1.
 An analytical result is not considered to be complete without a statement of the measurement uncertainty associated with it. Evaluation of measurement uncertainty is therefore an essential part of every determination. In the present study the measurement uncertainty of the result of determination of selenium in the reference material Seronorm Trace Elements Serum was studied. The combination of a digestion procedure using sulfuric acid, V2O5 in H2SO4 and hydrogen peroxide and the continuous flow approach of hydride generation atomic fluorescence spectrometry (HG-AFS) detection was used for selenium determination. The total uncertainty budget was calculated with the help of the GUM Workbench program, in which computations follow the rules of the ’ISO guide to the expression of uncertainty in measurement’. The major sources of uncertainty were found to be due to the recovery of the procedure, measurement of peak heights and the purity of Na2SeO3. A selenium mass fraction of 77.1±4.8 ng/g (with a coverage factor of 2.1, 95% probability) was determined, which is comparable with the recommended value of 80 ng/g. Received: 13 September 2002 Accepted: 23 December 2002 Acknowledgements We would like to thank Tinkara Buˇcar, B.Sc. for useful discussions and the IAEA Vienna, for financial support of the project 11553/RO. Presented at CERMM-3, Central European Reference Materials and Measurements Conference: The function of reference materials in the measurement process, May 30–June 1, 2002, Rogaška Slatina, Slovenia Correspondence to V. Stibilj  相似文献   
2.
Development of a method for very low level selenium determination in water soluble protein and peptide fractions, obtained after various separation procedures, is presented. A hydride generation atomic fluorescence spectrometry (HG-AFS) detection system was optimised and the influence of Cu(II), Sb(V), As(III) and HNO3 interferences in the measurement of Se by HG-AFS was investigated. A destruction procedure using HNO3 and H2O2 was also optimised and the average recovery of the digestion of a solution of selenomethioneine was 92 ± 4% (n=14). Combination of this digestion with the detection system gave reliable results. Accuracy was tested by comparison with two independent methods. A very low detection limit (DL) of 0.2 ng/g of measuring solution was achieved. The whole procedure from weighing to measuring was performed in the same Teflon tube. The addition of HNO3 to the fractions before long term storage at -20°C was necessary to prevent adsorption on the test tubes.Selenium was measured in water soluble protein and peptide fractions obtained after extraction, and Sephadex G-75 chromatography performed on liver samples from: i) hens exposed to As2O3, ii) hens fed with a high fat feed and iii) the certified reference material dogfish liver (CRM DOLT-2). Because of the very low DL we were able to observe the Se distribution in chromatographic fractions of samples of organisms which were not exposed to excess amounts of Se. The presence of selenium associated with metallothioneins was observed.  相似文献   
3.
The method of hydride generation atomic fluorescence spectrometry (HG-AFS) was optimised for determination of selenium in food supplements. Due to the high and varied content of Cu, Mg and Zn in the samples, the standard addition method was found to be the most appropriate. The reliability of the method was checked by the independent method of radiochemical neutron activation analysis, and good agreement was found between the two methods. HG-AFS is simple and rapid for Se determination in food supplements based on minerals. Agreement between the selenium values found and declared was worse than 10% in 9 out of 13 supplements. Furthermore, 2 of the 14 supplements did not comply with the recommendations stated in the 27th edition of the U.S. Pharmacopoeia, which states that minerals and vitamins in food supplements should be in the range of 90 and 200% of the declared value.  相似文献   
4.
The purpose of the study was to optimise analytical methods for determination of the chemical speciation of mercury in studies of protective mechanisms of selenium. Optimisation of the methods was performed using CRM DOLT-2 (Dogfish liver), both in its original form and after separation of various fractions. The sample was homogenised with 10 mM Tris-HCl buffer (pH 7.6) and ultracentrifuged. The soluble phase obtained was applied to a size exclusion chromatography column (Sephadex G-75 column) for separation of various protein fractions. Total mercury (total Hg), monomethyl mercury (MeHg) and selenium (Se) were determined in whole dogfish liver tissue and its soluble and insoluble phases (pellet). Different approaches for determination of total Hg and MeHg were compared. Simultaneous determination of MeHg and inorganic mercury (Hg2+) was based on alkaline dissolution and/or acid leaching, followed by ethylation, room temperature precollection, isothermal gas chromatography (GC), pyrolysis and detection with cold vapour atomic fluorescence spectrometry (CVAFS). The sum of MeHg and Hg2+ was compared to total Hg results obtained by acid digestion and CVAAS detection. The accuracy of MeHg determination was checked by its determination using acid leaching at room temperature, solvent extraction, back extraction into Milli-Q water, ethylation, GC and CVAFS detection. For the insoluble phase it is recommended to use solvent extraction for MeHg and acid digestion CVAAS for total Hg. For determination of MeHg and Hg2+ in the lyophilised sample and water soluble fractions containing low concentrations of mercury species, the simultaneous measurement of MeHg and Hg2+ after alkaline dissolution is the most appropriate method.  相似文献   
5.
Iodine is one of the most important essential elements as demonstrated by the fact that its deficiency can cause goitre. Nevertheless, quantitative data on its concentration in biological materials, especially in the human brain, are scarce. There is therefore a demand for accurate and reliable information on iodine in these types of samples. The purpose of the present work was to determine the concentration of total iodine in some control human brain parts by rapid radiochemical neutron activation analysis. Our second goal was to determine I distribution between lipid fraction and in brain tissue without lipid by applying two types of solvent extraction methods. The results were checked by the analysis of biological standard reference materials with certified or literature values for iodine and good agreement was found.  相似文献   
6.
Major and trace element contents in iron ore reference materials were investigated using k 0-instrumental neutron activation analysis (k 0-INAA). To avoid iron interferences, radiochemical separation was developed (k 0-RNAA). The determination of the investigated elements in the inorganic phase from hydrochloric acid solution was performed after radiochemical separation of iron by diisopropyl ether. It was found that after the Fe elimination, the limit of detection for some elements was much lower that enables their direct determination. The distribution of 39 elements (with intermediate/medium and long half-life radionuclides) after Fe removal was investigated.  相似文献   
7.
The aim of this work was to check whether commercially available enzymes are pure enough to be used for selenium speciation analysis and the contribution that impurities could make to Se determination in real samples. For this purpose, twelve commercially available enzymes with different origins and classifications (protease, amylase, cellulase, lipase) were analysed. After the dissolution of the enzyme in water, the Se species were separated by ion exchange chromatography, with inductively coupled plasma mass spectrometry used as the detection system. The results showed that the Se content was significant in several cases. The highest value was obtained for β-amylase from barley, 3100 ng Se per g of enzyme. Speciation analysis showed that Se-methionine, selenite, selenate and some unknown compounds were present in several enzymes. In general, the Se species identified represented a small fraction of the total Se. For instance, only 17% of the total Se was determined for β-amylase from barley. On the other hand, about 100% of the total Se was identified in protease from Streptomyces griseus. Upon comparing the results from different lots of the same enzyme, not all of them were found to be comparable. Thus, the presence of selenium species in commercially available enzymes could be due to the preparation procedure used for the enzyme; they could be present as degradation products. Therefore, when determining selenium species in samples with low Se contents, attention should be paid to enzyme purity in relation to selenium compounds when an enzyme is used for hydrolysis.  相似文献   
8.
The neutron distribution in a defined volume (gradient) for different matrices (air, water, cellulose, biological material and silicon dioxide) in two typical irradiation channels (pneumatic tube (PT) and IC40-channel in the carousel facility) in the TRIGA Mark II reactor at the Joef Stefan Institute (IJS) was studied. Our experiment was based on inserting Fe wires (flux monitors) into the chosen matrices. The wires were cut into small pieces after irradiation and the induced activities of 59Fe measured. The results showed that for the studied geometry the average spatial thermal neutron flux inhomogeneities (for five studied matrices) are about 2.3% in the PT-channel and about 2.9% in the IC40-channel.  相似文献   
9.
The measurement uncertainty of iodine determination in NIST standard reference material (SRM) 1549 using radiochemical neutron activation analysis (RNAA) was studied. This method is based on ignition of the irradiated sample [127I(n,)128I, t1/2=25 min, E=422.9 keV] in an oxygen atmosphere, followed by absorption of iodine in a reducing acid solution and its purification by a selective extraction–stripping–reextraction cycle. The purified solution of iodine in CHCl3 was transferred to a well-type HPGe detector for -ray measurement of the induced radionuclide 128I. The detection limit of the method employed under the conditions described was 1 ng/g. The reproducibility of iodine determination in the SRM was 3.6% (12 determinations within 1 month), calculated by the analysis of variance procedure. Using the commercially available software program GUM Workbench and the recommendations of the Eurachem/CITAC Guide, we evaluated the uncertainty budget for this RNAA method and the relative uncertainty obtained was 3.6%. The largest uncertainty contributions were due to the repeatability of the chemical yield determination, the count rate of the induced nuclide in the standard and sample, the mass of the carrier and the mass of the irradiation standard.  相似文献   
10.
Two methods for chemical yield measurement of Se in biological samples after radiochemical neutron activation analysis when using the75Se nuclide are described, namely a Spectrophotometric technique and a radiotracer technique employing81mSe. These two approaches were compared and evaluated by applying them to the analysis of Se in various certified reference materials.  相似文献   