首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   30篇
  免费   0篇
化学   30篇
  2015年   2篇
  2014年   3篇
  2013年   6篇
  2012年   4篇
  2011年   5篇
  2010年   4篇
  2009年   1篇
  2008年   1篇
  2005年   1篇
  2004年   2篇
  2003年   1篇
排序方式: 共有30条查询结果,搜索用时 31 毫秒
1.
This paper presents the development of a non-aqueous capillary electrophoresis method coupled to UV detection combined with multivariate curve resolution-alternating least-squares (MCR-ALS) to carry out the resolution and quantitation of a mixture of six phenolic acids in virgin olive oil samples. p-Coumaric, caffeic, ferulic, 3,4-dihydroxyphenylacetic, vanillic and 4-hydroxyphenilacetic acids have been the analytes under study. All of them present different absorption spectra and overlapped time profiles with the olive oil matrix interferences and between them. The modeling strategy involves the building of a single MCR-ALS model composed of matrices augmented in the temporal mode, namely spectra remain invariant while time profiles may change from sample to sample. So MCR-ALS was used to cope with the coeluting interferences, on accounting the second order advantage inherent to this algorithm which, in addition, is able to handle data sets deviating from trilinearity, like the data herein analyzed. The method was firstly applied to resolve standard mixtures of the analytes randomly prepared in 1-propanol and, secondly, in real virgin olive oil samples, getting recovery values near to 100% in all cases. The importance and novelty of this methodology relies on the combination of non-aqueous capillary electrophoresis second-order data and MCR-ALS algorithm which allows performing the resolution of these compounds simplifying the previous sample pretreatment stages.  相似文献   
2.
Diabetes, a multifunctional disease and a major cause of morbidity and mortality in the industrialized countries, strongly associates with the development and progression of atherosclerosis. One of the consequences of high level of glucose in the blood circulation is glycation of long-lived proteins, such as collagen I, the most abundant component of the extracellular matrix (ECM) in the arterial wall. Glycation is a long-lasting process that involves the reaction between a carbonyl group of the sugar and an amino group of the protein, usually a lysine residue. This reaction generates an Amadori product that may evolve in advanced glycation end products (AGEs). AGEs, as reactive molecules, can provoke cross-linking of collagen I fibrils. Since binding of low-density lipoproteins (LDLs) to the ECM of the inner layer of the arterial wall, the intima, has been implicated to be involved in the onset of the development of an atherosclerotic plaque, collagen modifications, which can affect the affinity of native and oxidized LDL for collagen I, can promote the entrapment of LDLs in the intima and accelerate the progression of atherosclerosis.In this study, open tubular capillary electrochromatography is proposed as a new microreactor to study in situ glycation of collagen I. The kinetics of glycation was first investigated in a fused silica collagen I-coated capillary. Dimethyl sulphoxide, injected as an electroosmotic flow marker, gave information about the charge of coating. Native and oxidized LDL, and selected peptide fragments from apolipoprotein B-100, the protein covering LDL particles, were injected as marker compounds to clarify the interactions between LDLs and the glycated collagen I coating. The method proposed is simple and inexpensive, since only small amounts of collagen and LDL are required. Atomic force microscopy images complemented our studies, highlighting the difference between unmodified and glycated collagen I surfaces.  相似文献   
3.
A capillary electrophoresis-mass spectrometry (CE-MS) method using sheath liquid electrospray ionization interfacing was studied and optimized for the analysis of intact basic proteins. To prevent protein adsorption, capillaries with a noncovalent positively charged coating were utilized. Capillaries were coated by subsequent rinsing with solutions of Polybrene, dextran sulfate and Polybrene. The coating proved to be fully compatible with MS detection, causing no background signals and ionization suppression. The composition of the sheath liquid and BGE was optimized using the model proteins α-chymotrypsinogen A, ribonuclease A, lysozyme and cytochrome c. A sheath liquid of isopropanol-water-acetic acid (75:25:0.1, v/v/v) at 2 μL min−1 resulted in optimal signal intensities for most proteins, but caused dissociation of the heme group of cytochrome c. Optimum protein responses were obtained with a BGE of 50 mM acetic acid (pH 3.0), which allowed a baseline separation of the test protein mixture. Several minor impurities present in the mixture could be detected and provisionally identified using accurate mass and a protein modification database. The selectivity of the CE-MS system was investigated by the analysis of acetylated lysozyme. Eight highly related species, identified as non-acetylated lysozyme and lysozyme acetylated in various degrees, could be distinguished. The CE-MS system showed good reproducibility yielding interday (three weeks period) RSDs for migration time and peak area within 2% and 10%, respectively. With the CE-MS system, determination coefficients (R2) for protein concentration and peak area were higher than 0.996, whereas detection limits were between 11 and 19 nM.  相似文献   
4.
During the last years (2000–2014), many publications concerning the forensic analysis of questioned documents have been published, and new techniques and methodologies are nowadays employed to overcome forensic caseworks. This article reviews a comprehensive collection of the works focused on this issue, including dating studies, the analysis of inks from pens and printers, the analysis of paper, the analysis of other samples related to questioned documents and studies on intersecting lines. These sections highlight the most relevant analytical studies by a wide range of analytical techniques. Separation and spectrometric techniques are critically discussed and compared, emphasizing the advantages and disadvantages of each one. Finally, concluding remarks on the research published are included.  相似文献   
5.
Haloacetic acids (HAAs) are by-products of the chlorination of drinking water containing natural organic matter and bromide. A simple and sensitive method has been developed for determination of ten HAAs in drinking water. The pressure-assisted electrokinetic injection (PAEKI), an on-line enrichment technique, was employed to introduce the sample into a capillary electrophoresis (CE)–electrospray ionization–tandem mass spectrometry system (ESI-MS/MS). HAAs were monitored in selected reaction monitoring mode. With 3 min of PAEKI time, the ten major HAAs (HAA10) in drinking water were enriched up to 20,000-fold into the capillary without compromising resolution. A simple solid phase clean-up method has been developed to eliminate the influence of ionic matrices from drinking water on PAEKI. Under conditions optimized for mass spectrometry, PAEKI and capillary electrophoresis, detection limits defined as three times ratio of signal to noise have been achieved in a range of 0.013–0.12 μg L−1 for ten HAAs in water sample. The overall recoveries for all ten HAAs in drinking water samples were between 76 and 125%. Six HAAs including monochloro- (MCAA), dichloro- (DCAA), trichloro- (TCAA), monobromo- (MBAA), bromochloro- (BCAA), and bromodichloroacetic acids (BDCAA) were found in tap water samples collected.  相似文献   
6.
Nanoparticle characterization is gaining importance in food technology, biotechnology, medicine, and pharmaceutical industry. An instrument to determine particle electrophoretic mobility (EM) diameters in the single-digit to double-digit nanometer range receiving increased attention is the gas-phase electrophoretic mobility molecular analyzer (GEMMA) separating electrophoretically single charged analytes in the gas-phase at ambient pressure. A fused-silica capillary is used for analyte transfer to the gas-phase by means of a nano electrospray (ES) unit. The potential of this capillary to separate analytes electrophoretically in the liquid phase due to different mobilities is, at measurement conditions recommended by the manufacturer, eliminated due to elevated pressure applied for sample introduction. Measurements are carried out upon constant feeding of analytes to the system. Under these conditions, aggregate formation is observed for samples including high amounts of non-volatile components or complex samples. This makes the EM determination of individual species sometimes difficult, if not impossible. With the current study we demonstrate that liquid phase electrophoretic separation of proteins (as exemplary analytes) occurs in the capillary (capillary zone electrophoresis, CE) of the nano ES unit of the GEMMA. This finding was consecutively applied for on-line desalting allowing EM diameter determination of analytes despite a high salt concentration within samples. The present study is to our knowledge the first report on the use of the GEMMA to determine EM diameters of analytes solubilized in the ES incompatible electrolyte solutions by the intended use of electrophoresis (in the liquid phase) during sample delivery. Results demonstrate the proof of concept of such an approach and additionally illustrate the high potential of a future on-line coupling of a capillary electrophoresis to a GEMMA instrument.  相似文献   
7.
A new CE method has been developed for the simultaneous separation of a group of parent phthalates. Due to the neutral character of these compounds, the addition of several bile salts as surfactants (sodium cholate (SC), sodium deoxycholate (SDC), sodium taurodeoxycholate (STDC), sodium taurocholate (STC)) to the separation buffer was explored showing the high potential of SDC as pseudostationary phase. However, the resolution of all the phthalates was not achieved when employing only this bile salt as additive, being necessary the addition of neutral cyclodextrins (CD) and organic modifiers to the separation media. The optimized cyclodextrin modified micellar electrokinetic chromatography (CD-MEKC) method consisted of the employ of a background electrolyte (BGE) containing 25 mM β-CD-100 mM SDC in a 100 mM borate buffer (pH 8.5) with a 10% (v/v) of acetonitrile, employing a voltage of 30 kV and a temperature of 25 °C. This separation medium enabled the total resolution of eight compounds and the partial resolution of two of the analytes, di-n-octyl phthalate (DNOP) and diethyl hexyl phthalate (DEHP) (Rs ~ 0.8), in only 12 min. The analytical characteristics of the developed method were studied showing their suitability for the determination of these compounds in commercial perfumes. In all the analyzed perfumes the most common phthalate was diethyl phthalate (DEP) that appeared in ten of the fifteen analyzed products. Also dimethyl phthalate (DMP), diallyl phthalate (DAP), dicyclohexyl phthalate (DCP), and di-n-pentyl phthalate (DNPP) were found in some of the analyzed samples.  相似文献   
8.
High quality assays are needed in drug discovery to reduce the high attrition rate of lead compounds during primary screening. Capillary electrophoresis (CE) represents a versatile micro-separation technique for resolution of enzyme-catalyzed reactions, including substrate(s), product(s), cofactor(s) and their stereoisomers, which is needed for reliable characterization of biomolecular interactions in free solution. This review article provides a critical overview of new advances in CE for drug screening over the past five years involving biologically relevant enzymes of therapeutic interest, including transferases, hydrolases, oxidoreductases, and isomerases. The basic principles and major configurations in CE, as well as data processing methods needed for rigorous characterization of enzyme inhibition are described. New developments in functional screening of small molecules that modulate the activity of disease-related enzymes are also discussed. Although inhibition is a widely measured response in most enzyme assays, other important outcomes of ligand interactions on protein structure/function that impact the therapeutic potential of a drug will also be highlighted, such as enzyme stabilization, activation and/or catalytic uncoupling. CE offers a selective platform for drug screening that reduces false-positives while also enabling the analysis of low amounts of complex sample mixtures with minimal sample handling.  相似文献   
9.
Non-absorbing alkyl ether sulfates (AES) can be separated using anthraquinone-2-carboxylic acid (AQCA) as a probe; however, absorbing alkyl benzene sulfonates (ABS), if present, interfere indirect detection of most AES oligomers. Overcoming of this interference, as well as the simultaneous characterisation and evaluation of AES, fatty acids and ABS, was accomplished by using a diode-array detector and the procedures here discussed. First, it was shown that ABS can be made undetectable by using a 9 nm wide and 227 nm centred charge-absorptivity null-balance detection window (NBDW), where its contribution to the absorbance cancels the dilution effects that its presence induces on the signal of the background chromophore (BGC). Two other procedures, not requiring any prior knowledge on the nature of the absorbing interference, were also addressed. In the first one, the NBDW procedure was emulated by software, by treating the time-wavelength data matrix stored during the experimental run, and in the second one, both the ABS and BGC spectra, and the concentration profiles of ABS and the non-absorbing solutes, were recovered by orthogonal projection approach (OPA) and alternating least squares (ALS). The OPA-ALS processing provided the deconvolved signals and the wavelengths required to implement the experimental and software-emulated NBDW procedures. A composite ABS spectrum and a mixed concentration profile of the non-absorbing solutes, that involves mutual ABS-BGC dilution effects are enclosed in the OPA-ALS straightforward solutions. The pure spectra and concentration profiles were finally retrieved by crossed orthogonalisation. For the NBDW procedures, the limits of detection (S/N = 3) for AES oligomers overlapped by 1500 microg ml(-1) ABS were of ca. 10 microM AES. Using decyl sulfate as internal standard, the relative standard deviation for AES in an ABS containing industrial sample was 4.5%. The procedures here described are useful to remove the interference produced by any absorbing solute when overlapped with indirectly detected solutes in both capillary electrophoresis (CE) and HPLC.  相似文献   
10.
The enantiomeric separation of chiral pharmaceuticals was investigated using dual systems with mixtures of cyclodextrin derivatives. The dual cyclodextrin systems, consisting of one highly-sulfated (α-, β-, and γ-HSCD) and one neutral cyclodextrin, i.e. either heptakis (2,3,6-tri-O-methyl)-β-CD (TMCD), heptakis (2,6-di-O-methyl)-β-CD (DMCD) or hydroxypropyl-β-CD (HPCD), are tested on 25 pharmaceutical compounds with different acid-basic properties (16 basics, 8 acids and 1 neutral). The influence on the separation of the type and concentration of neutral CD in highly-sulfated cyclodextrins-based dual selector systems, is investigated. For 11 of 16 basic compounds, a better separation is obtained with the CD mixtures compared to the use of only a highly-sulfated CD. Mixtures with TMCD give better results than those with DMCD and HPCD. Results showed that dual CD systems are useful to achieve and to optimise chiral separations of compounds not (sufficiently) separated with HSCDs alone. For example, ibuprofen was not resolved with α-, β- or γ-HSCD, but could be separated with the mixture 25 mM TMCD and 5% HS-β-CD. Based on the obtained results, a dual CD systems based separation strategy is defined.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号