首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   33篇
  免费   0篇
化学   9篇
力学   2篇
数学   1篇
物理学   21篇
  2013年   1篇
  2004年   1篇
  2003年   1篇
  1999年   5篇
  1996年   1篇
  1995年   2篇
  1994年   2篇
  1993年   4篇
  1992年   2篇
  1991年   1篇
  1990年   1篇
  1988年   2篇
  1986年   2篇
  1979年   1篇
  1976年   2篇
  1974年   2篇
  1971年   3篇
排序方式: 共有33条查询结果,搜索用时 15 毫秒
1.
2.
3.
4.
5.
Summary Pressure effects in the capillary flow of a single sample of poly(methyl methacrylate),M v = 1.33 · 105, were evaluated. The length/diameter ratios of the different capillaries used varied from 4 to 100. The tests were made with an Instron rheometer in the range 160–250 °C. The pressure-viscosity model, derived from the free volume-WLF equation, was used to pressure correct the capillary data. The corrected data agreed well with data obtained at atmospheric pressure using aWeissenberg rheogoniometer. A derived expression to calculate an increase in the flow activation energy with increasing stress predicts the observed increase in activation energy.
Zusammenfassung Druckeffekte bei der Kapillarströmung einer einzelnen Polymethylmethacrylat-ProbeM v = 1,33 · 105 werden abgeschätzt. Die Längen/Durchmesserverhältnisse der verschiedenen verwendeten Kapillaren variierten zwischen 4 und 100. Im Temperaturbereich zwischen 160 und 250 °C wurden die Versuche mit einem Instron-Rheometer durchgeführt. Das Druck-Viskositätsmodell, das aus der WLF-Gleichung abgeleitet war, wurde zur Druckkorrektur der Kapillardaten verwendet. Die korrigierten Werte zeigten eine gute Übereinstimmung mit den Werten, die bei Atmosphärendruck mit Hilfe einesWeissenberg-Rheogoniometers gewonnen worden waren. Ein abgeleiteter Ausdruck zur Berechnung des Anstiegs der Strömungs-Aktivierungsenergie mit steigender Spannung sagt den beobachteten Anstieg in der Aktivierungsenergie voraus.


On leave from Montecatini Edison, Milan (Italy).  相似文献   
6.
Fast atom bombardment, combined with high-energy collision-induced tandem mass spectrometry, has been used to investigate gas-phase metal-ion interactions with captopril, enalaprilat and lisinopril, all angiotensin-converting enzyme inhibitors.Suggestions for the location of metal-binding sites are presented. For captopril, metal binding occurs most likely at both the sulphur and the nitrogen atom. For enalaprilat and lisinopril, binding preferably occurs at the amine nitrogen. Copyright 1999 John Wiley & Sons, Ltd.  相似文献   
7.
[reaction: see text] The synthesis of various tetrasubstituted alkenes and dienes in a regio- and stereocontrolled manner is described. This three-component coupling strategy involves the addition of Grignard reagents to propargyl alcohols followed by palladium(0)-mediated cross-coupling with aryl or vinyl halides. This protocol has been applied to the synthesis of (Z)-Tamoxifen and related mimics.  相似文献   
8.
9.
General expressions for determining the pressure coefficient and axial distribution of the viscosity and pressure in capillary flow are derived for Newtonian and shear-thinning fluids. The pressure-dependent viscosity model is obtained from the WLF equation as derived from Doolittle's free volume theory. The model has also been derived from Eyring's hole theory for viscosity. Poiseuille's equation is modified to correct for the pressure effect on viscosity. A Newtonian, low-molecular-weight polystyrene and a shear-thinning, high-molecular-weight polystyrene were tested in an Instron capillary rheometer. The axial velocity distribution was found to be negligibly affected by pressure whereas the viscosity was shown to increase markedly with a decrease in volume. The resulting pressure effects on the viscosity of both samples were analyzed by using the derived expressions.  相似文献   
10.
A procedure is explained to determined the amount of several pairs of diametrical loads applied to the outside boundary of a ring when stresses at selected points of the inside or outside boundaries are known. Coefficients of influence are used, following an approach similar to the one presented in a previous paper. Examples of application are given and the possible increase in precision is shown when the number of points of measurements is larger than the number of loads to be determined.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号