modified microbeads. Reference sea-water material was used for the validation of the method and it was found that recovery, pre-concentration and the matrix elimination were performed perfectly. For the desorption of the toxic metal ions, 3 M HCl containing 0.8 M thiourea was used and desorption ratio was obtained more than 96%.  相似文献   
8.
Sahin F  Volkan M  Howard AG  Ataman OY 《Talanta》2003,60(5):1003-1009
Silica gel modified with 3-mercaptopropyl-trimethoxysilane was used for the selective separation and pre-concentration of selenite (Se(IV)) from aqueous solutions containing Se(IV) and selenate (Se(VI)). Over a wide range of acidity, from 2 mol l−1 HCl to pH 9.00, Se(IV) was taken up by the mercaptopropyl-silica with nearly 100% efficiency; Se(VI) however was unretained. Se(IV) content was determined by hydride generation atomic absorption spectrometry (HGAAS), following batch release of the selenium from the pre-concentration medium by acidic periodate. The overall pre-concentration efficiency, including both take-up and elution, in the range of 89-106%. The method was applied to spiked seawater samples containing as low as 800 ng l−1 Se in selenite form. This solid-phase extraction system offers several major advantages over conventional solvent extraction procedures. It firstly exhibits high selectivity for Se(IV) over Se(VI). Using the solid-phase media, pre-concentration of Se(IV) in dilute water samples can be carried out in the field, stabilizing the selenite-selenium in a convenient form for transport and storage. In addition, selenium stored on silica is derived solely from Se(IV) overcoming problems of selenium redox speciation changes and loss during storage.  相似文献   
9.
The present paper proposes a pre-concentration procedure for determination of lead and iron in several samples by flame atomic absorption spectrometry. In it, lead(II) and iron(III) ions are coprecipitated using the violuric acid-copper(II) system as collector. Afterwards, the precipitate is dissolved with 1 M HNO3 solution and the metal ions are determined. The optimization step was performed using factorial design involving the variables: pH, violuric acid mass (VA) and copper concentration (Cu).Using the optimized experimental conditions, the proposed procedure allows the determination these metals with detection limits of 0.18 μg L−1 for iron and 0.16 μg L−1 for lead. The effects of foreign ions on the pre-concentration procedure were also evaluated and the results demonstrated that this method could be applied for determination of iron and lead in several real samples. The proposed method was successfully applied to the analysis of seawater, urine, mineral water, soil and physiological solution samples. The concentrations of lead and iron achieved in these samples agree well with others data reported in the literature.  相似文献   
10.
建立了以PAN为吸附辅助剂,以活性碳为吸附剂,结合火焰原子吸收法测定地表水中痕量镉的方法.研制了以微量过滤器和医用注射器组成的分离富集装置;探讨了镉吸附解吸的最佳试验条件,并应用于实际环境水样中痕量镉的测定,回收率为98.25%~105.0%.该方法简化了分离富集程序,操作简单,迅速,能同时进行6~8个样品的分析测定,具备一定实用性.  相似文献   