首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   54篇
  免费   2篇
  国内免费   1篇
化学   42篇
数学   1篇
物理学   14篇
  2021年   3篇
  2020年   5篇
  2019年   1篇
  2016年   2篇
  2015年   2篇
  2014年   1篇
  2011年   2篇
  2010年   2篇
  2008年   2篇
  2006年   1篇
  2005年   2篇
  2004年   1篇
  2002年   6篇
  2001年   13篇
  1998年   1篇
  1997年   1篇
  1996年   1篇
  1990年   1篇
  1989年   2篇
  1988年   1篇
  1985年   2篇
  1881年   1篇
  1879年   2篇
  1878年   2篇
排序方式: 共有57条查询结果,搜索用时 15 毫秒
1.
A simple, accurate and reproducible reversed-phase high-performance liquid chromatography (HPLC) method was developed for the separation and characterisation of alkylphenols (APs) and alkylphenol polyethoxylates (APEOs), using a C18 octadecyl silica (ODS) column. APs and each APEO oligomer were separated successfully within a reasonable time without gradient elution. An excellent resolution was obtained, even for mixtures of APs and low EO number APEOs, which are otherwise difficult to separate using conventional normal-phase HPLC methods. This method, combined with solid-phase extraction, was highly applicable for the simultaneous determination of alkylphenols and alkylphenol ethoxylates in real samples.  相似文献   
2.
Pristine and WO3 decorated TiO2 nanorods (NRs) were synthesised to investigate n-n-type heterojunction gas sensing properties. TiO2 NRs were fabricated via hydrothermal method on fluorine-doped tin oxide coated glass (FTO) substrates. Then, tungsten was sputtered on the TiO2 NRs and thermally oxidised to obtain WO3 nanoparticles. The heterostructure was characterised by X-ray diffraction (XRD), scanning electron microscopy (SEM), and energy-dispersive X-ray (EDX) spectroscopy. Fabricated sensor devices were exposed to VOCs such as toluene, xylene, acetone and ethanol, and humidity at different operation temperatures. Experimental results demonstrated that the heterostructure has better sensor response toward ethanol at 200 °C. Enhanced sensing properties are attributed to the heterojunction formation by decorating TiO2 NRs with WO3.  相似文献   
3.
Early detection of pathogenic microorganisms is pivotal to diagnosis and prevention of health and safety crises. Standard methods for pathogen detection often rely on lengthy culturing procedures, confirmed by biochemical assays, leading to >24 h for a diagnosis. The main challenge for pathogen detection is their low concentration within complex matrices. Detection of blood-borne pathogens via techniques such as PCR requires an initial positive blood culture and removal of inhibitory blood components, reducing its potential as a diagnostic tool. Among different label-free microfluidic techniques, inertial focusing on microscale channels holds great promise for automation, parallelization, and passive continuous separation of particles and cells. This work presents inertial microfluidic manipulation of small particles and cells (1–10 μm) in curved serpentine glass channels etched at different depths (deep and shallow designs) that can be exploited for (1) bacteria preconcentration from biological samples and (2) bacteria-blood cell separation. In our shallow device, the ability to focus Escherichia coli into the channel side streams with high recovery (89% at 2.2× preconcentration factor) could be applied for bacteria preconcentration in urine for diagnosis of urinary tract infections. Relying on differential equilibrium positions of red blood cells and E. coli inside the deep device, 97% red blood cells were depleted from 1:50 diluted blood with 54% E. coli recovered at a throughput of 0.7 mL/min. Parallelization of such devices could process relevant volumes of 7 mL whole blood in 10 min, allowing faster sample preparation for downstream molecular diagnostics of bacteria present in bloodstream.  相似文献   
4.
In this study, the catalytic activity and stability of flowerlike hybrid horseradish peroxidase (HRP) nanobiocatalyst (HRP-Cu 2+ ) obtained from Cu 2+ ions and HRP enzyme in the polymerization reaction of guaiacol were analyzed. We demonstrated that HRP-Cu 2+ and hydrogen peroxide (H 2 O 2 ) initiator showed significantly increased catalytic activity and stability on the polymerization of guaiacol compared to that of free HRP enzyme. Poly(guaiacol) was observed with quite high yields (88%) and molecular weights (38,000 g/mol) under pH 7.4 phosphate-buffered saline (PBS) conditions at 60 °C with 5 weight% of HRP-Cu 2+ loading. HRP-Cu 2+ also shows very high thermal stability and works even at 70 °C reaction temperature; free HRP enzyme denatures at that temperature. Furthermore, HRP-Cu 2+ provided considerable repeated use and showed some degree of catalytic activity, even after the fourth recycle, in the polymerization of guaiacol.  相似文献   
5.
The volatile components of essential oil (EO), SPME, and SPME of solvent extracts ( n -hexane, methanol, and water) obtained from fresh Serapias orientalis subsp. orientalis ( Soo ) were analyzed by GC-FID/MS. EO of Soo gave 11 compounds in the percentage of 99.97%; capronaldehyde (37.01%), 2-( E )-hexenal (23.19%), and n -nonanal (19.05%) were found to be major constituents. SPME GC-FID/MS analyses of fresh plant and solvent extracts of Soo revealed 7, 12, 7, and 4 compounds within the range of 99.7% to 99.9%. Limonene (76.5%, 41.7%, and 61.3%) was the major compound in SPMEs of the n -hexane and methanol extracts. α -Methoxy- p -cresol (52.9%) was the main component in its water extract. The antimicrobial activity of EO and the solvent extracts of Soo were screened against 9microorganisms. EO showed the best activity against Mycobacterium smegmatis , with 79.5 µg/mL MIC value. The n -hexane, methanol, and water extracts were the most active against the Staphylococcus aureus within the range of 81.25–125.0 µg/mL (MIC). IC 50 values for the lipase enzyme inhibitory activity of EO and solvent extracts ( n -hexane, methanol, and water) were determined to be 59.87 µg/mL, 64.03 µg/mL, 101.91 µg/mL, and 121.24 µg/mL, respectively.  相似文献   
6.

Background

Pentachloronitrobenzene (PCNB) and hexachlorobenzene (HCB) are highly toxic and widespread in every environmental compartment. Some of metabolic products such as amino/nitro containing chlorinated aromatic compounds can be determined by gas chromatography coupled with electron capture detector (GC-ECD). However, it is difficult to identify some of chlorophenolic and chloroquinolic intermediates produced from PCNB and HCB by the above mentioned technique. Therefore, for analysis of these compounds and their metabolites, we have developed a high performance liquid chromatography (HPLC) based method.

Results

The extraction of PCNB and HCB from soil and minimal salt medium was carried out with ethyl acetate and hexane respectively with good recoveries (98% for PCNB and 97% for HCB). The validation of the proposed extraction and HPLC method was done by analysis of PCNB and HCB biodegradation and their metabolites identification from anaerobic enriched soil samples.

Conclusion

A rapid, sensitive and simple HPLC based analytical method was developed for the analysis of PCNB, HCB and their possible intermediates.  相似文献   
7.
We consider the thermoelastic plate under the presence of along range memory. We find uniform rates of decay (in time)of the energy, provided that suitable assumptions on the relaxationfunctions are given. Namely, if the relaxation decays exponentiallythen the first order energy also decays exponentially. Whenthe relaxation g satisfies -c1g(t)1+1/p g'(t) -cog(t)1+1/p; and g,g1-1/p L1 (R) withp > 2 then the energy decays as 1/(1+t)p. A new Liapunov functionalis built for this problem.  相似文献   
8.
Using integer and noninteger n-Slater type orbitals in single- and double-zeta approximations, the Hartree-Fock-Roothaan calculations were performed for the ground states of first ten cationic members of the isoelectronic series of He atom. All the noninteger parameters and orbital exponents were fully optimized. In the case of noninteger n-Slater type orbitals in double zeta basis sets, the results of calculations obtained are more close to the numerical Hatree-Fock values and the average deviations of our ground state energies do not exceed 2×10-6 hartrees of their numerical results.  相似文献   
9.
An ion chromatographic (IC) method has been developed for determination of hydrogen ion (H+). It is based on the use of sulfonated cation-exchange resin as stationary phase, aqueous ethylenediamine-N,N,N′,N′-tetraacetic acid (dipotassium salt, EDTA-2K, written as K2H2Y) solution as mobile phase, and conductivity for detection. H+ was separated mainly by cation-exchange, but its elution was accelerated by the presence of EDTA. The order of elution for the model cations was H+ > Li+ > Na+ > NH4 + > Ca2+ > > Mg2+. A sharp and highly symmetrical peak was obtained for H+ and this was attributed to the capacity of H2Y2 2– to receive and bind H+. H+ was detected conductiometrically and detector response (reduction in conductivity as a result of H++H2Y2–→H3Y) was linearly proportional to the concentration of H+ in the sample. The detection limit for H+ with this IC system was better than 4.7 μmol L–1. A significant advantage of this method was the ability to separate and determine, in one step, H+ and other cations. The successful determination of H+ and other cation species in real acid-rain samples demonstrated the usefulness of this method.  相似文献   
10.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号