首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   5篇
  免费   3篇
化学   2篇
数学   1篇
物理学   5篇
  2022年   1篇
  2017年   1篇
  2016年   2篇
  2006年   2篇
  1994年   1篇
  1988年   1篇
排序方式: 共有8条查询结果,搜索用时 15 毫秒
1
1.
The optimum image processing result of low-frequency filtering was obtained when LiNbO3:Fe crystal as a spatial filter was placed at a certain position behind the spatial-frequency spectral plane of an optical Fourier transform system, which corresponds to the minimum transmittance ratio in Z-scan curve. The experimental results show that self-defocusing due to photorefractive negative-lens effect is the main factor responsible for the low- frequency filtering.  相似文献   
2.
在各类光学系统设计过程中,由于实验系统对于光学器件的透反射率要求不同,需要确定光学器件的透反射率。本文设计了一种对光学器件的透反射率进行精准测量及标定的系统,该系统通过对激光光源进行声光调制,使得激光输出功率的稳定度显著提高,避免了测量时光源不稳定带来的较大误差。实验结果表明,该系统能够稳定光源输出功率,稳定度维持在0.05%/h,甚至更高的水平,满足了光学器件透反射率测量的误差小,精度高等要求。  相似文献   
3.
固相微萃取气相色谱法(SPME-GC)测定水体中邻苯二甲酸酯   总被引:9,自引:0,他引:9  
选用85μm PA纤维,考证了萃取温度、萃取时间、搅拌、离子强度及解析时间等影响因素,最后确立了65℃萃取温度、60min萃取时间、稳定的磁力搅拌、5min解析时间、用带电子捕获检测器的毛细管气相色谱(CGC—ECD)分离测定、外标标准曲线法定量分析水体中邻苯二甲酸酯(PAEs)的方法。该方法具有较好的精密度(RSD≤16%)和较低的检出限(DLDBP=0.003μg/L,DLDEDEHP=0.05μg/L),水样加标回收率在70%~130%之间。用该法测定了长江水样、太湖水样、自来水及蒸馏水的PAEs含量,DBP在0.1~0.4μg/L,DEHP在0.2~1.2μg/L,DMP、DEP、DOP均未检测到。  相似文献   
4.
为准确测量近红外波段单光子探测器量子效率,搭建了基于自发参量下转换效应的测量系统.系统利用中心波长为518nm的脉冲激光泵浦周期极化磷酸氧钛钾晶体,通过自发参量下转换过程产生相关光子对,分别测量了Si和InGaAs雪崩光电二极管单光子探测器在778nm和1 550nm波长点的量子效率,并对测量不确定度进行了分析.实验表明,该装置可以测量近红外单光子探测器量子效率参量,测量不确定度均优于1%.  相似文献   
5.
介绍了溯源至低温辐射计的紫外绝对光谱响应度测量装置,对硅陷阱探测器在三个激光波长点进行了绝对光谱响应度校准实验.测量了硅陷阱探测器的空间均匀性和非线性系数,分析了影响测量准确度的各不确定度分量.实验表明:硅陷阱探测器在紫外波段266、325、379 nm三个激光波长点处的绝对光谱响应度测量扩展不确定度分别为0.19%、0.14%、0.11%,可作为紫外波段光辐射功率基准保持和传递的标准探测器,用于提高紫外波段光谱辐射度的校准能力.  相似文献   
6.
Xi-Hang Yang 《中国物理 B》2022,31(9):94206-094206
We present a cascaded nonlinear spectral broadening scheme for Nd-doped lasers, featuring with long pulse duration and high average power. This scheme is based on two multi-pass cells (MPCs) and one multiple-plate supercontinuum generation (MPSG), and the numerical investigation is driven by a home-made Nd-doped fiber laser with 12 ps pulse duration, 50 kHz repetition rate and 100 W average power. The MPC-based first two stages allow us to broaden the pulse spectrum to 4 nm and 43 nm respectively, and subsequently, the MPSG-based third stage allows us to reach 235 nm spectral bandwidth. This broadened spectrum can support a Fourier-transfer-limited pulse duration of 9.8 fs, which is shorter than three optical cycles. To the best of our knowledge, it is the first time to demonstrate the possibility of few-cycle pulses generation based on the 10 ps level Nd-doped lasers. Such few-cycle and high average power laser sources should be attractive and prospective, benefiting from the characteristics of structure compact, low-cost and flexibility.  相似文献   
7.
原子荧光光谱法同时测定农产品中砷和汞   总被引:14,自引:2,他引:12  
研究了用AFS-920型双道原子荧光光度计同时测定食品中砷和汞的方法。方法快速、相对标准偏差小于10%,砷和汞的回收率分别为88.0-107.0%和89.8%-114.0%,符合国标对农产品安全质量检测的要求。  相似文献   
8.
从一九八三年到一九八六年,四部委(国家教委牵头,会同卫生部、国家体委、国家民委)联合搞的中国学生体质与健康调查研究。作无论是在抽样范围之广,涉及民族之多,样本数量之大,还是在原始数据的采集可靠性方面,均称世界范围内的大规模、高水平体质调研工作.对调研得到的宝贵原始数据进行统计、分析、研究,无疑是对人类人体工程研究的一个贡献,具有广泛的社会效益. 本文就这次体质与健康调研工作的原始数据采集中的抽样范围在采集中的质量控制,分析处理中的指标体系、处理方法及得到的成果进行简单介绍.着重就我国现阶段体质与健康调研分析处理工作中存在的问题提出来供大家研究,以提高体质与健康统计分析的理论水平.  相似文献   
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号