首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  免费   5篇
  国内免费   7篇
力学   7篇
物理学   5篇
  2018年   1篇
  2014年   2篇
  2007年   5篇
  2006年   1篇
  2005年   3篇
排序方式: 共有12条查询结果,搜索用时 46 毫秒
1.
The hazard of Hg ion pollution triggers the motivation to explore a fast, sensitive, and reliable detection method.Here, we design and fabricate novel 36-nm-thick Ag–Au composite layers alternately deposited on three-dimensional(3D)periodic SiO_2 nanogrids as surface-enhanced Raman scattering(SERS) probes. The SERS effects of the probes depend mainly on the positions and intensities of their localized surface plasmon resonance(LSPR) peaks, which is confirmed by the absorption spectra from finite-difference time-domain(FDTD) calculations. By optimizing the structure and material to maximize the intrinsic electric field enhancement based on the design method of 3D periodic SERS probes proposed,high performance of the Ag–Au/SiO_2 nanogrid probes is achieved with the stability further enhanced by annealing. The optimized probes show the outstanding stability with only 4.0% SERS intensity change during 10-day storage, the excellent detection uniformity of 5.78%(RSD), the detection limit of 5.0×10~(-12) M(1 ppt), and superior selectivity for Hg ions. The present study renders it possible to realize the rapid and reliable detection of trace heavy metal ions by developing highperformance 3D periodic structure SERS probes by designing novel 3D structure and optimizing plasmonic material.  相似文献   
2.
光学读出式红外成像技术是近年来研究的热点,本文讨论了镜面弯曲对光学检测灵敏度的影响。由双材料微悬臂梁组成的非致冷焦平面阵列通过体刻蚀工艺加工而成,由于残余应力的影响,制成的焦平面阵列将会发生弯曲,应力导致的镜面弯曲将会降低光学探测灵敏度。本文通过傅立叶光学模拟了镜面弯曲对光学探测灵敏度的影响,并通过实验验证了该模型。实验和模拟结果表明,在镜面曲率为0 .1mm-1时,光学探测灵敏度将会降低到理想情况的40 %。最后我们用这个模型评价了通过表面修饰来提高光学性能的效果。  相似文献   
3.
光学读出微梁阵列红外成像及性能分析   总被引:4,自引:0,他引:4       下载免费PDF全文
在构建的光学读出微梁阵列(焦平面阵列FPA)非制冷红外成像系统中,实现了无硅基底FPA置于空气中对人体的热成像. 通过FPA在不同真空度环境条件下的成像结果进行比较,分析了热导和系统噪声值随气压变化的关系,以及对系统成像性能的影响,并对气体分子热运动自由程大于空气传热层特征尺度时的气体热传导模型进行了修正分析和实验验证. 实验结果表明:FPA置于空气中时,气体分子撞击微梁引起的微梁反光板无序振动产生的光学读出噪声成为系统噪声的主要来源. 当真空度小于1Pa时,总热导和光学读出噪声值的变化都趋于平缓;当真空度小于10-2Pa时,空气热导的影响可忽略,总热导降低到微梁感热像素的辐射极限,光学读出噪声也降低到一极小值. 实验结果与理论分析相符合. 关键词: 非制冷红外成像 光学读出 双材料微梁阵列 热导  相似文献   
4.
光学读出式红外成像技术是近年来研究的热点,本文讨论了镜面弯曲对光学检测灵敏度的影响。由双材料微悬臂梁组成的非致冷焦平面阵列通过体刻蚀工艺加工而成,由于残余应力的影响,制成的焦平面阵列将会发生弯曲,应力导致的镜面弯曲将会降低光学探测灵敏度。本文通过傅立叶光学模拟了镜面弯曲对光学探测灵敏度的影响,并通过实验验证了该模型。实验和模拟结果表明,在镜面曲率为0.1mm-1时,光学探测灵敏度将会降低到理想情况的40%。最后我们用这个模型评价了通过表面修饰来提高光学性能的效果。  相似文献   
5.
Pixelated micropolarizer arrays (PMAs) have recently been used as key components to achieve real-time phase measurement. PMA fabrication by electron beam lithography and inductively coupled plasma-reactive ion etching is proposed in this work. A 320 × 240 aluminum PMA with 7.4 μm pitch is successfully fabricated by the proposed technique. The period of the grating is 140nm, and the polarization directions of each of the 2 × 2 units are 0°, 45°, 90°, and 135°. The scanning electron microscopy and optical microscopy results show that the PMA has a good surface characteristic and polarization performances. When the PMA is applied to phase-shifting interferometry, four fringe patterns of different polarization directions are obtained from only one single frame image, and then the object wave phase is calculated in real time.  相似文献   
6.
光学读出室温物体红外成像   总被引:8,自引:3,他引:5  
光学读出式红外成像系统是近年来提出的一种新型红外成像技术,它是基于探测双材料微悬臂梁吸收红外辐射后的变形。本文采用了谱平面刀口滤波方法,将双材料(SiNx/Au)微梁阵列接收热像后的转角变形转化为像平面上微梁阵列的像所对应的光强变化,并设计制作了无基底单层膜结构微梁阵列(100×100pixels,微梁尺寸200×200μm2,厚2μm)。用该阵列在光学读出系统中,获得了室温下人体的热图像。该系统在室温时(300K)噪声等效温度差(NETD)达到0.2K。  相似文献   
7.
本文给出了一种用于非制冷光学读出红外探测器的核心器件--微悬臂梁阵列的设计和制作,它是SiNx/Au双材料单层膜结构,简化制作工艺、可以直接在空气中成像.实验使用了设计制作的140 × 98微梁阵列和高信噪比的12-bit CCD,得到120℃以上的物体热像,噪声等效温度差(NETD)为5K左右,实验结果与热机械模型预测结果一致.  相似文献   
8.
光学读出式红外成像技术是近年来研究的热点,本文讨论了镜面弯曲对光学检测灵敏度的影响.由双材料微悬臂梁组成的非致冷焦平面阵列通过体刻蚀工艺加工而成,由于残余应力的影响,制成的焦平面阵列将会发生弯曲,应力导致的镜面弯曲将会降低光学探测灵敏度.本文通过傅立叶光学模拟了镜面弯曲对光学探测灵敏度的影响,并通过实验验证了该模型.实验和模拟结果表明,在镜面曲率为0.1mm-1时,光学探测灵敏度将会降低到理想情况的40%.最后我们用这个模型评价了通过表面修饰来提高光学性能的效果.  相似文献   
9.
光学读出非制冷红外成像的最新进展   总被引:3,自引:0,他引:3  
针对以前红外成像中红外图像的噪声等效温度差(NETD)较大和空间分辨率不高的问题,本文在制作工艺改善的基础上,设计了一个单元尺寸分别是50μm×50μm和60μm×60μm的红外焦平面阵列(FPA),它是由0.5μm厚的SiNX和0.2μm厚的Au构成的双材料微悬臂梁阵列构成。微梁单元倾斜角的变化利用在谱平面刀口滤波的光学方法测量。FPA是利用基于体硅的表面微加工工艺制作的,利用制作的FPA的60μm×60μm单元区域和12bit CCD,得到了室温物体的热像。讨论了60μm×60μm单元区域的性能,给出了NETD在100mK左右。和以前的工作相比,红外图像的温度分辨率和空间分辨率都得到了明显改善。  相似文献   
10.
像素偏振片阵列制备及其在偏振图像增强中的应用   总被引:2,自引:0,他引:2       下载免费PDF全文
张志刚  董凤良  张青川  褚卫国  仇康  程腾  高杰  伍小平 《物理学报》2014,63(18):184204-184204
像素偏振片阵列在实时测量光的斯托克斯参量方面具有重要的应用.本文设计和制作了基于金属铝纳米光栅的像素偏振片阵列,制作工艺基于电子束曝光技术.偏振片阵列单元尺寸为7.4μm,每相邻2×2单元的透偏振方向分别为0,7π/4,π/2和3π/4.光栅周期为140 nm,占空比为0.5,深度100 nm,光栅面型为矩形.像素偏振片阵列的扫描电子显微镜照片显示,制备的偏振片阵列的金属纳米光栅栅线无断线、无交叉、无杂物污染,光栅栅线结构平直,厚度均匀,满足理想矩形面型.采用偏振光作为照明光的光学显微镜拍摄图片显示,像素偏振片阵列整体形状规则,具有很好的偏振特性,最大偏振透射率可达到79.3%,消光比可达到454.将像素偏振片阵列与CCD(charge coupled device)集成在一起,采集单帧图像即可计算图像的斯托克斯参量,从而得到拍摄物体线偏振度图像和线偏振角图像,实现了偏振增强,可应用于目标反隐和识别.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏