The design of an appropriate analytical method for assessing the quality of pharmaceuticals requires a deep understanding of science, and risk evaluation approaches are appreciated. The current study discusses how a related substance method was developed for Nintedanib esylate. The best possible separation between the critical peak pairs was achieved using an X-Select charged surface hybrid Phenyl Hexyl (150 × 4.6) mm, 3.5 μm column. A mixture of water, acetonitrile, and methanol in mobile phase-A (70:20:10) and mobile phase-B (20:70:10), with 0.1% trifluoroacetic acid and 0.05% formic acid in both eluents. The set flow rate, wavelength, and injection volumes were 1.0 ml/min, 285 nm, and 5 μl, respectively, with gradient elution. The method conditions were validated as per regulatory requirements and United States Pharmacopeia general chapter < 1225 >. The correlation coefficient for all impurities from the linearity experiment was found to be > 0.999. The % relative standard deviation from the precision experiments ranged from 0.4 to 3.6. The mean %recovery from the accuracy study ranged from 92.5 to 106.5. Demonstrated the power of the stability-indicating method through degradation studies; the active drug component is more vulnerable to oxidation than other conditions. Final method conditions were further evaluated using a full-factorial design. The robust method conditions were identified using the graphical optimization from the design space.  相似文献   
2.
This study developed and validated a trace-level quantification inorganic impurities method using reversed-phase HPLC and performed the robustness check using quality-by-design approach by varying the multiple factors simultaneously. This method is economical and simple and exhibits its stability-indicating nature [for the determination of ferrocyanide ([Fe(CN)₆]4–), ferricyanide ([Fe(CN)6]3−), nitrate (NO3), and nitrite (NO2)] in sodium nitroprusside (SNP) drug substance and liquid dosage form. Chromatographic separation was achieved using a USP L43 column (ACE PFP, 150 × 4.6 mm, 3 μm) with a simple isocratic elution. The buffer consists of potassium dihydrogen phosphate (50 mM), tetrabutylammonium hydrogen sulfate (9 mM), and tetrabutylammonium hydroxide (25 mM). The buffer pH was adjusted to 7.2 with tetrabutylammonium hydroxide. The mobile phase was mixed with the buffer and acetonitrile (68:32 v/v). The flow rate was 0.8 mL/min, column temperature was maintained at 30°C, and injection volume was 5.0 μL. The SNP impurities were monitored at 225 nm using a UV detector. Further, the method was validated per the International Council for Harmonisation (ICH) guidelines, and forced degradation studies were carried out under different stress conditions. The detector responses were plotted against concentrations, and correlation was linear (r > 0.999) over the range of 0.8–7.5 μg/mL for ferricyanide; 1.0–37.5 μg/mL for SNP; and 0.2–7.5 μg/mL for ferrocyanide, nitrite, and nitrate. The method repeatability was established for all the impurities with relative standard deviation (%), and the results were found to be less than 2.0.  相似文献   
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号