首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   14篇
  免费   0篇
物理学   14篇
  2012年   1篇
  2011年   1篇
  2010年   2篇
  2000年   4篇
  1999年   2篇
  1996年   1篇
  1992年   1篇
  1988年   1篇
  1985年   1篇
排序方式: 共有14条查询结果,搜索用时 15 毫秒
1.
Effective denoising is vital for proper analysis and accurate quantitative measurements from magnetic resonance (MR) images. Even though many methods were proposed to denoise MR images, only few deal with the estimation of true signal from MR images acquired with phased-array coils. If the magnitude data from phased array coils are reconstructed as the root sum of squares, in the absence of noise correlations and subsampling, the data is assumed to follow a non central-χ distribution. However, when the k-space is subsampled to increase the acquisition speed (as in GRAPPA like methods), noise becomes spatially varying. In this note, we propose a method to denoise multiple-coil acquired MR images. Both the non central-χ distribution and the spatially varying nature of the noise is taken into account in the proposed method. Experiments were conducted on both simulated and real data sets to validate and to demonstrate the effectiveness of the proposed method.  相似文献   
2.
Adaptive anisotropic noise filtering for magnitude MR data   总被引:4,自引:0,他引:4  
Conventional noise filtering schemes applied to magnitude magnetic resonance (MR) images tacitly assume Gauss distributed noise. Magnitude MR data, however, are Rice distributed. Not incorporating this knowledge leads inevitably to biased results, in particular when applying such filters in regions with low signal-to-noise ratio. In this work, we show how the Rice data probability distribution can be incorporated so as to construct a noise filter that is far less biased.  相似文献   
3.
4.
5.
Nowadays, electroencephalography signals can be acquired from a patient lying in a magnetic resonance imaging system. It is even possible to acquire EEG signals during an MR imaging sequence. However, such EEG signals are severely distorted by artifacts originating from various effects (e.g., MR gradients, ECG). In this paper, a simple method is presented to reduce such artifacts. Thereby, special attention is focused on artifacts related to the patient's electrocardiogram. The method is shown to be effective, adaptive, and automatic.  相似文献   
6.
The construction of a high quality MR RF-antenna with incorporated EEG electrodes for simultaneous MRI and EEG acquisition is presented. The antenna comprises an active decoupled surface coil for receiving the MR signal and a whole body coil for transmitting the excitation RF pulses. The surface coil offers a high signal-to-noise ratio required for fMRI application and the whole body coil has a good B(1) excitation profile, which enables the application of homogeneous RF pulses. Non-invasive carbon electrodes are used in order to minimise the magnetic susceptibility artefacts that occur upon application of conductive materials. This dedicated set-up is compared to a standard set-up being a linear birdcage coil and commercially available Ag/AgCl electrodes. As the acquired EEG signals are heavily disturbed by the gradient switching, intelligent filtering is applied to obtain a clean EEG signal.  相似文献   
7.
Echo planar imaging (EPI) is an ultrafast magnetic resonance imaging (MRI) technique that allows one to acquire a 2D image in about 100 ms. Unfortunately, the standard EPI images suffer from substantial geometric distortions, mainly originating from susceptibility differences in adjacent tissues. To reduce EPI distortions, correction methods based on a field map, which is a map of the off-resonance frequencies, have been developed. In this work, a nonlinear least squares estimator is used to optimize the estimation of the field map of the B0 field. The model of the EPI and reference data includes parameters for the phase evolution, the complex magnitude, the relaxation of the MRI signal and the EPI-specific phase difference between odd and even echoes, and from these parameters, additional corrections might be computed. The reference data required to estimate the field map can be acquired with a modified EPI-sequence. The proposed method is tested on simulated as well as experimental data and proves to be significantly more robust against noise, compared to the previously suggested method.  相似文献   
8.
9.
We present high resolution 133Cs-13C double resonance NMR data and 13C-13C NMR correlation spectra of 13C enriched samples of the polymeric phase of CsC60. These data lead to a partial assignment of the lines in the 13C NMR spectrum of CsC60 to the carbon positions on the C60 molecule. A plausible completion of the assignment can be made on the basis of an ab initio calculation. The data support the view that the conduction electron density is concentrated at the C60 "equator," away from the interfullerene bonds.  相似文献   
10.
Diffusion weighted images (DWI), from which the corresponding diffusion tensor images (DTI) are estimated, are commonly acquired with anisotropic discretizations. Traditional methods to up-sample diffusion weighted images generally rely on scene-based interpolation and do not exploit structural information from the images. In this study, a DTI up-sampling framework is presented that incorporates the underlying anatomical shape information by means of non-rigid inter-slice registration. A strategy is proposed to reorient the interpolated tensor in order to maintain its proper orientation. Tests on phantom as well as on real data sets show that the proposed method is able to produce better results compared to scene based interpolation methods in terms of the accuracy of DWI/DTI interpolation, especially when diffusion tensor orientation is taken into account.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号