首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   84篇
  免费   6篇
  国内免费   6篇
化学   65篇
力学   3篇
数学   8篇
物理学   20篇
  2023年   2篇
  2022年   3篇
  2021年   11篇
  2020年   2篇
  2019年   9篇
  2018年   8篇
  2017年   2篇
  2016年   9篇
  2015年   2篇
  2014年   7篇
  2013年   8篇
  2012年   8篇
  2011年   4篇
  2010年   7篇
  2009年   5篇
  2008年   1篇
  2007年   3篇
  2006年   4篇
  2005年   1篇
排序方式: 共有96条查询结果,搜索用时 578 毫秒
1.
Reusable [bmIm]OH was found to be a highly efficient renewable homogenous catalyst for the rapid and convenient synthesis of benzoxazine-4-one derivatives from o-iodobenzoic-acid and benzonitrile at 75 °C in moderate to good yields. This methodology provides a facile and straightforward path to construct other related heterocycles in an eco-compatible fashion.  相似文献   
2.
3.
A flow-injection chemiluminescence method has been established for the determination of total iron in freshwater samples. The enhanced chemiluminescence emission was caused by the iron(II) from the neutralisation reaction of hydrochloric acid and sodium hydroxide without the use of any chemiluminescent reagent. The calibration graph was linear in the concentration range of 2.8–560 µg L?1 (r 2 = 0.9983, n = 8), with relative standard deviation (RSD; n = 4) in the range of 0.8–2.6%. The limit of detection (S/N = 3) was 0.56 µg L?1 with injection throughput of 180 h?1. The effect of common anions and cations were studied over their environmentally relevant concentrations in freshwaters. The method was successfully applied to determine total iron in freshwater samples. Iron(III) was reduced to iron(II) by using hydroxylammonium chloride. The proposed method was compared with spectrophotometric method and there was no significant difference between the two methods at the 95% confidence level (t-test). Analysis of river water (certified reference material SLRS-4) for iron(II), after reduction of iron(III) with hydroxylammonium chloride, gave good results (2.17 ± 0.22 µM compared with the certificate value of 1.85 ± 0.1 µM).  相似文献   
4.
Lucigenin chemiluminescence (CL) in conjunction with flow-injection analysis (FIA) is used for the determination of phosphate in freshwater samples. The procedure is based on the formation of molybdophosphoric heteropoly acid (MoP–HPA) by the reaction of phosphate and ammonium molybdate under acidic conditions. CL emission was observed as a result of oxidation of lucigenin in aqueous sodium hydroxide solution in the presence of MoP–HPA. Calibration was linear up to 500?µg?L?1 (r 2?=?0.9998; n?=?8), with a detection limit (S/N?=?3) of 0.95?µg?L?1. An injection throughput of 120 h?1, and relative standard deviation (RSD; n?=?4) of 1.3–3.2% were achieved in the concentration range studied. An on-line chelating column was used to remove interfering cations. The method was applied to freshwater samples, and the results (51?±?1.0 – 107?±?2.0?µg?L?1) did not differ significantly from results obtained using a spectrophotometric method (52.5?±?1.0 – 102?±?2.0?µg?L?1) at 95% confidence level (t-test).  相似文献   
5.
ABSTRACT

Contamination of groundwater by heavy metal is one of the most emerging and serious environmental problems. There are so many methods which are available to overcome these problems. Among various available methods, hybrid organic–inorganic ion exchange resin has become more popular due to certain advantages over other available conventional methods; hence, in the present proposed work, we synthesised a hybrid organic–inorganic composite material polyacrylamide zirconium (IV) iodosulphosalicylate by using the sol-gel technique. Synthesised resin was characterised by various methods like Infrared spectroscopy and Thermogravimetric analysis-Differential thermal analysis. Various samples of this ion exchange resin are prepared by changing the condition of synthesis, i.e. concentration of acrylamide to rationalise the ion exchange capacity of the synthesise hybrid organic–inorganic ion exchange resins. A mixture of 0.1 M potassium iodate, 0.1 M sulphosalicylic acid and 0.1 M acrylamide was added dropwise to 0.4 M zirconium oxychloride accompanied by constant stirring for 8 h using magnetic stirrer at 70°C to yield polyacrylamide zirconium (IV) iodosulphosalicylate with maximum ion exchange capacity. Ion exchange capacity of synthesised resin was determined by column method and the maximum ion exchange capacity was found for Pb(II). Determination of kd values shows that the resin was highly selective for Pb (II).The selectivity for Pb was also evaluated by using certain binary mixture separation such as Ni (II)-Pb(II), Cu(II)-Pb(II), Cd(II)-Pb(II), Sr(II)-Pb(II), Ba(II)-Pb(II),Zn(II)-Pb(II) and Mg(II)-Pb(II).  相似文献   
6.
A flow-injection procedure is described for the determination of carbaryl based on its inhibition effect on luminol-cobalt(II) chemiluminescence reaction in alkaline medium in the presence of hydrogen peroxide. The calibration data over the range 5.0?×?10?7 to 20?×?10?6?M give a correlation coefficient (r 2) of 0.9972 with relative standard deviations (RSD; n?=?4) in the range of 1.0–2.1% with a limit of detection (3?×?blank noise) of 2.37?×?10?7?M for carbaryl. The sample throughput was 120?h?1. The effects of some carbamates, anions, and cations were studied on luminol CL system for carbaryl determination. The proposed method has been applied to determine carbaryl in natural waters.  相似文献   
7.
Journal of Thermal Analysis and Calorimetry - The thermal performance of an isothermal horizontal cylinder with different selected cross sections in cross-flow was investigated numerically. These...  相似文献   
8.
Methods for the bulk ablation of soft tissue using intense ultrasound, with potential applications in the thermal treatment of focal tumors, are presented. An approximate analytic model for bulk ablation predicts the progress of ablation based on tissue properties, spatially averaged ultrasonic heat deposition, and perfusion. The approximate model allows the prediction of threshold acoustic powers required for ablation in vivo as well as the comparison of cases with different starting temperatures and perfusion characteristics, such as typical in vivo and ex vivo experiments. In a full three-dimensional numerical model, heat deposition from array transducers is computed using the Fresnel approximation and heat transfer in tissue is computed by finite differences, accounting for heating changes caused by boiling and thermal dose-dependent absorption. Similar ablation trends due to perfusion effects are predicted by both the simple analytic model and the full numerical model. Comparisons with experimental results show the efficacy of both models in predicting tissue ablation effects. Phenomena illustrated by the simulations and experiments include power thresholds for in vivo ablation, differences between in vivo and ex vivo lesioning for comparable source conditions, the effect of tissue boiling and absorption changes on ablation depth, and the performance of a continuous rotational scanning method suitable for interstitial bulk ablation of soft tissue.  相似文献   
9.
Sadia  Waseem  Pauzi  Abdullah 《Chromatographia》2009,69(11):1447-1451

The development and optimization of analytical methods for the better monitoring of disinfection by-products especially haloacetic acids in water are key step in order to estimate human exposure to such products after chlorination. A reliable and accurate analytical method is needed in order to reach the levels of concentration required by United States Environmental Protection Agency regulations. In this study a method was developed for determining halogenated acetic acids in drinking water, involving solid phase extraction, methylation derivatization, and GC-MS. The new SPE-GC-MS-SIM method is capable of analyzing all nine acids at extremely low μg L–1 level. Run time is significantly reduced without compromising analytical results. The major advantages of the method are the simplicity of the chromatography, short run time and low detection limits. The method performance, limits of detection and spiking recovery were evaluated and the results proved that the accuracy and precision were good. This method outperforms previous GC-MS methods especially for the determination of dibromoacetic, dibromochloroacetic, dichlorobromoacetic and tribromoacetic acids. The method has been used to analyse domestic tap water and water samples collected at a local water treatment plant.

  相似文献   
10.
International Journal of Theoretical Physics - Most of the enciphering structures are based on the transformation of mediums by describing the strict criteria. The presented article is based on...  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号