首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   124篇
  免费   10篇
  国内免费   2篇
化学   110篇
晶体学   1篇
数学   9篇
物理学   16篇
  2023年   2篇
  2021年   2篇
  2020年   2篇
  2019年   3篇
  2018年   2篇
  2017年   3篇
  2016年   4篇
  2015年   6篇
  2014年   5篇
  2013年   7篇
  2012年   8篇
  2011年   15篇
  2010年   6篇
  2009年   5篇
  2008年   13篇
  2007年   4篇
  2006年   7篇
  2005年   10篇
  2004年   5篇
  2003年   4篇
  2002年   5篇
  2000年   3篇
  1996年   2篇
  1995年   3篇
  1992年   1篇
  1991年   3篇
  1990年   1篇
  1987年   2篇
  1985年   2篇
  1981年   1篇
排序方式: 共有136条查询结果,搜索用时 218 毫秒
1.
A series of noncyclic neutral ionophores has been synthesized by the reaction of oligoethylene glycol dihalides with 8-quinolinol. Complexation properties for alkali metal picrates were evaluated from solvent extraction and bulk liquid membrane transport experiments. Complexation profiles of the newly synthesized ionophores with a hexyl chain were similar to those of their homologues without the hexyl chain in the extraction experiments. Among them, the pentaethylene glycol derivatives showed the highest extraction efficiency and selectivity towards potassium ion. From the1H NMR spectra (400 MHz), the change in chemical shifts of the aromatic protons upon the addition of alkali metal thiocyanates suggested the existence of a stabilization effect which is caused by intramolecular stacking conformations between the quinoline rings during complexation. Aryl stacking interactions depend on the size of the cations and on the chain length of the oligoethylene glycol. The relationship between transport ability towards alkali metal cations and lipophilicity of these ionophores is also discussed.  相似文献   
2.
We have developed a new magneto-optical measurement system using a rotational cavity system equipped with a millimeter vector network analyzer and a 14 T solenoid type super conducting magnet. The measurement can be performed in the transmission configuration down to 1.6 K. The results of the precise angular dependence measurement of quasi-one-dimensional organic conductor (DMET)2I3 using the new system are shown, and its Fermi surface will be discussed in connection with the previous reports.  相似文献   
3.
TiO2(B) nanowires and TiO2 anatase nanowires were synthesized by the hydrothermal processing in 10 M NaOH aq. at 150 °C followed by the post-heat treatment at 300-800 °C. As-synthesized Na-free titanate nanowires (prepared by the hydrothermal treatment and repeated ion exchanging by HCl (aq.) were transformed into TiO2(B) structure with maintaining 1-D morphology at 300-500 °C, and further transformed into anatase structure at 600-800 °C with keeping 1-D shape. At 900 °C, they transformed into rod-shaped rutile grains. Microstructure of these 1-D TiO2 nanomaterials is reported.  相似文献   
4.
Brown coals have a considerable number of acidic functional groups of which the main component is carboxyl groups, and the acidity has a wide distribution. In this paper, changes of the acidity distribution were examined by aqueous titration when brown coal was heat-treated to control its acidity distribution. For Loy Yang brown coal from Australia dried at 50 degrees C under vacuum (LY50), the acid dissociation constant, Ka, was distributed over a wide pKa range between 2 and 9. Then, using Gaussian functions, the acidity distribution was divided into four groups, which were characterized by average pKa values: average pKa value of 3.8 (hereafter referred to as Group A), 5.2 (Group B), 6.8 (Group C), and 8.3 (Group D). Among them, Groups A, B, and C were assigned to carboxyl groups. From the changes of the number of carboxyl groups when brown coal was heat-treated up to 400 degrees C, it was found that the way of decrease was different among these acidic groups. The decrease of the amount of carboxyl groups in Group C was significant, and at 325 degrees C most of them disappeared. On the other hand, the carboxyl groups in Group A remained even at a high temperature of 400 degrees C. We estimated approximately the structures around carboxyl groups for LY50 and their structural changes by heat treatment using the known pKa values for simple carboxylic acids and the pKa values calculated by the MOPAC program for complicated carboxylic acids.  相似文献   
5.
Liu Z  Otsuka K  Terabe S  Motokawa M  Tanaka N 《Electrophoresis》2002,23(17):2973-2981
The physical adsorption method proposed previously has been successfully applied to a monolithic silica column. By virtue of the physical adsorption, a chiral stationary phase of avidin was prepared onto the silica monolith. The phase ratio of resulting stationary phase was evaluated with frontal analysis. The method proved to be comparable in phase ratio to the chemical bonding methods used in high-performance liquid chromatography (HPLC). Enantiomer separations were carried out in capillary electrochromatography (CEC) and capillary liquid chromatography (CLC) modes. Due to its larger phase ratio, the resulting column showed more powerful separation capability as compared to open-tubular CEC (OTCEC). Twelve chiral compounds were baseline-resolved. The resulting column showed high separation efficiency, with average theoretical plate numbers of 66 000/m for CLC and 122 000/m for CEC. Good reproducibility was observed, with RSD value less than 1.3% for retention time, retention factor and separation factor, and less than 6.6% for plate counts and resolution (n = 40). Fast separations were achieved with a short column. The test enantiomers were baseline-resolved within 4 min under CLC and CEC modes. In addition, field-enhanced sample injection (FESI) was coupled to CLC as well as CEC to improve the detection sensitivity.  相似文献   
6.
An interconnecting technique, the "PDMS connection method", for quartz microchips in a high-pressure system is presented. The connection between quartz microchips is an essential technology for modular microfluidic devices, such as microchip-HPLC. PDMS was applied to the seal material, being spread on the seal side of the chips, and set into the metal housing. The characteristics of the PDMS connection method concerning pressure resistance and the extension of the peak were examined. The experimental results showed a good seal at 5 MPa, which seem to be sufficient for realizing microchip-HPLC utilizing a monolithic silica capillary column as a separation medium. The influence of the extra column effect on chromatographic separation was almost the same as in the case using a commercial union fitting. In addition, the PDMS connection enabled the detachability of chip-based modules with user-friendliness. Our experimental findings suggest that the novel PDMS connection method can possibly be applied as a generic technology in high-pressure microTAS.  相似文献   
7.
Reduction of through-pore size and skeleton size of a monolithic silica column was attempted to provide high separation efficiency in a short time. Monolithic silica columns were prepared to have various sizes of skeletons (approximately 1-2 microm) and through-pores (approximately 2-8 microm) in a fused-silica capillary (50-200 microm I.D.). The columns were evaluated in HPLC after derivatization to C18 phase. It was possible to prepare monolithic silica structures in capillaries of up to 200 microm I.D. from a mixture of tetramethoxysilane and methyltrimethoxysilane. As expected, a monolithic silica column with smaller domain size showed higher column efficiency and higher pressure drop. High external porosity (> 80%) and large through-pores resulted in high permeability (K = 8 x 10(-14) -1.3 x 10(-12) m2) that was 2-30 times higher than that of a column packed with 5-mirom silica particles. The monolithic silica columns prepared in capillaries produced a plate height of about 8-12 microm with an 80% aqueous acetonitrile mobile phase at a linear velocity of 1 mm/s. Separation impedance, E, was found to be as low as 100 under optimum conditions, a value about an order of magnitude lower than reported for conventional columns packed with 5-microm particles. Although a column with smaller domain size generally resulted in higher separation impedance and the lower total performance, the monolithic silica columns showed performance beyond the limit of conventional particle-packed columns under pressure-driven conditions.  相似文献   
8.
By employing small-angle neutron scattering (SANS), we investigated the microstructures of, poly(N-isopropylacrylamide) (PNIPA)-block-poly(ethylene glycol) (PEG) (NE) in deuterated water D2O, as related to macroscopic behaviors of fluidity, turbidity and synerisis. SANS revealed following results: (i) microphase separation occurs at around above 17 °C in a temperature range of transparent sol below 30 °C. In the microdomain appeared in the transparent sol state, both block chains of PNIPA and PEG are swollen by water; (ii) for the NE solution of polymer concentration Wp > 3.5% (w/v), corresponding to opaque gel above 30 °C, a percolated structure, i.e., network-like domain is formed by NE as a result of macrophase separation due to dehydration of the PNIPA chains. As the temperature increases toward 40 °C, the network domain is squeezed along a direction parallel to the NE interface, which leads to increase of the interfacial thickness given by swollen PEG chains and to the macroscopic synerisis behavior.  相似文献   
9.
We have developed miniaturized multi-channel high-performance liquid chromatography (HPLC) system. With this system, we can simultaneously separate multiple samples, using a single high-pressure gradient pump, a chip-based sample injection unit, a monolithic silica capillary column array, and a multi-channel UV detection unit based on fiber optics. The injection unit has a simplified structure composed of brass housing and a quartz microchip having microchannels and access ports, which enable a direct injection of sample to multi-channel by commercial multichannel micropipette. Moreover, that possesses a function of microvalve, and on-chip definition of sample injection plugs achieved with a cross channel injection method, providing each column of monolithic silica capillary array. The substances in channels were simultaneously detected with UV having multiple cells. Standard samples were analyzed for characterizing newly developed system, and sharp peaks were obtained with reproducibility data of < 0.9% (R.S.D.). Analysis of tryptic digestion of casein was also employed. These results show that the novel multi-channel HPLC system has the benefits for the high-throughput analysis in the post-genomic analysis/combinatorial chemistry.  相似文献   
10.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号