首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   39篇
  免费   0篇
化学   15篇
力学   5篇
数学   4篇
物理学   15篇
  2016年   1篇
  2015年   2篇
  2013年   2篇
  2011年   3篇
  2009年   4篇
  2008年   1篇
  2007年   1篇
  2006年   4篇
  2005年   2篇
  2004年   1篇
  2003年   1篇
  2002年   4篇
  2001年   2篇
  2000年   1篇
  1999年   1篇
  1996年   1篇
  1994年   1篇
  1993年   1篇
  1992年   1篇
  1984年   1篇
  1982年   1篇
  1978年   1篇
  1976年   1篇
  1967年   1篇
排序方式: 共有39条查询结果,搜索用时 94 毫秒
1.
2.
We present an optical frequency divider based on a 200 MHz repetition rate Er:fiber mode-locked laser that, when locked to a stable optical frequency reference, generates microwave signals with absolute phase noise that is equal to or better than cryogenic microwave oscillators. At 1 Hz offset from a 10 GHz carrier, the phase noise is below -100 dBc/Hz, limited by the optical reference. For offset frequencies >10 kHz, the phase noise is shot noise limited at -145 dBc/Hz. An analysis of the contribution of the residual noise from the Er:fiber optical frequency divider is also presented.  相似文献   
3.
Let V be a vector space of dimension n over any field F. Extreme values for the possible dimension of a linear subspace of EndF(V) with a particular property are considered in two specific cases. It is shown that if E1 is a subspace of EndF(V) and there exists an endomorphism g of V, not in E1, such that for every hyperplane H of V some element of E1 agrees with g on H, then E1 has dimension at least . This answers a question that was posed by Szechtman in 2003. It is also shown that a linear subspace of Mn(F) in which no element possesses a non-zero eigenvalue in F may have dimension at most . The connection between these two properties, which arises from duality considerations, is discussed.  相似文献   
4.
The growth and chemisorptive properties of monolayer films of Ag and Au deposited on both the Pt(111) and the stepped Pt(553) surfaces were studied using Auger electron spectroscopy (AES), thermal desorption spectroscopy (TDS), and low energy electron diffraction (LEED). AES studies indicate that the growth of Au on Pt(111) and Pt(553) and Ag on Pt(111) proceeds via a Stranski-Krastanov mechanism, whereas the growth of Ag on the Pt(553) surface follows a Volmer-Weber mechanism. Au dissolves into the Pt crystal bulk at temperatures > 800 K, whereas Ag desorbs at temperatures > 900 K. TDS studies of Ag-covered Pt surfaces indicate that the AgPt bond (283 kJ mol?1) is ~25 kJ mol?1 stronger than the AgAg bond (254 kJ mol?1). On the Pt(553) surface the Au atoms are uniformly distributed between terrace and step sites, but Ag preferentially segregates to the terraces. The decrease in CO adsorption on the Pt crystal surfaces is in direct proportion to the Ag or Au coverage. No CO adsorption could be detected for Ag or Au coverages above one monolayer at 300 K and 10?8 Torr. The heat of adsorption of CO on Pt is unaltered by the presence of Ag or Au.  相似文献   
5.
Acoustical time reversal mirrors have been shown to provide a highly accurate means of studying and focusing on acoustical sources. The DORT method is a derivation of the time reversal process, which allows for focusing on multiple targets. An important step in this process is the determination of the number of targets or sources present. This is achieved by examining the eigenvalues of the time reversal operator (TRO). The number of significant eigenvalues is then chosen as the number of sources present. However, as mentioned in [N. Mordant, C. Prada, and M. Fink, J. Acoust. Soc. Am. 105, 2634-2642 (1999) and C. Prada, M. Tanter, and M. Fink, in Proceedings of the IEEE Symposium, 1997, pp. 679-683], factors such as low signal to noise ratio (SNR), small data sample, array configuration and the target location may result in the eigenvalues corresponding to the targets no longer being distinguishable from the background noise eigenvalues. This paper proposes a robust method of automatically determining the number of targets even in the presence of a small number of snapshots. For white Gaussian noise, the profile of the ordered eigenvalues is seen to fit an exponential law. The observed eigenvalues are then compared to this model and a mismatch is detected between the observed profile and the noise-only model. The index of the mismatch gives the number of scatterers present.  相似文献   
6.
Given a field F and integer n≥3, we introduce an invariant sn (F) which is defined by examining the vanishing of subspaces of alternating bilinear forms on 2-dimensional subspaces of vector spaces. This invariant arises when we calculate the largest dimension of a subspace of n?×?n skew-symmetric matrices over F which contains no elements of rank 2. We show how to calculate sn (F) for various families of field F, including finite fields. We also prove the existence of large subgroups of the commutator subgroup of certain p-groups of class 2 which contain no non-identity commutators.  相似文献   
7.
Doppler Global Velocimetry (DGV) is a whole-field measurement technique which has attracted significant interest from the fluid-flow research community since its introduction in 1991. Practical implementations of the methodology have focused on two principal laser light sources: the argon ion laser, applied to steady state or slowly varying flows; and the pulsed neodymium YAG laser for the measurement of instantaneous velocity fields. However, the emphasis in the published literature has been very much on research using the argon laser. This paper reports the application of a Q-switched, injection-seeded neodymium YAG laser to the proven Oxford DGV system, and the use of this combination in a short duration unsteady high-speed flow. The pertinent characteristics of the apparatus are described, and the impact of these on the integrity of the resulting velocity measurements is presented. Adaptations to the commercial laser system that make it suitable for application to the measurement of transient high-speed flows are described. Finally, the application of this system to a short duration unsteady flow is described. This application is based on the flow found in a new type of transdermal drug delivery device, where particles of the drug material are projected at high speed through the skin. Whole-field velocities are recorded, and values as high as 800 m/s are evident.  相似文献   
8.
The synthesis of amidourea-based colorimetric anion sensors 1 and 2 and the evaluation of these sensors using anions such as acetate , fluoride (F), hydrogen phosphate and hydrogenpyrophosphate (pyr) in DMSO is described. While 1 has a single amidourea moiety, 2 has two such receptors incorporated into a lower-rim 1,3-disubstituted calix[4]arene scaffold. Whilst both sensors gave rise to red shifts in their absorption spectra upon anion recognition, the sensing of F and pyr gave rise to large changes with concomitant colour changes from yellow to purple, which were visible to the naked eye.  相似文献   
9.
Abstract. Transdermal powdered drug delivery involves the propulsion of solid drug particles into the skin by means of high-speed gas-particle flow. The fluid dynamics of this technology have been investigated in devices consisting of a convergent-divergent nozzle located downstream of a bursting membrane, which serves both to initiate gas flow (functioning as the diaphragm of a shock tube) and to retain the drug particles before actuation. Pressure surveys of flow in devices with contoured nozzles of relatively low exit-to-throat area ratio and a conical nozzle of higher area ratio have indicated a starting process of approximately 200 s typical duration, followed by a quasi-steady supersonic flow. The velocity of drug particles exiting the contoured nozzles was measured at up to 1050 m/s, indicating that particle acceleration took place primarily in the quasi-steady flow. In the conical nozzle, which had larger exit area ratio, the quasi-steady nozzle flow was found to be overexpanded, resulting in a shock system within the nozzle. Particles were typically delivered by these nozzles at 400 m/s, suggesting that the starting process and the quasi-steady shock processed flow are both responsible for acceleration of the particle payload. The larger exit area of the conical nozzle tested enables drug delivery over a larger target disc, which may be advantageous. Received 12 March 2000 / Accepted 8 June 2000  相似文献   
10.
Fundamental science, as well as all communications and navigation systems, are heavily reliant on the phase, timing, and synchronization provided by low‐noise and agile frequency sources. Although research into varied photonic and electronic schemes have strived to improve upon the spectral purity of microwave and millimeter‐wave signals, the reliance on conventional electronic synthesis for tuning has resulted in limited progress in broadband sources. Using a digital‐photonic synthesizer architecture that derives its time‐base from a high‐stability optical reference cavity, we generate frequency‐agile and wideband microwave signals with exceptional dynamic range and with a fractional frequency instability of 1 × 10−15 at 1 s. The presented architecture demonstrates digitally controlled, user defined and broadband frequency tuning from RF to 100 GHz with orders‐of‐magnitude improvement in noise performance over room‐temperature electronic wide‐bandwidth synthesis schemes.

  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号