首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   3篇
  免费   0篇
化学   2篇
物理学   1篇
  2002年   1篇
  2001年   1篇
  1999年   1篇
排序方式: 共有3条查询结果,搜索用时 112 毫秒
1
1.
There is an increasing need for methods for efficient enantioselective separation and purification of chiral drugs. Genetic engineering provides the means for generating recombinant antibodies exhibiting extremely high specificity for even small molecular mass compounds. Here, recombinant antibody fragments have been generated for the drug diarylalkyltriazole that contains two chiral centres. Immobilised antibody fragments has been used successfully for efficient, step-wise separation of two enantiomers of the drug. Owing to the antibody specificity, one enantiomer came out in the flow-through, while the bound enantiomer could be specifically eluted. One of the antibodies tolerated solvents required both for dissolving the target molecules and for their elution for extended times and was shown to function over multiple cycles of the separation process.  相似文献   
2.
Journal of Nanoparticle Research -  相似文献   
3.
A colorimetric protein phosphatase inhibition assay (PPI assay), a commercial enzyme-linked immunosorbent assay (ELISA) test and different HPLC methods using UV detection were compared for the detection of cyanobacterial hepatotoxins, microcystins (MCYST) and nodularin. The suitability of the methods to detect different toxin variants was evaluated by using pure toxins and laboratory cultures as well as water and bloom samples of toxic cyanobacteria. The emphasis of the study was on the analysis of polar demethyl microcystin variants that are common in nature but for which there exist no commercial standards. The IC50 values of MCYST-LR for the PPI assay and the ELISA test were 2.2-2.5 and 0.26-0.38 μg l−1, respectively. The most important factors that decreased toxin recovery in sample treatment were the use of C18 cartridges and polypropylene containers. Good recoveries of toxins were obtained by using hydrophilic-lipophilic balanced (Oasis HLB, Waters) cartridges for concentrating the samples. The results obtained with the PPI assay, the ELISA test and HPLC correlated quantitatively well with the exception of [d-Asp3] microcystins. Concentrations of [d-Asp3]MCYST-RR measured with the PPI assay were only 5% of those obtained by the ELISA test and HPLC. Concentrations of hydrophobic microcystin variants were lower when analysed with ELISA than with the other methods. The World Health Organisation (WHO) has set a guideline value of 1 μg l−1 for the world-wide most common microcystin variant, MCYST-LR in drinking water. Since the quantitative ranges of the PPI assay and the ELISA test are within microcystin concentrations in natural waters, and both tests are easy to perform, they show potential for routine use in the screening and monitoring of microcystins from drinking water supplies and from recreational waters.  相似文献   
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号