全文获取类型
收费全文 | 436篇 |
免费 | 7篇 |
国内免费 | 3篇 |
专业分类
化学 | 435篇 |
物理学 | 11篇 |
出版年
2024年 | 1篇 |
2022年 | 5篇 |
2021年 | 17篇 |
2020年 | 12篇 |
2019年 | 4篇 |
2018年 | 11篇 |
2017年 | 6篇 |
2016年 | 11篇 |
2015年 | 15篇 |
2014年 | 8篇 |
2013年 | 36篇 |
2012年 | 34篇 |
2011年 | 29篇 |
2010年 | 32篇 |
2009年 | 41篇 |
2008年 | 19篇 |
2007年 | 27篇 |
2006年 | 27篇 |
2005年 | 26篇 |
2004年 | 29篇 |
2003年 | 12篇 |
2002年 | 5篇 |
2001年 | 3篇 |
2000年 | 5篇 |
1999年 | 10篇 |
1998年 | 5篇 |
1997年 | 4篇 |
1996年 | 7篇 |
1995年 | 4篇 |
1993年 | 1篇 |
排序方式: 共有446条查询结果,搜索用时 404 毫秒
1.
2.
3.
Medical grade PVC plasticised with polycaprolactone–polycarbonate (PCL–PC) was subjected to aqueous environments at different temperatures. The release profile during ageing was determined by solid phase microextraction (SPME) and GC–MS. At the same time changes in the surface composition due to, for example, migration of PCL–PC from the blend were followed by FTIR. Almost no changes in the material or its surface composition were observed during 98 days at 37 °C in water or phosphate buffer. Only trace amount of 6-hydroxyhexanoic acid the final hydrolysis product of PCL–PC was detected in the GC–MS chromatograms and the weight loss was negligible. Even when the ageing temperature was raised to 70 °C only minor increase in the amount of 6-hydroxyhexanoic acid was observed and the weight loss after 98 days was under 1%. Changes in the FTIR spectra indicating migration of PCL–PC towards the surface of the PVC/PCL–PC tubing were observed first after 70 days at 70 °C. Large increase in the hydrolysis rate of PCL–PC and almost complete depletion of PCL–PC from the blend was observed when the ageing temperature was raised to 100 °C. 相似文献
4.
Dimitrakakis E Haberhauer-Troyer C Abe Y Ochsenkühn-Petropoulou M Rosenberg E 《Analytical and bioanalytical chemistry》2004,379(5-6):842-848
The use of solid-phase microextraction (SPME) with gas chromatography coupled to microwave-induced plasma atomic-emission detection (GC–MIP-AED) is described for selenite [Se(IV)] speciation. Aqueous standards were derivatised with sodium tetraethyl- or tetrapropylborate and extracted by SPME. Headspace extraction of the ethyl and propyl derivatives was studied. Relevant experimental conditions were optimised, including conditions for derivatisation and extraction and those of gas chromatographic analysis. The limits of detection achieved for headspace sampling of derivatised Se(IV) were in the low ng mL–1 range for both ethylation and propylation. When the method was applied to analysis of selenite in selenised yeast reference material results were in good agreement with the indicated values. 相似文献
5.
Low molecular weight aromatic substances may migrate out from plastic packaging to their contents, especially if they consist of organic aqueous solutions or oils. It is, therefore, extremely important to be able to identify and quantify any migrated substances in such solutions, even at very low concentrations. We have in this work investigated and evaluated the use of solid-phase microextraction for the specific task of extraction from an organic aqueous solution such as a simulated pharmaceutical solution consisting of 10 vol.% ethanol in water. The goal was furthermore to investigate the possibility of simultaneously identifying and quantifying the substances in spite of differences in their chemical structures. Methods were developed and evaluated for extraction both with direct sampling and with headspace sampling. Difficulties appeared due to the ethanol in the solution and the minute amounts of substances present. We have shown that a simultaneous quantification of migrated low molecular weight degradation products of antioxidants using only one fibre is possible if the extraction method and temperature are adjusted in relation to the concentration levels of the analytes. Comparions were made with solid-phase extraction. 相似文献
6.
A new in-loop solid-phase microextraction (in-loop-SPME) technique, based on an aluminum capillary tube coupled to HPLC, is described for on-line isolation, concentration, and analysis of analytes from aqueous samples. L-Dopa and L-dopamine, in aqueous solutions, were selected as model compounds. The main conditions affecting extraction of the analytes from aqueous samples, desorption, injection, and chromatographic separation were investigated. The method is simple and reproducible. Using the proposed method, reliable determination of L-dopa and L-dopamine at parts-per-billion concentrations was achieved. The calibration plots were linear in the range of 2.5–1500 ng mL−1 with correlation coefficients of 0.999 and 0.998 for L-dopa and L-dopamine, respectively. The detection limits were 0.5–1 ng mL−1 with a relative standard deviation less than 4.1%. Concentration factors more than 100-fold were obtained for these compounds. 相似文献
7.
Investigation of Tomato Plant Defence Response to Tobacco Mosaic Virus by Determination of Methyl Salicylate with SPME-Capillary GC-MS 总被引:2,自引:0,他引:2
Headspace SPME was applied to investigation of tomato plant defence response to tobacco mosaic virus (TMV) by determination of compounds emitted from tomato plants at the extraction conditions of 25 °C and 15 min. It was found that TMV-inoculated tomato plant released large amount of methyl salicylate (MeSA) as response to TMV and MeSA concentration changed dramatically with time after inoculation. Gaseous MeSA as a signaling compound could induce in surrounding tomato plants to produce salicylic acid (SA) and synthesize and release MeSA. These results show that MeSA might be an airborne plant-signalling molecule in tomato plant response to TMV. The present method provided low detection limit of 2.0 ng L–1 and needed little sample preparation time (15 min), so the method makes it easy to find the critical times of tomato plant response to TMV by fast determination of MeSA released from tomato plant. 相似文献
8.
9.
A competitive enzyme-linked immunosorbent assay (ELISA) was developed for the quantitative detection of the insect growth regulator fenoxycarb. Polyclonal rabbit antisera, raised against protein conjugates of four haptenic derivatives of fenoxycarb, were utilized in immobilized antigen-based, competitive immunoassays. With ELISA systems that were both hapten- and carrier-heterologous, most antiserum titers fell in the range of 1:1000-1:30,000. Assay conditions, including concentrations of antisera and coating antigens, were optimized. The effect of pH, organic solvents, and various blocking agents was also investigated. A hapten-homologous and two hapten-heterologous indirect ELISAs allowed fenoxycarb determination in the range of 0.1-85 ng ml−1 with apparent IC50 values of 1.2-2.8 ng ml−1. Cross-reactivities with a number of compounds (e.g. pesticides of related structure, hapten synthesis intermediates, fenoxycarb metabolite, photodegradation products) were determined, and the assay proved highly selective for fenoxycarb. In particular, no significant interference was found with selected pyrethroid and juvenile hormone analog insecticides, phenoxyacetic acid herbicides, and photodegradation products of fenoxycarb. Using spiked water samples, assay performance was validated by SPME/GC-MS. 相似文献
10.
Extraction of capsaicins in aerosol defense sprays from fabrics 总被引:2,自引:0,他引:2
The use of aerosol defense sprays has increased as a means of self-defense and as a weapon in the commission of a crime. The residue of these sprays is often left behind as physical evidence on a victim's clothing or personal belongings. As the popularity of self-defense weaponry increases, so does the likelihood that it will be encountered in forensic casework. The extraction, recovery from fabrics, and identification of residue from defense sprays is described. The commonly used extraction method of liquid-liquid extraction is compared to solid phase microextraction (SPME) to recover capsaicin and dihydrocapsaicin from cotton swabs. The use of SPME resulted in lower limits of detection and greater recovery efficiency when compared to solvent extraction. SPME also provided more consistent recovery and less variability when compared to solvent extraction. The effect of use of various types of evidence packages on the preservation of this type of evidence is also reported. The collection and analysis of hand swabs after normal discharge of pepper spray canisters was studied indicating the low persistence of these compounds on the hands of the person conducting the spraying. Finally, the results of a real case whereby solvent-solvent extraction did not provide the necessary sensitivity for extracting the capsaicin compounds on the garments of a victim of an alleged spraying and the SPME extraction provided the recovery and identification of the compounds is also presented. 相似文献