排序方式: 共有33条查询结果,搜索用时 15 毫秒
1.
Bekzat ABDIKADYR Alp KILI Onur ALEV Serkan BÜYÜKK
SE Zafer Ziya
ZTÜRK 《Turkish Journal of Chemistry》2021,45(2):295
Pristine and WO3 decorated TiO2 nanorods (NRs) were synthesised to investigate n-n-type heterojunction gas sensing properties. TiO2 NRs were fabricated via hydrothermal method on fluorine-doped tin oxide coated glass (FTO) substrates. Then, tungsten was sputtered on the TiO2 NRs and thermally oxidised to obtain WO3 nanoparticles. The heterostructure was characterised by X-ray diffraction (XRD), scanning electron microscopy (SEM), and energy-dispersive X-ray (EDX) spectroscopy. Fabricated sensor devices were exposed to VOCs such as toluene, xylene, acetone and ethanol, and humidity at different operation temperatures. Experimental results demonstrated that the heterostructure has better sensor response toward ethanol at 200 °C. Enhanced sensing properties are attributed to the heterojunction formation by decorating TiO2 NRs with WO3. 相似文献
2.
Ersen G
KTÜRK 《Turkish Journal of Chemistry》2020,44(5):1285
In this study, the catalytic activity and stability of flowerlike hybrid horseradish peroxidase (HRP) nanobiocatalyst (HRP-Cu 2+ ) obtained from Cu 2+ ions and HRP enzyme in the polymerization reaction of guaiacol were analyzed. We demonstrated that HRP-Cu 2+ and hydrogen peroxide (H 2 O 2 ) initiator showed significantly increased catalytic activity and stability on the polymerization of guaiacol compared to that of free HRP enzyme. Poly(guaiacol) was observed with quite high yields (88%) and molecular weights (38,000 g/mol) under pH 7.4 phosphate-buffered saline (PBS) conditions at 60 °C with 5 weight% of HRP-Cu 2+ loading. HRP-Cu 2+ also shows very high thermal stability and works even at 70 °C reaction temperature; free HRP enzyme denatures at that temperature. Furthermore, HRP-Cu 2+ provided considerable repeated use and showed some degree of catalytic activity, even after the fourth recycle, in the polymerization of guaiacol. 相似文献
3.
shak ERK Gzde KILI Elif
ZTÜRK engül Alpay KARAOLU Nurettin YAYLI 《Turkish Journal of Chemistry》2020,44(6):1655
The volatile components of essential oil (EO), SPME, and SPME of solvent extracts ( n -hexane, methanol, and water) obtained from fresh Serapias orientalis subsp. orientalis ( Soo ) were analyzed by GC-FID/MS. EO of Soo gave 11 compounds in the percentage of 99.97%; capronaldehyde (37.01%), 2-( E )-hexenal (23.19%), and n -nonanal (19.05%) were found to be major constituents. SPME GC-FID/MS analyses of fresh plant and solvent extracts of Soo revealed 7, 12, 7, and 4 compounds within the range of 99.7% to 99.9%. Limonene (76.5%, 41.7%, and 61.3%) was the major compound in SPMEs of the n -hexane and methanol extracts. α -Methoxy- p -cresol (52.9%) was the main component in its water extract. The antimicrobial activity of EO and the solvent extracts of Soo were screened against 9microorganisms. EO showed the best activity against Mycobacterium smegmatis , with 79.5 µg/mL MIC value. The n -hexane, methanol, and water extracts were the most active against the Staphylococcus aureus within the range of 81.25–125.0 µg/mL (MIC). IC 50 values for the lipase enzyme inhibitory activity of EO and solvent extracts ( n -hexane, methanol, and water) were determined to be 59.87 µg/mL, 64.03 µg/mL, 101.91 µg/mL, and 121.24 µg/mL, respectively. 相似文献
4.
Background
Pentachloronitrobenzene (PCNB) and hexachlorobenzene (HCB) are highly toxic and widespread in every environmental compartment. Some of metabolic products such as amino/nitro containing chlorinated aromatic compounds can be determined by gas chromatography coupled with electron capture detector (GC-ECD). However, it is difficult to identify some of chlorophenolic and chloroquinolic intermediates produced from PCNB and HCB by the above mentioned technique. Therefore, for analysis of these compounds and their metabolites, we have developed a high performance liquid chromatography (HPLC) based method.Results
The extraction of PCNB and HCB from soil and minimal salt medium was carried out with ethyl acetate and hexane respectively with good recoveries (98% for PCNB and 97% for HCB). The validation of the proposed extraction and HPLC method was done by analysis of PCNB and HCB biodegradation and their metabolites identification from anaerobic enriched soil samples.Conclusion
A rapid, sensitive and simple HPLC based analytical method was developed for the analysis of PCNB, HCB and their possible intermediates. 相似文献5.
Summary Microscopic scattering centers in as-grown AgGaS2 were investigated by optical and scanning electron microscopy. The defects consisted of rectangular platelets lying in the
(100) and (010) planes. Their longest dimension (up to 100 μm) was parallel to the [001]-direction. Their shorter dimension
was parallel to the [100] and [010] directions, respectively. The scattering centers were usually fractions of a micrometer
thick and did not appear to have a different composition than the matrix phase according to results by energy-dispersive analysis.
The defects can be eliminated by annealing in Ag2S or quenching from elevated temperature, which suggests that the defects may themselves consist of a two-phase region, part
of which should be Ga2S3-rich, where rodlike or platelike second-phase particles are embedded in the matrix. The quantity and the size of this second
phase make a definitive compositional analysis difficult.
Paper presented at the ?V International Conference on Ternary and Multinary Compounds?, held in Cagliari, September 14–16,
1982. 相似文献
6.
We consider the thermoelastic plate under the presence of along range memory. We find uniform rates of decay (in time)of the energy, provided that suitable assumptions on the relaxationfunctions are given. Namely, if the relaxation decays exponentiallythen the first order energy also decays exponentially. Whenthe relaxation g satisfies -c1g(t)1+1/p g'(t) -cog(t)1+1/p; and g,g1-1/p L1 (R) withp > 2 then the energy decays as 1/(1+t)p. A new Liapunov functionalis built for this problem. 相似文献
7.
Using integer and noninteger n-Slater type orbitals in single- and double-zeta approximations, the Hartree-Fock-Roothaan calculations were performed for the ground states of first ten cationic members of the isoelectronic series of He atom. All the noninteger parameters and orbital exponents were fully optimized. In the case of noninteger n-Slater type orbitals in double zeta basis sets, the results of calculations obtained are more close to the numerical Hatree-Fock values and the average deviations of our ground state energies do not exceed 2×10-6 hartrees of their numerical results. 相似文献
8.
9.
ÜMMÜHAN OCAK HALIT KANTEKIN YAŞAR GÖK H. BASIR ŞENTÜRK 《Journal of inclusion phenomena and macrocyclic chemistry》2006,55(1-2):87-91
The selective liquid–liquid extraction of various transition metal cations from the aqueous phase to the organic phase was carried out using a 14-membered N2O2S2-macrobicycle. Metal picrates such as Pb2+, Co2+, Zn2+, Ni2+,Cu2+ and Cd2+ were used in this extraction studies. It was found that the ligand showed moderate selectivity towards Pb2+ only among the other metals. The extraction constant (log K
ex) was determined to be 13.8 for Pb2+ complex. 相似文献
10.
Development of a new lectron-recoil ion/photon coincidence setup for investigating some of the electron induced collision processes, such as electron bremsstrahlung, electron backscattering,
innershell excitation and multiple ionization of target atoms/molecules in bombardment of electrons having energies from 2.0
keV to 30.0 keV with solid and gaseous targets is described. The new features include the use of a compact multipurpose scattering
chamber, a time-of-flight spectrometer for detection of multiply charged target ions, a 45°-parallel plate electrostatic analyzer
for measuring energy and angle of the ejected electrons, a room temperature high resolution Si-PIN photo diode X-ray detector
for counting the collisionally induced photons, a coincidence data acquisition system consisting of a 200 MHz Pentium based
8K-multichannel analyzer and a standard network of a fast/slow coincidence electronics. In particular, the details of design,
fabrication and assembly of indigenous components employed in the setup are presented. Selected experiments planned with the
setup are mentioned and briefly discussed. A report on performance, optimization, efficiency, time resolution etc. of the
time-of-flight (TOF) spectrometer and that of the 45°-parallel plate electrostatic analyzer (PPEA) is presented. Test spectra
of electron-recoil ion coincidences, energy distribution of ejected electrons and characteristic plus non-characteristic X-ray
spectrum are illustrated to exhibit the satisfactory performance of the developed setup. 相似文献