首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   23篇
  免费   0篇
化学   12篇
力学   5篇
数学   1篇
物理学   5篇
  2014年   1篇
  2013年   2篇
  2011年   1篇
  2010年   1篇
  2009年   1篇
  2008年   1篇
  2007年   2篇
  2006年   1篇
  2005年   2篇
  2004年   3篇
  2003年   1篇
  2002年   3篇
  2001年   1篇
  2000年   2篇
  1989年   1篇
排序方式: 共有23条查询结果,搜索用时 20 毫秒
1.
A sensitive and entirely automated solid-phase extraction/liquid chromatography/electrospray ionization tandem mass spectrometric (SPE/LC/ESI-MS/MS) method was developed and validated for the determination of eserine N-oxide (ENO), a cholinesterase inhibitor-like physostigmine in human plasma, for use in pharmacokinetic studies. ENO is light-sensitive and the use of a fully on-line process increased the reliability of the assay. Plasma samples previously mixed with neostigmine bromide to prevent in vitro degradation, and tacrine as internal standard (IS), were directly injected into the SPE/LC/ESI-MS/MS system. MS software piloted the overall system. MS/MS detection of ENO and the IS was performed in the positive ion ESI mode using multiple reaction monitoring. The linear calibration curve for ENO ranged from 25 pg ml(-1) to 12.5 ng ml(-1). The limit of quantitation was 25 pg ml(-1) with 250 microl of plasma injected. Precision, accuracy and stability tests were within the acceptable range and just one analyst is required to analyze 50 unknown samples a day five days per week, from the preparation of the samples (i.e. thawing and centrifugation) to data processing. A pilot pharmacokinetic study in three healthy volunteers treated with 4.5 mg of ENO (Génésérine3((R))) showed that the method was suitable for pharmacokinetic studies in humans.  相似文献   
2.
The analytic equivalence of two operators is a generalization of similarity. We prove that under some conditions the analytic equivalence between two Hilbert space operatorsT andR implies the similarity of their restrictions on generalized ranges. We also prove that, in certain cases, the similarity ofT to a contraction implies that ofR. An improvement of a well-known criterion of similarity to an isometry due to Sz.-Nagy is given and an extension of a result of Apostol is obtained.  相似文献   
3.
4.
A systematic study of the rheological properties of solutions of non-motile microalgae (Chlorella vulgaris CCAP 211-19) in a wide range of volume fractions is presented. As the volume fraction is gradually increased, several rheological regimes are observed. At low volume fractions (but yet beyond the Einstein diluted limit), the suspensions display a Newtonian rheological behaviour and the volume fraction dependence of the viscosity can be well described by the Quemada model (Quemada, Eur Phys J Appl Phys 1:119–127, 1997). For intermediate values of the volume fraction, a shear thinning behaviour is observed and the volume fraction dependence of the viscosity can be described by the Simha model (Simha, J Appl Phys 23:1020–1024, 1952). For the largest values of the volume fraction investigated, an apparent yield stress behaviour is observed. Increasing and decreasing stress ramps within this range of volume fractions indicate a thixotropic behaviour as well. The rheological behaviour observed within the high concentration regime bears similarities with the measurements performed by Heymann and Aksel (Phys Rev E 75:021505, 2007) on polymethyl methacrylate suspensions: irreversible flow behaviour (upon increasing/decreasing stresses) and dependence of the flow curve on the characteristic time of forcing (the averaging time per stress values). All these findings indicate a behaviour of the microalgae suspensions similar to that of suspensions of rigid particles. A deeper insight into the physical mechanisms underlying the shear thinning and the apparent yield stress regime is obtained by an in situ analysis of the microscopic flow of the suspension under shear. The shear thinning regime is associated to the formation of cell aggregates (flocs). Based on the Voronoi analysis of the correlation between the cell distribution and cell sizes, we suggest that the repulsive electrostatic interactions are responsible for this microscale organisation. The apparent yield stress regime originates in the formation of large-scale cell aggregates which behave as rigid plugs leading to a maximally random jammed state.  相似文献   
5.
Courcot  D.  Pruvost  C.  Zhilinskaya  E. A.  Aboukaïs  A. 《Kinetics and Catalysis》2004,45(4):580-588
Different oxide carriers (TiO2 and ZrO2) as supports for low amounts of Cu2+ and K+ species (2 wt % as equivalent oxide) were tested in the catalytic oxidation of carbon black. The K-Cu/oxide catalysts were shown to have a lower soot combustion temperature than K/oxide, Cu/oxide, and pure oxide carriers. The K-Cu/ZrO2 catalyst was found to be the most active; it exhibited activity in a loose contact nearly similar to that obtained in a tight contact mode. Physicochemical characterization by EPR, XPS, and TPR revealed the interaction of K+ species with Cu2+ species and the ZrO2 carrier in K-Cu/ZrO2 as well as a strongly distorted Cu2+ species on the ZrO2 surface. The potassium ions ensure promoting effects towards the contact between the carbon black and the catalyst surface. Although potassium ions were found to lower the reducibility of the cupric oxide species, the oxidation rate of carbon black increased in the presence of K/oxide and K-Cu/oxide.  相似文献   
6.
7.
Besides liquid chromatographic (LC)/UV methods adapted to therapeutic drug monitoring, there is still a need for more powerful techniques that can be used for pharmacological research and clinical purposes. We developed an LC method coupled with tandem mass spectrometry (MS/MS) to separate, detect and quantify with high sensitivity the nucleoside analogues used in multitherapies (zidovudine, stavudine, zalcitabine, didanosine, lamivudine and abacavir) in plasma and in the intracellular medium. We worked on two essential issues: (i) the need to use two ionization modes in order to achieve the best sensitivity, which leads to the optimization of the chromatographic separation of drugs detected in the positive ionization mode and drugs detected in the negative ionization mode, and (ii) the need to optimize the extraction step in order to enhance sample recovery. The peripheral blood mononuclear cells were lysed in Tris buffer-MeOH. A clean-up procedure was performed by solid-phase extraction only for plasma samples. The LC separation was carried out on a Zorbax Stable Bond C(18) column followed by MS/MS analysis after electrospray ionization in either the negative or positive mode. The positive ionization mode was applied at the beginning of the run to detect zalcitabine and lamivudine, then the ionization mode was changed to negative for the detection of didanosine, stavudine, internal standard and zidovudine. The calibration range for all the analytes was 0.5-200 ng ml(-1). The recoveries were between 64 and 90%, with coefficients of variation (CVs) lower than 15%. The inaccuracy (bias) was +/-15% with CVs always lower than 12%. The analytes were stable at room temperature and in the extraction solvent for at least 24 h, after storage at -80 degrees C for 3 months, after three freeze-thaw cycles and in the injection solvent after 48 h at 4 degrees C. Together with the measurement of intracellular triphosphorylated metabolites thanks to the powerful plasma and intracellular assay method for intact drugs, it is possible to describe the behaviour of nucleoside analogues against HIV through plasma pharmacokinetics, cell membrane diffusion including drug transport involvement, and also the intracellular metabolism.  相似文献   
8.
We report on the quantitative study of guiding of cold rubidium atoms in a Laguerre-Gaussian laser mode LG0 l, which is holographically prepared using a spatial light modulator. We have measured the guiding efficiency (up to 25%) and studied the variations versus l, the order of the mode and versus the laser detuning. We interpret the observed behavior by using a two-dimensional trap model and by calculating the capture efficiency of the initial atomic cloud by the dipole guide.  相似文献   
9.
10.
Nd1.67Sr0.33NiO4 polycrystals have been prepared by modified sol–gel method and subsequent annealing. X-ray diffraction analysis, electrical resistivity, magnetic susceptibility and thermal magnetisation have been measured. Rietveld analyses show a tetragonal or pseudo-tetragonal K2NiF4-type structure. The resistivity measurements present a change in conduction mode close to 230 K, which corresponds to the charge ordering temperature. Below this temperature, the material adopts a variable range hopping conduction mode; and above, the conduction follows adiabatic thermal activated mode. The magnetic measurements show paramagnetic behaviour in the range of 80–300 K. Moreover, the magnetic susceptibility data show a sign of the charge ordering transition about 230 K.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号