首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   51篇
  免费   3篇
化学   33篇
晶体学   1篇
数学   11篇
物理学   9篇
  2022年   1篇
  2019年   1篇
  2018年   2篇
  2017年   1篇
  2016年   2篇
  2015年   1篇
  2014年   3篇
  2013年   2篇
  2012年   6篇
  2011年   6篇
  2010年   3篇
  2007年   2篇
  2004年   4篇
  2003年   2篇
  2002年   1篇
  2001年   1篇
  2000年   1篇
  1999年   1篇
  1997年   1篇
  1996年   3篇
  1995年   1篇
  1992年   1篇
  1991年   1篇
  1989年   1篇
  1987年   1篇
  1986年   1篇
  1982年   1篇
  1981年   2篇
  1980年   1篇
排序方式: 共有54条查询结果,搜索用时 93 毫秒
1.
2.
Atomization mechanisms of copper, platinum, iridium and manganese were studied by taking into account several parameters affecting the number of gaseous atoms present in the atomizer. The contributions of thermal expansion and diffusion to the dissipation rate of atoms were investigated. It was observed that the dissipation process cannot be described by diffusion only. Thermal expansion substantially contributed to the removal of atoms from the furnace and should not be ignored. It was possible to decide to what extent the several processes affect the concentration of the gaseous atoms at any time. From the Ea values obtained for the elements studied, the last step leading to gaseous atoms for copper, platinum and iridium was found to be the thermal dissociation of dimers in the gas phase; for manganese this was the dissociation of its monoxide in the gas phase.  相似文献   
3.
An algorithm is presented for reconstructing visible regions from visible edge segments in object space. This has applications in hidden surface algorithms operating on polyhedral scenes and in cartography. A special case of reconstruction can be formulated as a graph problem: Determine the faces of a straight-edge planar graph given in terms of its edges. This is accomplished inO(n logn) time using linear space for a graph withn edges, and is worst-case optimal. The graph may have separate components but the components must not contain each other. The general problem of reconstruction is then solved by applying our algorithm to each component in the containment relation.Research of this author is supported by the National Science Foundation under grant no. ECS-8351942, and by the Schlumberger-Doll Research Labs, Ridgefield, Connecticut.  相似文献   
4.
Coşkun N  Akman S 《Talanta》2004,64(2):496-500
Manganese in vitamin-minerals tablets was determined by solid sampling electrothermal atomic absorption spectrometry (SS-ETAAS) using three different calibration methods, namely calibration against aqueous standards, standard addition with aqueous standards on solid samples and calibration against solid certified standards. Samples were only finely ground and introduced directly into the furnace by means of solid autosampler system without any dissolving process. Effects of different calibration techniques, temperatures and heating rates of atomization and pyrolysis steps on the accuracy and precision of the analyte elements were investigated. After optimization of the experimental parameters, there is good agreement (at 95% confidence level) between the results obtained by solid sampling and those obtained by acid digestion of samples.  相似文献   
5.
In this study, a syringe was filled with silica gel loaded with 3-aminopropyltriethoxysilane, for the separation and preconcentration of copper, cadmium and chromium prior to their determination by graphite furnace atomic absorption spectrometry (GFAAS) in seawater. For this purpose, a syringe was filled with 0.5 g of modified silica gel and the sample solution was drawn into the syringe and ejected back again. The analyte elements were quantitatively retained at pH 5. Then, the elements sorbed by the silica gel were eluted with 2.0 M of HCl and determined by GFAAS. At optimum conditions, the recovery of Cu, Cd and Cr were 96-98%. Detection limits (3delta) were 6.6, 7.5 and 6.0 micro g L(-1) for Cu, Cd and Cr, respectively. The elements could be concentrated by drawing and discharging several portions of sample successively but eluting only once. Cu, Cd and Cr added to a seawater sample were quantitatively recovered (>95%) in the range of the 95% confidence level. The method proposed in this paper was compared with a column technique. Optimum experimental conditions, reproducibility, precision and recoveries of both techniques are the same, but the syringe technique is much faster, easier and more practical than the column technique. It is a portable system and allows one to make the sorption process in the source of sample. In addition, the risk of contamination is less than in the column technique.  相似文献   
6.
For practical guest–host applications, it is important to choose dyes with a high ability of orientation in the liquid crystal (LC) matrix. In this experimental work, two different azo-structured dyes (disperse yellow 3 and 7) were separately doped to each of two different nematic LCs (E7 and ZLI-1132). Their solubilities, textures, phase transition temperatures and order parameters were determined. At the second stage, single-walled carbon nanotubes (SWCNTs) in a small amount were separately added to each of these solutions, and the experiments were repeated as similar to the previous ones. The solubilities of dyes in the LC E7 were lower than those of ZLI-1132. Moreover, the highest order parameter value was attained with yellow 7 dye in ZLI-1132 nematic host. Co-use of nanoparticles (CNTs) as dopant resulted in notable increases in order parameters. These dyes and CNTs did not significantly destabilise the mesomorphic phase of nematic hosts. An appreciable change in textures was not monitored with addition of dopant(s). In addition, it was observed that the narrowing on the temperature range of the LC did not take place with the addition of dopants to the crystal; on the contrary, an increase was recorded.  相似文献   
7.
A Genetic Algorithm (GA) is an evolutionary computation technique inspired by the principle of biological evolution via natural selection. It employs the fundamental components of evolution, such as selection, mating, and mutation, which continue from generation to generation, creating better solutions as time progresses. Although it is mostly used as an optimization tool, GA enjoys a wide spectrum of applications in diverse fields such as engineering, medicine, and ecology, among others. In this study, we propose three different population size reduction methods for a typical GA optimization, aiming to increase efficiency. Additionally, we compare the accuracy and precision of these methods using Monte Carlo simulations.  相似文献   
8.
Tokman N  Akman S  Ozeroglu C 《Talanta》2004,63(3):699-703
In this study, a water-soluble polymer, polyvinylpyrrolidinone (PVP) having chelating functionalities was used for the preconcentration and separation of traces of Pb, Cu, Ve and Mn prior to their determination by graphite furnace atomic absorption spectrometry. For this purpose, the sample and the PVP solutions were mixed and the metal bound polymer was precipitated by adding the mixture onto acetone. The precipitate was separated by decantation and dissolved with water. By increasing the ratio of the volumes of sample to water used in dissolving the precipitate, the analyte elements were concentrated as needed. The concentration of trace elements was determined using graphite furnace atomic absorption spectrometry. The analyte elements in matrix free aqueous solutions were quantitatively recovered. The validity of the proposed method was checked with a standard reference material (NIST SRM 1577b bovine liver) and spiked fruit juice, sea water and mineral water samples. The analytical results were found to be in good agreement with certified and added values. Detection limits (3δ) were 1.7, 3.6 and 4.1 μg l−1 for Pb, Cu and Mn, respectively, using 10 μl of sample volume. The method is novel and can be characterized by rapidity, simplicity, quantitative recovery and high reproducibility.  相似文献   
9.
Akman S  Tokman N 《Talanta》2003,60(1):199-204
Lead and nickel were concentrated and separated after sorbing on Chromosorb-107 filled in a syringe prior to their determination by electrothermal atomic absorption spectrometry. To retain the analytes, the sample solution treated with or without ammonium pyrolidine dithiocarbamate (APDC) was drawn into the syringe filled with Chromosorb-107 and discharged back manually. Then the analyte elements were eluted by drawing and discharging the suitable eluent. The optimum experimental conditions for quantitative recoveries of analytes (amount of sorbent, pH of sample, concentration and kind of eluent, flow rates of sample and eluent and adding of the effect of complexing agent) were investigated. Nickel was quantitatively retained at pH6 irrespective of whether it was complexed with APDC while the quantitative sorption of lead was achieved at pH8 only if it was treated with APDC prior to passing through the sorbent. The lead and nickel retained on the sorbent were eluted drawing and discharging 4.5 M HNO(3), respectively. If the concentration of analyte elements in the sample were too low to be detected, then they were concentrated by increasing the ratio of sample value to eluent volume as needed. The lead and nickel in spiked sea-water samples and in certified reference Apple-Leaves (NIST SRM 1515) standards were quantitatively (95%) recovered with R.S.D. of around +/-2%.  相似文献   
10.
In this study, proper orthogonal decomposition (POD) method is applied to diffusion–convection–reaction equation, which is discretized using space–time discontinuous Galerkin (dG) method. We provide estimates for POD truncation error in dG-energy norm, dG-elliptic projection, and space–time projection. Using these new estimates, we analyze the error between the dG and the POD solution, and the error between the exact and the POD solution. Numerical results, which are consistent with theoretical convergence rates, are presented.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号