首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   42篇
  免费   3篇
  国内免费   1篇
化学   3篇
力学   6篇
物理学   37篇
  2023年   1篇
  2017年   1篇
  2016年   3篇
  2015年   1篇
  2014年   12篇
  2013年   12篇
  2011年   2篇
  2009年   2篇
  2007年   2篇
  2005年   1篇
  2004年   3篇
  2003年   1篇
  2001年   2篇
  1999年   2篇
  1998年   1篇
排序方式: 共有46条查询结果,搜索用时 18 毫秒
1.
The glow curve structures for LiF:Mg,Cu,Na,Si TL detectors with various dopant concentrations and sintering temperatures were investigated for the improvement of the glow curve structure and sensitivity of the TL detector. The dopant concentrations were varied over the following ranges: Mg (0–0.25 mol%), Cu (0–0.07 mol%), Na and Si (0–1.5 mol%). With increasing Cu concentration, the intensity of the main peak was intensified and reached a maximum at a concentration of 0.05 mol%. The high-temperature peak was reduced. The dependency of the main peak intensity on the Mg concentration exhibits a sharp maximum at 0.2 mol%. The intensity of the high-temperature peak tends to rise slightly with increasing Mg concentration. It was found that the optimum concentrations of the dopants in the LiF:Mg,Cu,Na,Si TL material are Mg: 0.2 mol%, Cu: 0.05 mol%, Na and Si: 0.9 mol%. The dependency of the main peak intensity on sintering temperature exhibits a very sharp maximum at 830°C. The high-temperature peak was rapidly reduced after 825°C.  相似文献   
2.
A passive neutron dosemeter based on nuclear track detectors and TLD's was used in 1995 and 1997 on the MIR station and in Space Shuttle flights to MIR. As it is equipped with neutron converters and shieldings of different types the track detector system allows the neutron dose equivalent to be determined in rough energy intervals. The results of the measurements on the MIR station and in the Space Shuttle flights are presented and the influence of charged particles in the complex mixed radiation field in space is discussed. Improvements are possible by means of a new active neutron dosemeter which is under development at the PTB. First measurements with a prototype in the high-energy reference fields at CERN are presented and discussed.  相似文献   
3.
Thermoluminescence properties of lanthanum aluminum oxide (LaAlO3) crystals doped with optically active rare earth ions have been investigated for ultraviolet dosimetry purposes. Single crystals co-doped with 5.0 at.% of Ce3+ and 1.0 at.% of Dy3+ ions have two thermoluminescent (TL) peaks at 151 °C and 213 °C which can be sensitized after 1 h of UV exposure. The material shows very high TL output and linear response for UV spectral irradiance ranging from 0.04 to 1.20 mJ cm−2, that corresponds to 10 times the TL response of the Al2O3:C oxides. From 0.62 to 148.0 mJ cm−2 the dependence is linear with the logarithm of the spectral irradiance. The investigation demonstrates that LaAlO3:Ce,Dy crystals are very attractive to be investigated as UV dosimeters.  相似文献   
4.
A set of five 241Am–Be neutron sources are utilized in research and teaching at King Fahd University of Petroleum and Minerals (KFUPM). Three of these sources have an activity of 16 Ci each and the other two are of 5 Ci each. A well-shielded storage area was designed for these sources. The aim of the study is to check the effectiveness of shielding of the KFUPM neutron source storage area. Poly allyl diglycol carbonate (PADC) Nuclear track detectors (NTDs) based fast and thermal neutron area passive dosimeters have been utilized side by side for 33 days to assess accumulated low ambient dose equivalents of fast and thermal neutrons at 30 different locations around the source storage area and adjacent rooms. Fast neutron measurements have been carried out using bare NTDs, which register fast neutrons through recoils of protons, in the detector material. NTDs were mounted with lithium tetra borate (Li2B4O7) converters on their surfaces for thermal neutron detection via and nuclear reactions. The calibration factors of NTD both for fast and thermal neutron area passive dosimeters were determined using thermoluminescent dosimeters (TLD) with and without a polyethylene moderator. The calibration factors for fast and thermal neutron area passive dosimeters were found to be 1.33 proton tracks and 31.5 alpha tracks , respectively. The results show variations of accumulated dose with the locations around the storage area. The fast neutron dose equivalents rates varied from as low as up to whereas those for thermal neutron ranged from as low as up to . The study indicates that the area passive neutron dosimeter was able to detect dose rates as low as 7 and from accumulated dose for thermal and fast neutrons, respectively, which were not possible to detect with the available active neutron dosimeters.  相似文献   
5.
液体调谐减振器的分析   总被引:2,自引:0,他引:2  
本文利用Lamb变换,考虑液体的粘性,略去二维Navier-Stokes方程中的非线性预后,建立了频域内Navier-Stokres方程的边界积分表达式,完整地处理了边界条件(包括自由面边界条件和固壁边界条件)并且给出了液体随结构振动时的附加质量与阻尼的计算表达式。  相似文献   
6.
Abstract

LiNaSO4: Eu is a recently discovered thermoluminescence dosimetry (TLD) phosphor which is more sensitive than the widely used CaSO4:Dy. In this paper results are reported on TL glow curves, TL emission spectra and PL photoluminescence. These measurements help to understand the role of impurity and the mechanism of thermoluminescence in this phosphor.  相似文献   
7.
K2Ca2(SO4)3 microcrystalline pure, doped with Eu, Tb and co-doped with Eu, Tb was prepared by solid-state diffusion method. Nanoparticles of these phosphors were also prepared by the chemical co-precipitation method. The formation of the compounds was confirmed by XRD. The particle size was calculated by broadening of the XRD peaks using Scherrer's formula. The particle size of nanocrystalline powder material was approximately found to be around 20 nm. Thermoluminescence and photoluminescence were studied to see the effect of co-doping and particle size. Tb3+ co-doping decreases the intensity in the Eu2+ doped phosphor due to the energy transfer and multiple de-excitations through various radiative and non-radiative processes. The sensitivity of K2Ca2(SO4)3:Eu,Tb microcrystalline phosphor was around 15 times more than LiF-TLD 100 and 7 times more than CaSO4:Dy. A high temperature peak (615 K) was observed in case of the nanoparticles, which was attributed to a particle size induced phase transition. This was confirmed by differential scanning calormetry measurements. The decrease in the sensitivity in case of nanoparticles is attributed to the particle size effect i.e. volume to surface ratio. Theoretical analysis of the glow curves was done by glow curve convolution deconvolution method to calculate trapping parameters of various peaks.  相似文献   
8.
Rectangular tanks equipped with perforated screens and partly filled with water have been proposed as Tuned Liquid Dampers (TLDs) to mitigate the vibratory response of slender buildings. In a previous paper (Molin & Remy 2013)an experimental campaign was reported and its results compared with a numerical model, based on linearized potential flow theory. Good agreement was generally obtained for the added mass and damping coefficients. In these experiments the screen had numerous circular openings, 4 mm in diameter, and it was assumed in the numerical model that the screen created a pressure drop proportional to the square of the relative traversing velocity. In this subsequent paper complementary experiments are described where the screen openings are increased in size, keeping constant the open-area ratio, and varied in shapes (vertical slots then circular holes). As a result of the solid parts of the screen getting larger, inertia effects come into play resulting in a shift of the resonant frequencies of the odd sloshing modes. With a proper modification of the discharge law in the numerical model, ccounting for inertia effects, good agreement is recovered between experimental and numerical hydrodynamic coefficients.  相似文献   
9.
刘曙  狄红卫  姚曼虹 《光学技术》2017,43(6):542-546
为提升TLD目标跟踪算法的每帧处理速度,以达到在更高分辨率视频中跟踪目标的实时性要求,在TLD算法框架的基础上,提出了一种基于自适应尺度检测学习的目标跟踪算法(AS-TLD)。当跟踪目标成功时,选取当前帧跟踪到的目标尺度及几个相邻的尺度作为下帧检测目标时滑动窗口尺度的选取范围;而当跟踪失败时,则选取在TLD算法初始化阶段,根据跟踪目标及视频图像大小选定的尺度来保障长时间跟踪目标,从而有效减少了平均每帧扫描的窗口数量。实验结果表明,该方法不仅有效地降低了检测模块的检测时间,显著提高了整体算法速度,而且通过动态选取尺度,在一定程度使得TLD各个模块更加协调,跟踪精确度得到提升。  相似文献   
10.
This review of dosimetry for second cancer risk estimation introduces work carried out by Working Group 9 (WG9: Radiation Protection Dosimetry in Medicine) of the European Radiation Dosimetry Group (EURADOS). The work concentrates on the measurement of out-of-field doses in water phantoms using a variety of dosimeters to measure photon and neutron doses. These include optically stimulated luminescence (OSL), radiophotoluminescence (RPL) and thermoluminescence (TLD) dosimeters for photon dosimetry (together with ion chambers for reference measurements) and track etch and superheated emulsion detectors for neutron measurements. The motivation of WG 9 was to assess undue, non-target patient doses in radiotherapy and the related risks of second malignancy. Improvements in cancer treatment have increased survival times and thus increased incidence of second cancer may be expected in the future. In addition, increased whole body exposure may result from some developments in radiotherapy. This means that radiotherapy clinics will need to simulate their treatments in order to estimate and minimise doses to healthy tissues and organs. The proposed work is designed to generate a robust dataset of out-of-field dose measurements which can be used for the development and validation of dose algorithms.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号