排序方式: 共有55条查询结果,搜索用时 31 毫秒
1.
2.
3.
4.
5.
6.
用弹性散射对多通道(e,2e)谱仪两维位置灵敏探测器的能量和动量响应函数进行了刻度,从位置灵敏探测器输出的两维位置信息中获得了弹性散射的能谱和角度谱,估计了在当前实验条件下的能量分辨和角度分辨.同时,我们用正交多项式的最小二乘法拟合得到了谱仪单路的能量和动量响应函数. 相似文献
7.
Theoretical calculation of triple differential cross sections of 3s orbital of argon in coplanar symmetric (e, 2e) reaction 总被引:1,自引:0,他引:1
The triple differential cross section for the low-energy electron impact ionization of inner-valence 3s orbital of argon has been calculated using the modified distorted wave Born approximation in coplanar symmetric energy-sharing geometry. Satisfactory agreement between theory and experiraent is achieved when the polarization and post-collisional interaction (PCI) are included in the calculations. It is shown that the polarization and PCI effects play a very important role in the case of argon at low incident energies. 相似文献
8.
Conservation Laws for the Derivative Nonlinear Schroedinger Equation with Non-vanishing Boundary Conditions
下载免费PDF全文

Conservation laws for the derivative nonlinear Schr6dinger equation with non-vanishing boundary conditions are derived, based on the recently developed inverse scattering transform using the affine parameter technique. 相似文献
9.
Electron Momentum Distributions of the Highest Occupied Molecular Orbital of CF3Br: Delocalization of Halogen Lone-Pair Orbitals
下载免费PDF全文

The highest occupied molecular orbital (HOMO) of trifluorobromomethane (CF3Br) is studied by binary (e,2e)electron momentum spectroscopy. The experimental momentum profile of the HOMO is compared with the Hartree-Fock (HF) and density functional theory (DFT-B3LYP) calculations. The calculated results largely depend on the size of basis sets rather than theoretical methods. Both the HF and DFT calculations using the 6-311 G^** basis set give a good explanation to the experiment. Delocalization of halogen lone-pair orbitals in the series molecules CF3X (X=F, Cl, Br) has been investigated. 相似文献
10.
The experimental relationship between width and amplitude of the non-destructive threshold pulse for Pt tip of a scanning tunneling microscope (STM) on graphite surface have been studied strictly and systematically in a wide range of pulse width for the first time. The threshold curve of amplitude versus width indicates that the amplitude of threshold pulse will increase with the decrease of the pulse width. A more rigorous explanation is suggested to interpret the dependence of threshold pulse amplitude on width. Fitted with the experimental data,a new empirical formula is given, extrapolated from which the threshold pulse amplitude will rise to 50 V when the pulse width decreases to 10ns. 相似文献