首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   79篇
  免费   3篇
  国内免费   1篇
化学   48篇
力学   11篇
数学   4篇
物理学   20篇
  2023年   2篇
  2021年   2篇
  2020年   2篇
  2019年   3篇
  2018年   5篇
  2017年   2篇
  2016年   4篇
  2015年   2篇
  2014年   3篇
  2013年   10篇
  2012年   13篇
  2011年   5篇
  2010年   3篇
  2009年   6篇
  2008年   4篇
  2007年   3篇
  2006年   3篇
  2005年   4篇
  2004年   2篇
  2002年   1篇
  1998年   1篇
  1994年   1篇
  1978年   1篇
  1974年   1篇
排序方式: 共有83条查询结果,搜索用时 31 毫秒
1.
In this research a Hg2+ ion biosensor was developed by combining Prussian blue (PB) with glucose oxidase (GOx) – an enzyme that can be inhibited by Hg2+ ions. An application of PB in the design of Hg2+ ion biosensor enabled detecting changes in hydrogen peroxide reduction current at low operational potential of 0.2 vs Ag|AgCl,KClsat. The described Hg2+ ion biosensor exhibited wide linear range from 27 μM to 247 μM of Hg2+ and higher maximal detectable concentration of Hg2+ than other GOx inhibition-based biosensors, making it convenient for the analysis of samples with high concentration of Hg2+ ions.  相似文献   
2.
We report an MS‐based workflow for identification of phosphorylated peptides from trypsinized protein mixtures and cell lysates that is suitable for high‐throughput sample analysis. The workflow is based on an in situ enrichment on matrix‐assisted laser desorption/ionization (MALDI) plates that were functionalized by TiO2 using automated ion landing apparatus that can operate unsupervised. The MALDI plate can be functionalized by TiO2 into any array of predefined geometry (here, 96 positions for samples and 24 for mass calibration standards) made compatible with a standard MALDI spotter and coupled with high‐performance liquid chromatography. The in situ MALDI plate enrichment was compared with a standard precolumn‐based separation and achieved comparable or better results than the standard method. The performance of this new workflow was demonstrated on a model mixture of proteins as well as on Jurkat cells lysates. The method showed improved signal‐to‐noise ratio in a single MS spectrum, which resulted in better identification by MS/MS and a subsequent database search. Using the workflow, we also found specific phosphorylations in Jurkat cells that were nonspecifically activated by phorbol 12‐myristate 13‐acetate. These phosphorylations concerned the mitogen‐activated protein kinase/extracellular signal‐regulated kinase signaling pathway and its targets and were in agreement with the current knowledge of this signaling cascade. Control sample of non‐activated cells was devoid of these phosphorylations. Overall, the presented analytical workflow is able to detect dynamic phosphorylation events in minimally processed mammalian cells while using only a short high‐performance liquid chromatography gradient. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   
3.
The probability density function (PDF) formulation of one scalar field undergoing diffusion, turbulent convection and chemical reaction is restated in terms of stochastic fields. These fields are smooth in space as they have a length scale similar to that of the PDF. Their evolution is described by a set of stochastic partial differential equations, which are solved using a finite volume scheme with a stochastic source term. The application of this methodology to a particular flow is shown first for a linear source term, with exact analytical solution for the mean and standard deviation, and then for a nonlinear reaction.  相似文献   
4.
5.
A highly sensitive and selective on‐line two‐dimensional reversed‐phase liquid chromatography/electrospray ionization–tandem mass spectrometry (2D‐LC‐ESI/MS/MS) method was developed and validated to determine rifaximin in rat serum by direct injection. The 2D‐LC‐ESI/MS/MS system consisted of a restricted access media column for trapping proteins as the first dimension and a Waters C18 column as second dimension using 0.1% aqueous acetic acid:acetonitrile as mobile phase in a gradient elution mode. Rifampacin was used as an internal standard. The linear dynamic range was 0.5–10 ng/mL (r2 > 0.998). Acceptable precision and accuracy were obtained over the calibration range. The assay was successfully used in analysis of rat serum to support pharmacokinetic studies. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   
6.
Ab initio density functional theory has been used to study the electronic band structure, k=0 (zone center) vibrational modes, and dielectric properties of the crystalline high-κ perovskite oxide SrZrO3. The frequencies of the k=0 normal modes are computed by the linear response technique and then grouped according to their symmetry. The dielectric intensity of each IR-active mode has been determined. It is found that the calculated orientationally averaged static dielectric constant ε0=21.49 is in good agreement with experiment.  相似文献   
7.
There is increasing interest in the usefulness of block copolymer micelles as drug delivery vehicles. However, their subcellular distribution has not been explored extensively, mostly because of the lack of adequately labeled block copolymers. In a previous study, we showed that fluorescently labeled block copolymer micelles entered living cells and co-localized with cytoplasmic organelles selectively labeled with fluorescent dyes. The details of the observed co-localizations were, however, limited by the resolution of the fluorescence approach, which is ca. 500 nm. Using transmission electron microscopy (TEM), we established time- and concentration-dependent subcellular distributions of gold-labeled micelles within human embryonic kidney (HEK 293) cells and human lung carcinoma (A549) cells. Gold particles were incorporated into poly(4-vinylpyridine)-block-poly(ethylene oxide) (P4VP21-b-PEO45) micelles. Data from dynamic light scattering (DLS) and TEM analyses revealed that the sizes of the gold particles ranged from 4 to 8 nm. The cells survived up to 24 h in the presence of low gold-labeled micelle concentrations (0.73 microg/mL), but cell death occurred at higher concentrations (i.e., kidney cells are more susceptible than lung cells). Over 24 h periods of equivalent exposure, lung cells internalized significantly more gold-incorporated micelles than kidney cells. Although micelles were added to the cell culture media as dispersed colloidal particles, the presence of serum in these media caused aggregation. These aggregates occurred mainly close to the cell plasma membrane at early times (5-10 min); however, at later times (24 h) aggregated particles were seen inside endosomes and lysozomes. Thus, gold-incorporated (labeled) micelles can serve as a valuable extension of the fluorescence approach to visualizing the localization of micelles in subcellular compartments, improving the resolution by at least 20-fold.  相似文献   
8.
High performance liquid chromatography (HPLC) and gas chromatography (GC) are introduced for analysis of polymer lubricants (stearamide, oleamide and erucamide). In the HPLC method, a reverse phase octadecylsilane (ODS) column along with acetonitrile/methanol (60:40) as a mobile phase were used. Detection of analytes was performed by a UV detector at 202 nm. The analysis time was less than 8 min. In the GC method, polar capillary column and flame ionization detector (FID) were used for separations and detection, respectively. The analysis time by GC was longer than HPLC and was about 30 min. Limits of detection, linear range and repeatability of both methods are similar, but determination of oleamide in real samples by HPLC method is difficult due to complexity of the initial part of HPLC chromatogram in polyethylene samples. That problem is not observed in the GC method. Detection limits in both methods for all analytes are lower than 0.003% which are much lower than the amount of lubricants in commercial polymers (0.05–0.2%).  相似文献   
9.
Cadmium sulfide (CdS) quantum dots (QDs) are formed within poly(ethylene oxide)-block-polystyrene-block-poly (acrylic acid) (PEO-b-PS-b-PAA) triblock copolymer aggregates of different architectures. These structures are obtained starting with the same ionically cross-linked primary micelles consisting of a cadmium acrylate core, a PS shell, and a PEO corona. One morphology is a worm-shaped micelle prepared in tetrahydrofuran (THF) in which the CdS QDs are surrounded by the PAA and aligned as a loose necklace in the PS matrix. The PEO serves as a corona around the PS rod. Another structure is a multicore spherical (ca. 50 nm) water soluble PS micelle, surrounded by PEO chains. The CdS particles within these two latter structures are formed by the reaction of cadmium ions present in the acrylate cores with hydrogen sulfide. In a third structure, the CdS QDs are located on the surface of PS micelles. A fourth spherical single-core micelle structure is postulated to exist in dilute THF solutions. The dimensions in all the aggregates can be controlled by the block length.  相似文献   
10.
Sulfonated polyacrylamide (SPAA) solutions were prepared and the effects of pressure, polymer concentration, and water temperature, pH and salinity on their rheological behavior were investigated using a concentric cylinder dynamic rheometer equipped with a high pressure cell. According to the rheological flow curves the shear stress of SPAA solutions increased less than in proportion to their shear rates; that is, a shear thinning effect occurred. For polymer solutions containing 15,000 ppm of SPAA, shear viscosity, and stress were nearly insensitive to pressure. However, the shear viscosity and stress of SPAA solutions were affected by temperature and this effect was more evident at lower pressure. The flow curves indicated the shear viscosity and stress of the samples increased with increasing SPAA concentration and pH of the water, but were decreased with increasing water salinity and temperature.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号