首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   14篇
  免费   1篇
化学   2篇
数学   2篇
物理学   11篇
  2016年   1篇
  2015年   1篇
  2012年   1篇
  2008年   2篇
  2006年   2篇
  2004年   1篇
  2001年   1篇
  2000年   1篇
  1997年   1篇
  1996年   1篇
  1995年   1篇
  1984年   1篇
  1982年   1篇
排序方式: 共有15条查询结果,搜索用时 406 毫秒
1.
2.
Collocation type methods are studied for the numerical solutionof the weakly singular Volterra integral equation of the secondkind: where the solution (t) is assumedto have the form f(t) = x(t)+r?(t), x and being sufficientlysmooth. The solution is approximated near zero by a linear combinationof powers of t?, and away from zero by the usual polynomialrepresentation. Convergence is proved and many numerical experimentsare carried out with examples from the literature. A comparisonis made with a method of Brunner & Norsett (1981), originallydeveloped for (1) with a smooth solution. Special attentionis paid to the numerical approximation of the so-called momentintegrals which emerge in the collocation scheme.  相似文献   
3.
Results are presented of a recent experiment at the Imaging and Medical beamline of the Australian Synchrotron intended to contribute to the implementation of low‐dose high‐sensitivity three‐dimensional mammographic phase‐contrast imaging, initially at synchrotrons and subsequently in hospitals and medical imaging clinics. The effect of such imaging parameters as X‐ray energy, source size, detector resolution, sample‐to‐detector distance, scanning and data processing strategies in the case of propagation‐based phase‐contrast computed tomography (CT) have been tested, quantified, evaluated and optimized using a plastic phantom simulating relevant breast‐tissue characteristics. Analysis of the data collected using a Hamamatsu CMOS Flat Panel Sensor, with a pixel size of 100 µm, revealed the presence of propagation‐based phase contrast and demonstrated significant improvement of the quality of phase‐contrast CT imaging compared with conventional (absorption‐based) CT, at medically acceptable radiation doses.  相似文献   
4.
利用XRD、Raman、XPS和FT-IR表征技术,研究无机酸洗脱(HCl、H2SO4、HCl-HF)处理的胜利褐煤微晶结构的变化,采用自行设计的表面吸附仪-GC联用装置,对样品进行不同温度的低温脉冲氧化实验,考察了煤样在不同温度下氧吸附量的变化规律,通过低温脉冲氧吸附规律与TG/DTG和固定床燃烧实验关联,考察了煤样的自燃倾向。结果表明,无机酸洗脱对矿物质的脱除使得煤结构的有序度增加,石墨化程度提高,无机酸洗脱煤样与原煤相比吸氧量明显下降。随着吸附温度的升高,各煤样吸氧量明显增加,且随着脱除矿物质程度的增加,吸氧量呈减小的趋势,导致自燃倾向降低。  相似文献   
5.
6.
7.
The development of a scheme to treat two-dimensional electromagneticscattering by electrically large, perfectly conducting bodiesis described. It incorporates the effects of surface curvatureand non-local phenomena and has the potential to provide thebasis for a general technique yielding more accurate predictionsthan the widely used physical optics method.  相似文献   
8.
The first monochromatic X‐ray tomography experiments conducted at the Imaging and Medical beamline of the Australian Synchrotron are reported. The sample was a phantom comprising nylon line, Al wire and finer Cu wire twisted together. Data sets were collected at four different X‐ray energies. In order to quantitatively account for the experimental values obtained for the Hounsfield (or CT) number, it was necessary to consider various issues including the point‐spread function for the X‐ray imaging system and harmonic contamination of the X‐ray beam. The analysis and interpretation of the data includes detailed considerations of the resolution and efficiency of the CCD detector, calculations of the X‐ray spectrum prior to monochromatization, allowance for the response of the double‐crystal Si monochromator used (via X‐ray dynamical theory), as well as a thorough assessment of the role of X‐ray phase‐contrast effects. Computer simulations relating to the tomography experiments also provide valuable insights into these important issues. It was found that a significant discrepancy between theory and experiment for the Cu wire could be largely resolved in terms of the effect of the point‐spread function. The findings of this study are important in respect of any attempts to extract quantitative information from X‐ray tomography data, across a wide range of disciplines, including materials and life sciences.  相似文献   
9.
Analytical expressions for the spatial distribution of the spectral density and intensity of projection images are derived for a broad class of object transmission functions in the case of partially coherent Schell-model-type incident illumination. The expressions are linear with respect to the phase distribution in the transmitted wave. Associated methods for phase retrieval are discussed with the emphasis on a technique that allows simultaneous “automatic” phase retrieval and deconvolution of projection images of homogeneous objects by means of mutual cancellation at a specified defocus distance of the Fresnel diffraction effects and the image blurring due to the point-spread function of the imaging system.  相似文献   
10.
The generalized eikonal of a partially coherent paraxial wave is introduced via a differential equation describing the evolution of the time-averaged intensity. The theoretical formalism provides an analytical tool for the study of partially coherent imaging systems. It also makes possible quantitative phase retrieval and compositional mapping of weakly absorbing samples using phase-contrast imaging with broadband polychromatic radiation of known spectral distribution. An experimental demonstration is presented of the quantitative reconstruction of the projected thickness of a sample, given a phase-contrast image obtained using a polychromatic microfocus x-ray source.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号