首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   21篇
  免费   0篇
物理学   21篇
  2011年   2篇
  2010年   3篇
  2008年   1篇
  2002年   1篇
  2000年   3篇
  1999年   2篇
  1996年   3篇
  1995年   2篇
  1994年   2篇
  1993年   1篇
  1990年   1篇
排序方式: 共有21条查询结果,搜索用时 281 毫秒
1.
2.
Measurements of synchrotron radiation emitted by 30-MeV runaway electrons in the TEXTOR-94 tokamak show that the runaway population decays after switching on neutral beam injection (NBI). The decay starts only with a significant delay, which decreases with increasing NBI heating power. This delay provides direct evidence of the energy dependence of runaway confinement, which is expected if magnetic modes govern the loss of runaways. Application of the theory by Mynick and Strachan [Phys. Fluids 24, 695 (1981)] yields estimates for the "mode width" (delta) of magnetic perturbations: delta<0.5 cm in Ohmic discharges, increasing to delta = 4.4 cm for 0. 6 MW NBI.  相似文献   
3.
The purpose of this study is to develop a fast and accurate temperature mapping method capable of both fat suppression and reduced field-of-view (rFOV) imaging, using a two-dimensional spatially-selective RF (2DRF) pulse. Temperature measurement errors caused by fat signals were assessed, through simulations. An 11×1140μs echo-planar 2DRF pulse was developed and incorporated into a gradient-echo sequence. Temperature measurements were obtained during focused ultrasound (FUS) heating of a fat-water phantom. Experiments both with and without the use of a 2DRF pulse were performed at 3T, and the accuracy of the resulting temperature measurements were compared over a range of TE values. Significant inconsistencies in terms of measured temperature values were observed when using a regular slice-selective RF excitation pulse. In contrast, the proposed 2DRF excitation pulse suppressed fat signals by more than 90%, allowing good temperature consistency regardless of TE settings. Temporal resolution was also improved, from 12 frames per minute (fpm) with the regular pulse to 28 frames per minute with the rFOV excitation. This technique appears promising toward the MR monitoring of temperature in moving adipose organs, during thermal therapies.  相似文献   
4.
Advances in neuroscience have resulted in the development of new diagnostic and therapeutic agents for potential use in the central nervous system (CNS). However, the ability to deliver the majority of these agents to the brain is limited by the blood-brain barrier (BBB), a specialized structure of the blood vessel wall that hampers transport and diffusion from the blood to the brain. Many CNS disorders could be treated with drugs, enzymes, genes, or large-molecule biotechnological products such as recombinant proteins, if they could cross the BBB. This article reviews the problems of the BBB presence in treating the vast majority of CNS diseases and the efforts to circumvent the BBB through the design of new drugs and the development of more sophisticated delivery methods. Recent advances in the development of noninvasive, targeted drug delivery by MRI-guided ultrasound-induced BBB disruption are also summarized.  相似文献   
5.
6.

Purpose

The purpose was to develop a new magnetic resonance imaging technique for fast temperature monitoring with extended volume coverage.

Materials and Methods

The Multiple Resolutions Along Phase-Encode and Slice-Select Dimensions (MURPS) method was implemented in both a two-dimensional (2D) spoiled gradient echo (SPGR) sequence and a multishot echo-planar imaging (EPI) sequence. Both modified sequences were used to acquire image data from three slices with variable phase-encode resolution and slice thickness. In the SPGR sequence, a 2D resonant frequency pulse was also implemented to enable imaging within a reduced field of view, and this was used to monitor (at 1.5 T) the temperature changes in a live rabbit and in gel phantoms heated by focused ultrasound. A modified EPI sequence was tested during heating of a phantom undergoing motion.

Results

The in vivo experiments demonstrated that temperature changes in unexpected locations away from the focal plane, such as near bone structures, could be detected due to the extra volume coverage afforded by the MURPS method. Temperature changes in a moving phantom were resolved using the MURPS EPI sequence with an acquisition rate of three slices every 300 ms.

Conclusion

The MURPS method enables temperature monitoring over multiple slices without loss of temporal resolution compared with single-slice imaging and, if combined with multishot EPI, enables volume temperature monitoring in moving organs.  相似文献   
7.
Bose-Einstein condensation in a gas of sodium atoms   总被引:2,自引:0,他引:2  
  相似文献   
8.
9.
A new approach to on-line oxygen isotope analysis has been developed which utilises existing elemental analyser and mass spectrometry technology to produce a sample of carbon dioxide gas for oxygen isotople analysis. The method relies on on-line high temperature pyrolysis of the sample over a carbon source followed by a rapid, non-contributive partial catalytic oxidation over nickel powder at between 550 and 600 degrees C. Initial results demonstrate both good precision (better than 0.2 per thousand) and accuracy for both cellulose and silver nitrate samples. Copyright 1999 John Wiley & Sons, Ltd.  相似文献   
10.
<正>Fiber optics underpins the communications infrastructure for the information society today. Cables consisting of hair-like fibers speed data around the globe in the form of rapid pulses of light. Modern telecom  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号