首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   67篇
  免费   7篇
化学   68篇
力学   1篇
数学   1篇
物理学   4篇
  2023年   2篇
  2021年   2篇
  2020年   4篇
  2018年   3篇
  2016年   1篇
  2014年   5篇
  2013年   5篇
  2012年   1篇
  2011年   3篇
  2010年   6篇
  2009年   12篇
  2008年   6篇
  2007年   3篇
  2006年   4篇
  2005年   4篇
  2004年   7篇
  2003年   1篇
  2002年   1篇
  2001年   2篇
  1995年   1篇
  1992年   1篇
排序方式: 共有74条查询结果,搜索用时 31 毫秒
1.
We have prepared spherical non-agglomerated silver nanoparticles by an evaporation–condensation–dilution/cooling technique. Silver was evaporated from a crucible in a tubular flow reactor. A porous tube diluter was used to quench the carrier gas at the outlet of the reactor to enhance the formation of small particles and to suppress agglomeration and other particle growth mechanisms. The number size distribution of the prepared particles was measured with a differential mobility analyser–condensation nucleus counter combination and the size and the shape of the particles were analysed with transmission electron microscope. The system was modelled using a sectional aerosol dynamics computer code to estimate the importance of different aerosol processes. In all conditions the particles obtained were non-agglomerated and spherical. The mean particle diameter varied from 4 to 10-nm depending on boundary conditions. From the modelling studies it can be concluded that the nucleation rate is the most important parameter controlling the final particle size.  相似文献   
2.
Gas chromatography/ion trap mass spectrometry with in-source ionization and dissociation was used in positive-ion chemical ionization (PICI) mode for the determination of organophosphate triesters in indoor air. These compounds are widely used as additive flame retardants and plasticizers in different types of materials and have become ubiquitous pollutants in indoor environments. When using collision-induced dissociation in PICI mode the fragmentation of the organophosphate triesters can be performed in a more controllable way than in electron ionization (EI) mode. The developed selected-reaction monitoring method provided high selectivity for the investigated compounds. For 8-h air measurements (corresponding to 1.5 m3 of sampled air) the limit of detection of the method was determined to be in the range 0.1-1.4 ng m(-3), which is comparable with nitrogen-phosphorus detection and about 50-fold lower than when using EI in selected-ion monitoring mode. The presented method was applied to samples from three common indoor environments, in which a number of organophosphate triesters were identified and quantified. The dominating compound was found to be tris(2-chloropropyl) phosphate, which occurred at levels up to 0.8 microg m(-3).  相似文献   
3.
A cylindrical chemosorptive denuder in series with a glass fibre filter has been evaluated for sampling toluene diisocyanate (TDI) aerosols. The sampler is designed for measuring personal exposure to diisocyanates. Several denuder coatings and derivatising reagents were investigated. Dimethylpolysiloxane (SE-30) and 5% phenyl dimethylpolysiloxane (SE-54) with either dibutylamine (DBA) or dipentylamine (DPeA) as derivatising reagents yielded the lowest vapour breakthrough (the amount (%) of the vapour that passes through the denuder), close to values predicted by theory. Immobilisation of the SE-30 denuder coating by in-situ cross-linking yielded comparable results. With an SE-30/DBA-coated denuder operating within an airflow range of 100–500 mL min–1, the phase separation was shown to be consistent with theoretical predictions derived by use of the Gormley–Kennedy equation. This provides a means of calculating the vapour breakthrough and correcting experimentally obtained values with regard to vapour–particulate phase distribution, suggesting that the denuder can provide accurate phase-distribution measurements. The SE-30/DBA denuder can be used over a concentration range spanning nearly six orders of magnitude. Its capacity is sufficient to perform 15-min exposure measurements of a TDI aerosol with air concentrations as high as 1,700 g m–3, 40 times higher than the Swedish occupational exposure limit (OEL). At the other end of the range, the estimated limit of detection (LOD) was less than 2 ng m–3 for both the vapour and the aerosol phases when LC–ESI–MS–MS was used for chemical analysis.Electronic Supplementary Material Supplementary material for this article is available at  相似文献   
4.
ABSTRACT

D-Mannitol was used as precursor for the synthesis of acyclic C 2 symmetric potential HIV-1 protease inhibitors. The 1- and 6-hydroxy groups of D-mannitol were substituted by -NHBoc, -NHValZ, -SAr, -SOAr and -SO2Ar and the 2-and 5-hydroxy groups were benzylated. In some products one of the central hydroxyl groups was either inverted or deoxygenated. Despite a close structural similarity to previously published inhibitors none of the products showed significant inhibitory activity against HIV-1 protease.

  相似文献   
5.
By displaying different O‐glycans in a multivalent mode, mucin and mucin‐like glycoproteins are involved in a plethora of protein binding events. The understanding of the roles of the glycans and the identification of potential glycan binding proteins are major challenges. To enable future binding studies of mucin glycan and glycopeptide probes, a method that gives flexible and efficient access to all common mucin core‐glycosylated amino acids was developed. Based on a convergent synthesis strategy starting from a shared early stage intermediate by differentiation in the glycoside acceptor reactivity, a common disaccharide building block allows for the creation of extended glycosylated amino acids carrying the mucin type‐2 cores 1–4 saccharides. Formation of a phenyl‐sulfenyl‐N‐Troc (Troc=trichloroethoxycarbonyl) byproduct during N‐iodosuccinimide‐promoted thioglycoside couplings was further characterized and a new methodology for the removal of the Troc group is described. The obtained glycosylated 9‐fluorenylmethoxycarbonyl (Fmoc)‐protected amino acid building blocks are incorporated into peptides for multivalent glycan display.  相似文献   
6.
7.
A simple and sensitive method was developed using hydrophilic interaction liquid chromatography coupled to tandem mass spectrometry for determination of monosaccharides liberated from marine polysaccharides by acidic hydrolysis. Optimal separation of diastereomeric monosaccharides including hexoses, pentoses, and deoxyhexoses was achieved using an aminopropyl bonded column with mobile phase containing ternary solvents (acetonitrile/methanol/water) in conjunction with MS/MS in SRM mode. Mechanisms for fragmentation of deprotonated monosaccharides with regard to cross-ring cleavage were proposed. Matrix effects from coeluting interferences were observed and isotopic-labeled internal standard was used to compensate for the signal suppression. The method demonstrated excellent instrumental limits of detection (LOD), ranging from 0.7 to 4.2 pg. Method LODs range from 0.9 to 5.1 nM. The proposed method was applied to the analysis of polysaccharides in seawater collected from the open leads of the central Arctic Ocean in the summer of 2008.  相似文献   
8.
A shot in the arm for cancer treatment: Two MUC1 tetanus toxoid vaccines were synthesized and induced a strong immune response in mice. The antibodies elicited by the vaccines show a high selectivity for the tumor cells in mammary carcinoma tissues and also distinguish between tumor tissues at different stages.  相似文献   
9.
10.
Chemical yield determination can be a limiting source to the combined standard uncertainty in measurements of radionuclides. Therefore, the combined standard uncertainties in yield determination in the measurement of radioactive strontium using two methods were evaluated. The two methods compared were the measurement of stable strontium by atomic absorption spectrometry (AAS) and the gamma spectrometric measurement of 85Sr. The evaluation showed that using gamma spectrometry for yield determination can reduce the combined standard uncertainty by a factor of three compared to AAS. The expanded uncertainties of AAS and gamma spectrometry were calculated to be 10% and 3.3% (k = 2), respectively.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号