首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   48篇
  免费   0篇
  国内免费   1篇
化学   42篇
数学   1篇
物理学   6篇
  2022年   1篇
  2021年   3篇
  2020年   2篇
  2019年   1篇
  2017年   1篇
  2012年   3篇
  2011年   1篇
  2010年   4篇
  2009年   10篇
  2008年   3篇
  2007年   9篇
  2006年   4篇
  2005年   1篇
  2004年   5篇
  2003年   1篇
排序方式: 共有49条查询结果,搜索用时 312 毫秒
1.
Both single-molecule detection (SMD) methods and miniaturization technologies have developed very rapidly over the last ten years. By merging these two techniques, it may be possible to achieve the optimal requirements for the analysis and manipulation of samples on a single molecule scale. While miniaturized structures and channels provide the interface required to handle small particles and molecules, SMD permits the discovery, localization, counting and identification of compounds. Widespread applications, across various bioscience/analytical science fields, such as DNA-analysis, cytometry and drug screening, are envisaged. In this review, the unique benefits of single fluorescent molecule detection in microfluidic channels are presented. Recent and possible future applications are discussed.Dedicated to the memory of Wilhelm Fresenius  相似文献   
2.
Investigating microfluidic flow profiles is of interest in the microfluidics field for the determination of various characteristics of a lab-on-a-chip system. Microparticle tracking velocimetry uses computational methods upon recording video footage of microfluidic flow to ultimately visualize motion within a microfluidic system across all frames of a video. Current methods are computationally expensive or require extensive instrumentation. A computational method suited to microparticle tracking applications is the robust Kanade–Lucas–Tomasi (KLT) feature-tracking algorithm. This work explores a microparticle tracking velocimetry program using the KLT feature-tracking algorithm. The developed program is demonstrated using pressure-driven and EOF and compared with the respective mathematical fluid flow models. An electrostatics analysis of EOF conditions is performed in the development of the mathematical using a Poisson's Equation solver. This analysis is used to quantify the zeta potential of the electroosmotic system. Overall, the KLT feature-tracking algorithm presented in this work proved to be highly reliable and computationally efficient for investigations of pressure-driven and EOF in a microfluidic system.  相似文献   
3.
An experimental study of a micromachined non-porous pillar array column performance under non-retentive conditions is presented. The same pillar structure has been fabricated in cyclo-olefin polymer (COP) chips with three different depths via hot embossing and pressure-assisted thermal bonding. The influence of the depth on the band broadening along with the already known contribution arising from the top and bottom cover plates has been studied. The experimental results exhibit reduced plate heights as low as 0.2, which are in agreement with the previous experimental work. Moreover, the constant values of the reduced Van Deemter expression are also in accordance with the previous studies. A more exhaustive study of the C-term band broadening is also presented, showing that comparing the space between the pillars with different open tubular rectangular channels offers a good estimation of the C-term band broadening that is obtained experimentally. These experimental results, hence, confirm that micromachined pillar array columns fabricated in COP can achieve the same performance as the ones fabricated in silicon for the presently studied pillar channel design.  相似文献   
4.
F.R.R. Teles 《Talanta》2008,77(2):606-623
Biosensors have witnessed an escalating interest nowadays, both in the research and commercial fields. Deoxyribonucleic acid (DNA) biosensors (genosensors) have been exploited for their inherent physico-chemical stability and suitability to discriminate different organism strains. The main principle of detection among genosensors relies on specific DNA hybridization, directly on the surface of a physical transducer. This review covers the main DNA immobilization techniques reported so far, new micro- and nanotechnological platforms for biosensing and the transduction mechanisms in genosensors. Clinical applications, in particular, demand large-scale and decentralized DNA testing. New schemes for DNA diagnosis include DNA chips and microfluidics, which couples DNA detection with sample pretreatment under in vivo-like hybridization conditions. Higher sensitivity and specificity may arise from nanoengineered structures, like carbon nanotubes (CNTs) and DNA/protein conjugates. A new platform for universal DNA biosensing is also presented, and its implications for the future of molecular diagnosis are argued.  相似文献   
5.
A flow injection micro-analyser with an integrated injection device and photometric detection is described. Channels measuring 205-295 μm depth by 265-290 μm maximum width were manufactured by deep UV lithography on two layers of urethane-acrylate oligomers-based photoresist. Hypodermic syringe needles (450 μm diameter) were connected to the channels for introduction of solutions into the system. Plastic optical fibres were connected to the ends of a 5.0 mm long channel, in order to conduct the light from and to a homemade photometer. The device has a total volume of 7.0 μL and three different sample volumes (0.09, 0.22 and 0.30 μL) can be inserted into the system by choosing the appropriate loop of the hydrodynamic injection approach. The micro-analyser, designed as a single line manifold, was evaluated by determining chloride in waters (mercuric thiocyanate method), and chromium (VI) in wastewater and total chromium in metallic alloys (diphenylcarbazide method). For chloride determination two micro-pumps were employed to impel the solutions, while for chromium determination this task was performed by a conventional peristaltic pump. The results obtained in all determinations did not differ significantly from the reference methods at a confidence level of 95%. In the chloride determination, a flow rate of 50 μL min−1 was used, providing a sample frequency of 45 injection h−1, generating ca. 0.7 mg of Hg(II) after an 8-h working day (ca. 20 mL of solution). This result suggests the potential of the micro-analyser towards the reduction of waste, following the philosophy of Green Chemistry.  相似文献   
6.
Optical sensing systems for microfluidic devices: a review   总被引:1,自引:0,他引:1  
This review deals with the application of optical sensing systems for microfluidic devices. In the “off-chip approach” macro-scale optical infrastructure is coupled, while the “on-chip approach” comprises the integration of micro-optical functions into microfluidic devices. The current progress of the use of both optical sensing approaches in microfluidic devices, as well as its applications is described. In all cases, sensor size and shape profoundly affect the detection limits, due to analyte transport limitation, not to signal transduction limitation. The micro- or nanoscale sensors are limited to picomolar-order detection for practical time scales. The review concludes with an assessment of future directions of optical sensing systems for integrated microfluidic devices.  相似文献   
7.
We use direct femtosecond laser writing to integrate optical waveguides into a commercial fused silica capillary electrophoresis chip. High-quality waveguides crossing the microfluidic channels are fabricated and used to optically address, with high spatial selectivity, their content. Fluorescence from the optically excited volume is efficiently collected at a 90° angle by a high numerical aperture fiber, resulting in a highly compact and portable device. To test the platform we performed electrophoresis and detection of a 23-mer oligonucleotide plug. Our approach is quite powerful because it allows the integration of photonic functionalities, by simple post-processing, into commercial LOCs fabricated with standard techniques. Figure Femtosecond laser written waveguides can selectively excite fluorescence in a microfluidic channel of a commercial lab-on-a-chip. A compact scheme for on-chip detection by laser induced fluorescence is applied to capillary electrophoresis of a 23-mer Cy3-labeled oligonucleotide  相似文献   
8.
This article reviews and highlights the current development of DNA-based bioanalytical microsystems for point-of-care diagnostics and on-site monitoring of food and water. Recent progresses in the miniaturization of various biological processing steps for the sample preparation, DNA amplification (polymerase chain reaction), and product detection are delineated in detail. Product detection approaches utilizing “portable” detection signals and electrochemistry-based methods are emphasized in this work. The strategies and challenges for the integration of individual processing module on the same chip are discussed.  相似文献   
9.
Magnetic microspheres (MMS) are useful tools for a variety of medical and pharmaceutical applications. Typically, commercially manufactured MMS exhibit broad size distributions. This polydispersity is problematic for many applications. Since the direct synthesis of monodisperse MMS is often fraught with technical challenges, there is considerable interest in and need associated with the development of techniques for size-dependent fractionation of MMS. In this study we demonstrated continuous size-dependent fractionation of sub-micron scale particles driven by secondary (Dean effect) flows in curved microfluidic channels. Our goal was to demonstrate that such techniques can be applied to MMS containing superparamagnetic nanoparticles. To achieve this goal, we developed and tested a microfluidic chip for continuous MMS fractionation. Our data address two key areas. First, the densities of MMS are typically in the range 1.5–2.5 g/cm3, and thus they tend be non-neutrally buoyant. Our data demonstrate that efficient size-dependent fractionation of MMS entrained in water (density 1 g/cm3) is possible and is not significantly influenced by the density mismatch. In this context we show that a mixture comprising two different monodisperse MMS components can be separated into its constituent parts with 100% and 88% success for the larger and smaller particles, respectively. Similarly, we show that a suspension of polydisperse MMS can be separated into streams containing particles with different mean diameters. Second, our data demonstrate that efficient size-dependent fractionation of MMS is not impeded by magnetic interactions between particles, even under application of homogeneous magnetic fields as large as 35 kA/m. The chip is thus suitable for the separation of different particle fractions in a continuous process and the size fractions can be chosen simply by adjusting the flow velocity of the carrier fluid. These facts open the door to size dependent fractionation of MMS.  相似文献   
10.
The development of microfluidic (lab-on-a-chip) technology requires local control of fluid flow in the microchannels. Conventional microvalve approaches involve moving parts and/or complicated fabrication techniques, which makes them unreliable and prevents inexpensive integration in microanalytical systems. We have developed a simple low cost method for regulating fluid flow in microchannels that is compatible with existing microfabrication techniques and eliminates the need for moving parts. We use an electrical signal to stimulate silver deposition on a thin solid electrolyte layer in a small region of a microchannel. Since fluid flow is dominated by the nature of the channel surface, the electrodeposited silver changes the fluid–surface interaction and the effect can be used to control the movement of the fluid. Increases in the contact angles of both water and methanol, by 20 and 27 respectively, have been demonstrated. Such changes in hydrophobicity are sufficient to retard or stop capillary or external pressure-driven fluid flow in typical microchannels.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号