Meropenem, a representative β-lactam antibiotic, is widely used to treat complicated and serious infections. Therefore, it is of great significance to monitor the plasma drug concentration for individualized antimicrobial therapy. This study first describes the development and validation of high-performance liquid chromatography–tandem mass spectrometry cubed method for monitoring meropenem in human plasma. Protein precipitation with methanol and a chromatographic analysis time of 7 min make this method simple and of high throughput. Meropenem was extracted from human plasma with recoveries >94.1%. Calibration curves were linear (R2 > 0.995) in the concentration range of 0.5–50 μg/mL. Overall accuracy and precision did not exceed 8.0% as well as no significant matrix effect was observed. The novelty of this method is that the triple-stage mass spectrometry technology improves the selectivity and sensitivity. A comparison of the presented method and traditional liquid chromatography–tandem mass spectrometry method was assessed in 44 patients treated with meropenem and Passing–Bablok regression coefficients and Bland–Altman plots showed that no significant difference between the two methods. So the triple-stage mass spectrometry method developed in this study is appropriate and practical for the monitor of meropenem in the daily clinical laboratory practice. 相似文献
Nonlinear Dynamics - The perovskite solar cell (PSC) is one of the most promising photovoltaic candidates along with the highly increasing demand for green electricity. One of the main concerns... 相似文献
Catalysis Surveys from Asia - The catalytic performances and mechanism differences of model catalysts Cu–SSZ-13 and Fe–SSZ-13 with similar metal content and Si/Al ratio were compared.... 相似文献
Science China Chemistry - A light-induced, nickel-catalyzed three-component arylsulfonation of 1,3-enynes in the absence of photocatalyst is reported. This methodology exhibited mild conditions,... 相似文献
The microfluidic chip for nucleic acid detection in vitro is an essential application of microfluidic technology to the process of in vitro diagnosis. The 90° bend microchannels in chip designed for facilitating assay reagent delivery may cause reagent residues and cast mutual contamination between detection reagents, which significantly affects the detection accuracy. In this paper, a two-dimensional gas–liquid two-phase flow model is constructed to simulate the liquid residue phenomenon. Using the results of simulation, the residual liquid generation can be observed and the area of residual liquid can be obtained. The accuracy of the numerical simulation is verified by comparison with the experimental results. The effects of the fillet radius R, the diameter ratio d1/d2 of the vertical to horizontal sections, the flow velocity v, and the surface roughness Ra on the residual amount are studied. We find that the fillet radius is inversely proportional to the residual amount within the range v = 20–100 mm/s and there is almost no liquid residue in the channel when the radius increases to R = 1 mm. When the channel diameter ratio d1/d2 increases, the liquid residual amount also increases by approximately 98%. The increased surface roughness Ra significantly increases the residual amount. The results of this study provide a reference for the optimal design of microchannels on chips.