首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   9篇
  免费   0篇
化学   3篇
物理学   6篇
  2009年   1篇
  2006年   2篇
  2005年   1篇
  2002年   1篇
  2001年   1篇
  1999年   1篇
  1993年   1篇
  1989年   1篇
排序方式: 共有9条查询结果,搜索用时 218 毫秒
1
1.
2.
Characterization of the tissue light penetration in prostate photodynamic therapy (PDT) is important to plan the arrangement and weighting of light sources so that sufficient light fluence is delivered to the treatment volume. The optical properties (absorption [mu(a)], transport scattering [mu(s)'] and effective attenuation [mu(eff)] coefficients) of 13 patients with locally recurrent prostate cancer were measured in situ using interstitial isotropic detectors. Measurements were made at 732 nm before and after motexafin lutetium (MLu)-mediated PDT in four quadrants. Optical properties were derived by applying the diffusion theory to the fluence rates measured at several distances (0.5-5 cm) from a point source. mu(a) and mu(s)' varied between 0.07 and 1.62 cm(-1) (mean 0.37 +/- 0.24 cm(-1)) and 1.1 and 44 cm(-1) (mean 14 +/- 11 cm(-1)), respectively. mu(a) was proportional to the concentration of MLu measured by an ex vivo fluorescence assay. We have observed, on average, a reduction of the MLu concentration after PDT, presumably due to the PDT consumption of MLu. mu(eff) varied between 0.91 and 6.7 cm(-1) (mean 2.9 +/- 0.7 cm(-1)), corresponding to an optical penetration depth (delta = 1/micro(eff)) of 0.1-1.1 cm (mean 0.4 +/- 0.1 cm). The mean penetration depth at 732 nm in human prostate is at least two times smaller than that found in normal canine prostates, which can be explained by a four times increase of the mean value of mu(s)' in human prostates. The mean light fluence rate per unit source strength at 0.5 cm from a point source was 1.5 +/- 1.1 cm(-2), excluding situations when bleeding occurs. The total number of measurements was N = 121 for all mean quantities listed above. This study showed significant inter- and intraprostatic differences in the optical properties, suggesting that a real-time dosimetry measurement and feedback system for monitoring light fluences during treatment should be considered for future PDT studies.  相似文献   
3.
PK Srivastava  DK Rai  SB Rai 《Pramana》2001,56(6):823-830
Overtone spectrum of o, m and p-nitrobenzaldehydes and p-chlorobenzaldehyde has been studied in 2000–12000 cm−1 region. Vibrational frequencies and anharmonicity constants for aryl as well as alkyl CH stretch vibrations have been determined. We have also determined the internuclear distances for the aryl CH bond in the different molecules. The small variation observed in these distances is an indication of the substitution effect. It is observed that in the case of p-disubstituted benzens, the shift in aryl CH bond is proportional to sum of the Hammet σ of the substituents. However in the case of o-disubstituted benzenes it is only 80% of the para-substituted shift.  相似文献   
4.
Photodynamic therapy (PDT) requires oxygen to cause cellular and vascular tumor damage. Tissue oxygen concentration, in turn, is influenced by blood flow and blood oxygenation. Real-time clinical measurement of these hemodynamic quantities, however, is rare. This paper reports the development and application of a probe, combining diffuse reflectance spectroscopy (DRS) for measurement of tumor blood oxygenation and diffuse correlation spectroscopy (DCS) for measurement of tumor blood flow. The instrument was adapted for clinical use during interstitial prostate PDT. Three patients with locally recurrent prostate cancer received 2 mg/ kg motexafin lutetium (MLu) 3 h before illumination and a total light dose of 100 J/cm(2) at 150 mW/cm. Prostrate blood oxygen saturation (StO2) decreased only slightly (approximately 3%) after treatment. On the other hand, prostate blood flow and total hemoglobin concentration over the course of PDT decreased by 50% and 15%, respectively, suggesting MLu-mediated PDT has an anti-vascular effect. While it is certainly impossible to draw definite conclusions from measurements of only three patients, the observed differences in tumor blood flow and blood oxygenation responses during PDT can, in principle, be used to choose among tissue oxygen consumption models and therefore emphasize the potential clinical value for simultaneous monitoring of both parameters.  相似文献   
5.
SB Patel 《Pramana》1999,53(3):405-405
With the advent of medium and large gamma detector arrays, it is now possible to look at nuclear structure at high rotational forces. The role of pairing correlations and their eventual breakdown, along with the shell effects have showed us the interesting physics for nuclei at high spins — superdeformation, shape co-existence, yrast traps, alignments and their dramatic effects on nuclear structure and so on. Nuclear structure studies have recently become even more exciting, due to efforts and possibilities to reach nuclei far off from the stability valley. Coupling of gamma ray arrays with ‘filters’, like neutron wall, charged particle detector array, gamma ray total energy and multiplicity castles, conversion electron spectrometers etc gives a great handle to study nuclei produced online with ‘low’ cross-sections. Recently we studied, nuclei in mass region 80 using an array of 8 germanium detectors in conjunction with the recoil mass analyser, HIRA at the Nuclear Science Centre and, most unexpectedly came across the phenomenon of identical bands, with two quasi-particle difference. The discovery of magnetic rotation is another highlight. Our study of light In nucleus, 107In brought us face to face with the ‘dipole’ bands. I plan to discuss some of these aspects. There is also an immensely important development — that of the ‘radioactive ion beams’. The availability of RIB, will probably very dramatically influence our ‘conventional’ concept of nuclear structure. The exotic shapes of these exotic nuclei and some of their expected properties will also be touched upon.  相似文献   
6.
Rare earth element substituted bismuth ferrites (BiFeO3) are of enormous importance as magnetoelectric materials. The polycrystalline samples of Bi x La1−x FeO3 (x=0, 0.2, 0.4, 0.6, 0.8) were prepared by solid-state reaction using standard ceramic method. The single-phase formation of these compounds was confirmed by X-ray diffraction (XRD) studies. The samples with x=0, 0.2, 0.4, 0.6 are found to be orthorhombic while the sample with x=0.8 is triclinic. The dielectric constant (ε′) and dissipation factor (tan δ) were measured in the frequency range 100 Hz to 1 MHz at room temperature and as a function of temperature at certain fixed frequencies (1 kHz, 10 kHz, 100 kHz, 1 MHz). All the samples showed dielectric dispersion. The dielectric constant with temperature shows a broad peak; the peak temperature shifts with frequency which reflects the relaxor-type behavior. The peak above 600 K in the measured temperature range corresponds to antiferromagnetic ordering temperature (Néel temperature). The broadness of the peak changes with composition. The ac conductivity as well as ε′ are found to be maximum for the sample x=0.2 at room temperature.  相似文献   
7.
The in vivo fluorescence emission from human prostates was measured before and after motexafin lutetium (MLu)-mediated photodynamic therapy (PDT). A single side-firing optical fiber was used for both the delivery of 465 nm light-emitting diode excitation light and the collection of emitted fluorescence. It was placed interstitially within the prostate via a closed transparent plastic catheter. Fitting of the collected fluorescence emission spectra using the known fluorescence spectrum of 1 mg/kg MLu in an intralipid phantom yields a quantitative measure of the local MLu concentration. We found that an additional correction factor is needed to account for the reduction of the MLu fluorescence intensity measured in vivo due to strong optical absorption in the prostate. We have adopted an empirical correction formula given by C = (3.1 cm(-1)/micro's) exp (microeff x 0.97 cm), which ranges from approximately 3 to 16, with a mean of 9.3 +/-4.8. Using a computer-controlled step motor to move the probe incrementally along parallel tracks within the prostate we can determine one-dimensional profiles of the MLu concentration. The absolute MLu concentration and the shape of its distribution are confirmed by ex vivo assay and by diffuse absorption measurements, respectively. We find significant heterogeneity in photosensitizer concentration within and among five patients. These variations occur over large enough spatial scales compared with the sampling volume of the fluorescence emission that mapping the distribution in three dimensions is possible.  相似文献   
8.

Background  

Neural differentiation of embryonic stem (ES) cells is usually achieved by induction of ectoderm in embryoid bodies followed by the enrichment of neuronal progenitors using a variety of factors. Obtaining reproducible percentages of neural cells is difficult and the methods are time consuming.  相似文献   
9.
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号