首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   14篇
  免费   0篇
化学   13篇
数学   1篇
  2020年   1篇
  2004年   1篇
  2000年   1篇
  1993年   1篇
  1991年   2篇
  1990年   2篇
  1987年   1篇
  1986年   1篇
  1985年   2篇
  1984年   1篇
  1971年   1篇
排序方式: 共有14条查询结果,搜索用时 15 毫秒
1.
Low levels of carbonate and nitrite contained in inorganic matrices were determined by ion chromatography on an Asahipak ODP-50 poly(vinyl alcohol) gel-based reversed-phase column. With an acidic mobile phase, inorganic matrix anions and cations eluted near the void volume of the column, whereas carbonate and nitrite were retained and separated completely from the matrix ions. After the separation column, the peak response was enhanced using a cation-exchange hollow fibre and 25 mM sodium sulphate or alkaline enhancers. Sea-water samples can be applied directly for the determination of carbonate and added nitrite at ppm levels. The maximum sample volume that can be loaded on the column without peak deformation depended on the pH of the sample solution and the sulphuric acid concentration in the eluent. A 50 μl sea-water sample was applicable with a 2.5 mM acid eluent.  相似文献   
2.
We discuss puzzles of prisoners and hats with infinitely many prisoners and more than two hat colors. Assuming that the set of hat colors is equipped with a commutative group structure, we prove strategic equivalence among puzzles of several protocols with countably many prisoners.  相似文献   
3.
Summary A low-capacity, anion-exchange, porous-polymer resin was used as the packing material in a microbore column. Using a phosphate buffer containing various organic modifiers, retention behavior of substituted benzoic acid isomers with amino, chloro, methyl, nitro and carboxylic groups was investigated. The effect of ethanol, acetonitrile and sodium dodecylsulfate used as organic modifiers on the retention behavior at various eluent pH values was studies and optimum separations of the positional isomers reported.  相似文献   
4.
Liquid crystalline polyacrylates (LCPAs) are evaluated as stationary phases for capillary gas chromatography (CGC). Aromatic hydrocarbons as well as polar isomeric compounds are used as test solutes to compare the polarity of the LCPAs with a conventional polysiloxane column and a Carbowax 20M column. The relative polarity of the columns with respect to change in the lateral and terminal substituents is also discussed. Lateral substitution, polarity of the terminal group, together with the solute size, affect the LCPA selectivity.  相似文献   
5.
6.
The unique characteristics of a bonded-fluoroalkylsilane column, Fluofix, are described by comparison with those of a bonded octylsilane column, C8, in the reversed-phase chromatography of aromatic hydrocarbons. The selectivity of homologous aromatics on the fluorinated column varied with the methanol concentration in the eluent. At a larger proportion of methanol than 80:20 (v/v) the larger aromatics eluted faster than the smaller ones. However, with less methanol, the aromatics were eluted in order of their molecular size, as usually reported for a conventional hydrocarbonaceous column. A dependence of the retention mechanism on the composition of the eluent was suggested by the decrease in the entropy-enthalpy compensation temperature, beta, with increase of methanol concentration in the eluent. In order to explain the concentration dependence of the retention, the molecular interaction energy in the retention process was calculated by computer simulation. The interaction energy between aromatics and the stationary ligand on the Fluofix column was smaller than that on the C8 column and comparable to the interaction energy between the aromatics and methanol. At higher methanol concentrations, solute-fluorinated ligand complex formation was obstructed by the methanol molecules solvating the solute, reducing the retention of the larger aromatics.  相似文献   
7.
A series of 1-phenyl-3-methyl-5-pyrazolone (PMP) aldose was eluted on a C18 column with an acetonitrile-phosphate buffer over the range of pH 2-10 in reversed phase liquid chromatography. The relationship between the retention factor, k, and the eluent pH was expressed by an equilibrium scheme representing the probable retention process. The experimental data were fitted to the correlation curve drawn according to the equation containing the formation of the hydrogen bond with a hydroxonium ion in the eluent and the ionization of the oxygen atoms in the pyrazolone rings of the solute.The conformational changes of PMP-aldose according with the eluent pH were corroborated by computer-aided molecular modeling using quantum chemical calculations. The retention behavior was elucidated as a function of the geometrical feature of the PMP-aldose.  相似文献   
8.
Summary Poly(vinyl alcohol) (PVA) gel shows ionic retention properties for common inorganic anions when an acidic eluent is used. The ionic property of the PVA gel is due to the proton-acceptable nitrogen atoms of the cross-linking agent and the carboxylic residues being comprised in the gel matrix. The extent of the net charge on the gel surface depends on the pH of the eluent. At a pH ranging from 2.3 to 5.3, the PVA gel behaves as a weak anion exchanger with very low ion-exchange capacity. At these conditions four UV-absorbing inorganic anions (bromate, bromide, nitrate, and nitrite) are separated by eluting with aqueous sulfuric acid. Alkyl groups introduced on the gel surface hinder the ionized solute molecules from accessing to the positively charged functional groups on the gel surface. A neutral solute (HNO2) is retained with non-ionic interactions.  相似文献   
9.
Summary New polyacrylate liquid crystalline compounds were coated onto glass or fused-silica capillary columns as stationary phases and applied to supercritical fluid chromatography. These stationary phases, were very stable: no bleeding was observed at 200°C and up to 200kg/cm2 pressures of carbon dioxide mobile phase. The wide working range of the capillary column was extended below the g-n transition temperature. Isomeric compounds such as - and -methoxynaphthalene, anthracene and phenanthrene and several phenolic compounds were separated.  相似文献   
10.
Novel monomeric and polymeric liquid crystalline compounds were synthesized as stationary phases for gas chromatography (GC) and supercritical fluid chromatography (SFC). Monomeric liquid crystalline compounds were used in packed column gas chromatography for the separation of isomeric aromatic compounds and insect sex pheromones. Liquid crystalline polymers possess long nematic ranges and a uniform coating was easily achieved in glass and fused silica capillaries, which could stand temperatures up to 250°C in GC and pressures of 200 MPa at 160°C in SFC. The columns provide excellent selectivity and resolution for fused ring aromatic compounds such as the isomers anthracene and phenanthrene or triphenylene and chrysene.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号