排序方式: 共有33条查询结果,搜索用时 250 毫秒
1.
2.
本文利用252Cf快裂变室和多参数数据采集系统,逐事例的同时记录了自发裂变中子和瞬发伽马的飞行时间(TOF),脉冲形状甄别(PSD)和反冲能量(RE,裂变中子是通过测量反冲质子;瞬发伽马是通过测量康普顿反冲电子)三维信息.详细介绍了通过离线数据分析完全扣除三维信息中的伽马事例贡献,以获得Φ50.8 mm×50.8 mm的BC501A液闪探测器的相对探测效率和响应函数的方法.在不通过探测器响应函数进行数据转换的条件下,利用中子的能量直接确定了中子的有效测量阈值.得到的中子
关键词:
252Cf快裂变室')" href="#">252Cf快裂变室
BC501A液闪探测器
相对探测效率
响应函数 相似文献
3.
The multilayer (ML) mirror with high-reflectivity (HR) at a specific emission line of 19.5 nm (Fe line) and low-reflectivity (LR) at 30.4 nm (He line) is needed to be designed and fabricated for observing the image of sun. Based on a variety of optimizations utilized different structures, the design is performed and the final results demonstrate that the reflectivity at 30.4 nm does not achieve minimum value when the reflectivity at 19.5 nm reaches the maximum value. The tradeoff should be done between the HR at 19.5 nm and LR at 30.4 nm. One optimized mirror is fabricated by direct current magnetron sputtering and characterized by grazing-incident X-ray diffraction (XRD) and synchrotron radiation (SR). The experimental results demonstrate that the ML achieves the reflectivity of 33.3% at 19.5 nm and of 9.6× 10-4 at 30.4 nm at the incident angle of 13°. 相似文献
4.
钍快中子裂变反应率是钍铀燃料循环中的重要数据.为了测量基于聚变-裂变混合能源堆包层概念设计的钍样品在宏观中子学装置中的钍快中子裂变数据,发展了钍快中子裂变率的离线活化γ测量方法.通过测量232Th裂变碎片85mKr的β衰变产物85Rb发射的151.16 keV特征γ射线,并结合钍裂变产额数据,获得了钍样品装置中232Th裂变反应率的分布.详细介绍了此方法的原理和影响因素,并利用14 MeV的D-T中子源在贫铀球壳中开展了校验实验,实验不确定度为5.3%—5.5%.采用MCNP5程序和ENDF/B-VI及ENDF/B-VII数据库模拟计算的结果与实验结果在实验不确定度内基本符合,这证明该方法能够有效地模拟装置中232Th裂变反应率. 相似文献
5.
Measurements of the reaction rate distribution were carried out using two kinds of Plate Micro Fission Chamber (PMFC). The first is a depleted uranium chamber and the second an enriched uranium chamber. The material in the depleted uranium chamber is strictly the same as the material in the uranium assembly. With the equation solution to conduct the isotope contribution correction, the fission rate of 238U and 235U were obtained from the fission rate of depleted uranium and enriched uranium. Then, the fission count of 238U and 235U in an individual uranium shell was obtained. In this work, MCNP5 and continuous energy cross sections ENDF/BV.0 were used for the analysis of fission rate distribution and fission count. The calculated results were compared with the experimental ones. The calculation of fission rate of DU and EU were found to agree with the measured ones within 10% except at the positions in polyethylene region and the two positions near the outer surface. Because the fission chamber was not considered in the calculation of the fission counts of 238U and 235U, the calculated results did not agree well with the experimental ones. 相似文献
6.
W/Si多层膜反射镜在硬X射线天文望远镜中有重要应用. 为减小其应力对反射镜面形和望远镜分辨率的影响, 同时保证较高的反射率, 采用150, 175和200 ℃ 的低温退火工艺对采用磁控溅射镀制的W/Si周期多层膜进行后处理. 利用掠入射X射线反射测试和样品表面面形测试对退火前后W/Si多层膜的应力和结构进行表征. 结果表明, 在150 ℃ 退火3 h 后, 多层膜1级峰反射率和膜层结构几乎没有发生变化, 应力减少约27%; 在175 ℃ 退火3 h后, 多层膜膜层结构开始发生变化, 应力减少约50%; 在200 ℃退火3 h 后, 多层膜应力减小超过60%, 但1级布拉格峰反射率相对下降17%, 且膜层结构发生了较大变化. W, Si界面层的增大和相互扩散加剧是应力和反射率下降的主要原因. 相似文献
7.
用高真空磁控溅射设备分别在工作气压为0.40Pa和0.67Pa下制备了非晶碳膜全反射镜样品,利用X射线掠入射反射测量了膜层厚度、粗糙度和膜层密度,用原子力显微镜测量了样品的表面粗糙度,用同步辐射测量了不同工作气压下制备的非晶碳膜全反射镜的反射率,并对测量结果进行了分析讨论.测试结果表明:在0.40Pa工作气压下制备的非晶碳膜反射镜的性能优于在0.67Pa工作气压下制备的反射镜的性能,在掠入射角小于4.5°时,非晶碳膜全反射镜在5nm以上波段有比较平坦的高反射率,在波长小于5nm波段,反射率急剧下降. 相似文献
8.
研究了极紫外波段的双功能光学元件。采用周期膜叠加的思想,运用遗传方法优化设计了在19.5 nm处高反,在30.4 nm处抑制的双功能多层膜。采用磁控溅射技术制备了多层膜,利用X射线衍射仪测试了多层膜的结构,在国家同步辐射实验室测试了双功能多层膜的反射特性。结果表明:制备出的双功能膜性能与设计相符,在入射角13°,19.5 nm处的反射率达到33.3%,接近传统的19.5 nm周期高反膜的反射率,并且在30.4 nm附近将反射率由1.1%降到9.6×10-4。 相似文献
9.
为校验次临界能源堆的概念设计,在R19.4/30.0 cm的贫铀球壳装置上采用活化法开展14 MeV中子学积分实验.布放6片贫铀活化片于球壳中与入射D离子束90°方向上的不同位置处活化,用HPGe探测器测量238U(n,γ)反应、238U(n,f)及235U(n,f)反应和238U(n,2n)各反应产物发射的特征γ射线,得到了相应的反应率.238U(n,γ)反应率的不确定度为3.6%-3.7%,238U(n,D和235U(n,f)反应率的不确定度为5.1%-5.9%,238U(n,2n)反应率的不确定为4.3%-4.7%.用MCNP5程序在ENDF66c数据库下进行模拟计算,238U(n,γ)反应率的计算值/实验值(C/E)为0.972-1.034,238U(n,f)和235U(n,f)反应率的C/E为0.983-1.058,238U(n,2n)反应率的C/E为0.979-1.019. 相似文献
10.
基于CH柱形靶压缩实验的时间分幅诊断需求,研制了4.75 keV能点四通道Kirkpatrick-Baez(KB)显微镜。进行了四通道KB系统的光学设计、像质模拟和分析。采用支撑锥芯的方式解决了四通道KB物镜的集成装配问题,并通过4.75 keV+8 keV双能点多层膜完成了实验室内的KB系统装调。该套系统在神光Ⅱ装置成功进行了像质考核实验,获得了高分辨的四象限网格图像,成像间距符合设计要求,具备了开展时间分幅惯性约束聚变物理实验的条件。 相似文献