Zaharescu M. Jitianu A. Brăileanu A. Madarász J. Novák CS. Pokol G. 《Journal of Thermal Analysis and Calorimetry》2003,71(2):421-428
Hybrid materials with different amounts of organics permanently bound on the inorganic network obtained in the TEOS-MTEOS
(tetraethoxysilan-methyltriethoxysilan) system are used for obtaining coatings with different optical and mechanical properties.
To study the thermal stability of the mentioned materials, compositions with different molar ratios of the precursors were
prepared. The influence of the solvent and water amounts on the gelation process was also investigated. The gels obtained
were characterised by IR spectrometry and their decomposition temperatures were determined by DTA/TG. Thermal stability of
the gels is rather influenced by their composition than the conditions of the gelation process.
This revised version was published online in July 2006 with corrections to the Cover Date. 相似文献
2.
J. Somlai B. Kanyár R. Bodnár CS. Németh Z. Lendvai 《Journal of Radioanalytical and Nuclear Chemistry》1996,207(2):437-443
A significant dose contribution on the population could be derived from coal slags used as isolation material. Extremely high natural activities are measured in the coal slag, derived from the region of the settlement Ajka, Hungary. In some buildings monitored, the elevated -doses were nearly 5–10 times higher than the world average ones. The annual average indoor radon concentrations from the slag exceeded 400 Bq/m3 and in some cases up to 1200 Bq/m3. Due to the elevated exposure and the radon concentrations in the dwellings the annual dose was estimated to 8–24 mSv/y more than 5–10 times of the world average one. 相似文献
3.
A rapid and sensitive RP-HPLC method with UV detection at 305 nm for routine quality control of entacapone in tablets was developed. The procedure was validated by specificity, robustness, linearity, accuracy, repeatability and intermediate precision. Experimental design was used during validation to calculate method robustness. The method employs an Ace RP-18 (250 × 4.6 mm i.d., particle size 5 μm), with a mobile phase consisting of water pH 3.0: acetonitrile (65:35, v/v). Entacapone solutions were exposed to direct UV radiation (254 nm), alkaline hydrolysis, acid hydrolysis and effect of oxidation by hydrogen peroxide to evaluate method stability-indication and peak purity tool was utilized to verify the peak purity. The results confirm that the method is highly suitable for its intended purpose. 相似文献
4.
A. GARAY S. DEMETER K. KOVÁCS G. HORVÁTH ÁGNES FALUDI-DÁNIEL 《Photochemistry and photobiology》1972,16(2):139-144
Abstract— Circular dichroism (CD) spectra were studied in System I particles prepared by digitonin fragmentation of chloroplasts of normal maize and carotenoid-deficient mutants. CD bands of pigment molecules were found to be higher in particles than in solutions. This phenomenon was most pronounced for the particles containing the carotenoid composition of normal chloroplast lamellae. The CD signal of chlorophylls bound to particles of carotenoid-deficient chloroplasts was closer to that found in solutions. This indicates that aggregation and/or binding of chlorophylls in carotenoid-deficient mutants may be less extensive than in normal chloroplasts. 相似文献
5.
Gomes P Wingert NR Paim CS Schapoval EE Steppe M 《Journal of AOAC International》2010,93(6):1829-1835
A stability-indicating HPLC assay method was developed for the quantitative determination of duloxetine (DLX) in a pharmaceutical dosage form in the presence of its degradation products, and kinetic determinations were evaluated in acid conditions and UV-C radiation exposure. Chromatographic separation was achieved by use of an ACE C18 column (250 x 4.0 mm id, 5 microm particle size). The mobile phase was prepared by mixing aqueous 50 mM potassium phosphate buffer (pH 6.0 containing 0.3% triethylamine) and acetonitrile (60 + 40, v/v). DLX was rapidly degraded in an acid medium and in the presence of hydrogen peroxide and UV-C radiation; it was more stable in alkaline medium. The described method was linear over a range of 4.0-14.0 microg/mL for determination of DLX (r = 0.9998). The precision was demonstrated by the RSD of intraday (0.79-1.07%) and interday (0.85%) studies. The mean recovery was found to be 100.56%. The acid degradation of DLX in 0.1 M HCI solution showed an apparent zero-order kinetics (k = 0.177 microg/mL/min), and the photodegradation demonstrated an apparent first-order kinetics (k = 0.082 microg/mL/min). The developed method was found to be simple, specific, robust, linear, precise, and accurate for the determination of DLX in enteric-coated pellets. 相似文献
6.
The degradation kinetics of the antibiotic telithromycin using a stability-indicating high-performance liquid chromatography (HPLC) method is demonstrated. The photodegradation is performed by UVC lamp-254 nm (15W), installed in a chamber internally coated with mirrors, where telithromycin solutions prepared from coated tablets are placed in quartz cells. To promote oxidation, the reaction between the telithromycin solution and 3% hydrogen peroxide solution is carried out. The kinetics parameters of order of reaction and the rate constants of the degradation are determined for both conditions. The degradation process of telithromycin can be described by first-order kinetics under both experimental conditions used in this study. The results reveal the photo and oxidation lability of the drug and confirm the reliability of HPLC method for telithromycin in the presence of its degradation products. 相似文献
7.
8.
Facile Synthesis and Structural Characterization by NMR,ESI–MS/MS and DFT Calculations of New (E)‐6‐[2‐Ferrocenylalkylidenehydrazino]nicotinic Hydrazides and Their (E)‐Ferrocenyl‐pyrazolyl‐pyridine Heterocyclic System 下载免费PDF全文
Liliane M. F. Porte Gisele R. Paim Thiago G. Schwanz Alexandre R. Meyer Helio G. Bonacorso Marcos A. P. Martins Nilo Zanatta 《Journal of heterocyclic chemistry》2014,51(5):1333-1339
This paper reports a facile and convenient access by a conventional thermal procedure in ethanol as solvent to a new examples of (E)‐6‐[2‐ferrocenylalkylidenehydrazino]nicotinic hydrazides ( 3 ) (53–72%) from the quimioselective reactions of 6‐hydrazinonicotinc hydrazide ( 1 ) with acylferrocenes ( 2 ), where acyl = formyl and acetyl. Subsequently, cyclocondensation reactions of ferrocenylalkylidene hydrazones ( 3 ) with 4‐R1‐4‐alkoxy‐1,1,1‐trifluoroalk‐3‐en‐2‐ones ( 4 ), where R1 = Me, Ph, 2‐Furyl, to obtain new six heterocyclic derivatives as (E)‐pyrazolyl‐pyridinohydrazones ( 5 ) (58–63%), are also presented. The structures of these new heterocyclic compounds 5 containing an organometallic unit were characterized and studied by NMR, ESI–MS/MS techniques. DFT calculations were also employed to assign the E configuration for compounds 3 and 5 . 相似文献
9.
The validation of a microbiological assay applying the cylinder-plate method to determine the quinolone gemifloxacin mesylate (GFM) content is described. Using a strain of Staphylococcus epidermidis ATCC 12228 as the test organism, the GFM content in tablets at concentrations ranging from 0.5 to 4.5 μg mL−1 could be determined. A standard curve was obtained by plotting three values derived from the diameters of the growth inhibition zone. A prospective validation showed that the method developed is linear (r = 0.9966), precise (repeatability and intermediate precision), accurate (100.63%), specific and robust. GFM solutions (from the drug product) exposed to direct UVA radiation (352 nm), alkaline hydrolysis, acid hydrolysis, thermal stress, hydrogen peroxide causing oxidation, and a synthetic impurity were used to evaluate the specificity of the bioassay. The bioassay and the previously validated high performance liquid chromatographic (HPLC) method were compared using Student's t test, which indicated that there was no statistically significant difference between these two validated methods. These studies demonstrate the validity of the proposed bioassay, which allows reliable quantification of GFM in tablets and can be used as a useful alternative methodology for GFM analysis in stability studies and routine quality control. The GFM reference standard (RS), photodegraded GFM RS, and synthetic impurity samples were also studied in order to determine the preliminary in vitro cytotoxicity to peripheral blood mononuclear cells. The results indicated that the GFM RS and photodegraded GFM RS were potentially more cytotoxic than the synthetic impurity under the conditions of analysis applied. 相似文献
10.
Barth AB de Oliveira GB Malesuik MD Paim CS Volpato NM 《Journal of chromatographic science》2011,49(7):512-518
A stability-indicating liquid chromatography method for the determination of the antifungal agent butenafine hydrochloride (BTF) in a cream was developed and validated using the Plackett-Burman experimental design for robustness evaluation. Also, the drug photodegradation kinetics was determined. The analytical column was operated with acetonitrile, methanol and a solution of triethylamine 0.3% adjusted to pH 4.0 (6:3:1) at a flow rate of 1 mL/min and detection at 283 nm. BTF extraction from the cream was done with n-butyl alcohol and methanol in ultrasonic bath. The performed degradation conditions were: acid and basic media with HCl 1M and NaOH 1M, respectively, oxidation with H(2)O(2) 10%, and the exposure to UV-C light. No interference in the BTF elution was verified. Linearity was assessed (r(2) = 0.9999) and ANOVA showed non-significative linearity deviation (p > 0.05). Adequate results were obtained for repeatability, intra-day precision, and accuracy. Critical factors were selected to examine the method robustness with the two-level Plackett-Burman experimental design and no significant factors were detected (p > 0.05). The BTF photodegradation kinetics was determined for the standard and for the cream, both in methanolic solution, under UV light at 254 nm. The degradation process can be described by first-order kinetics in both cases. 相似文献