首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   41篇
  免费   0篇
化学   19篇
力学   1篇
数学   1篇
物理学   20篇
  2017年   1篇
  2016年   1篇
  2013年   3篇
  2011年   3篇
  2008年   2篇
  2007年   3篇
  2006年   2篇
  2004年   2篇
  2003年   1篇
  1999年   6篇
  1996年   1篇
  1995年   2篇
  1994年   2篇
  1993年   4篇
  1992年   2篇
  1991年   1篇
  1990年   1篇
  1988年   2篇
  1986年   2篇
排序方式: 共有41条查询结果,搜索用时 250 毫秒
1.
2.
3.
4.
5.
The interaction between antibody and antigen is characterised by relatively high affinity and specificity, making this type of reaction a prime candidate for use as an analytical tool. The interaction may be combined with biosensors in the production of immunosensors for environmental monitoring. Polyclonal and monoclonal antibodies have had a significant impact in analytical detection systems over the past few decades with antibody fragments becoming important in recent years. Production of antibodies to small haptens requires the initial conjugation of hapten to a larger carrier molecule. Once hapten-carrier conjugates have been produced, polyclonal, monoclonal and various antibody fragments may be produced by differing protocols. A critical step in the production of antibody fragments is the development of efficient screening procedures to identify suitable antibody-producing clones and this has been reviewed in this article. Various antibody types may then be used in the generation of immunosensors for the monitoring of environmental pollutants. The selection of the appropriate sensor technology applicable for the determination of an antibody-antigen interaction is of prime importance for immunosensor development. One example of such an application is surface plasmon resonance-based biosensors, as they provide real-time analysis of interactions between the antibody and antigen of interest.  相似文献   
6.
A sensor for the amperometric detection of aqueous ammonia was fabricated using the inkjet printing of dodecylbenzene sulfonate (DBSA)-doped polyaniline nanoparticles (nanoPANI) onto a screen-printed carbon paste electrode. The combination of the environmentally inert, aqueous nanoparticle dispersion with the inkjet printing technique allowed the rapid fabrication of sensors based on polyaniline that was not easily achievable in the past due to the lack of processability of bulk forms of the conducting polymer. The resulting modified electrode was characterised with respect to its operating pH and number of print layers and was found to perform optimally at near neutral pH with four nanoPANI inkjet-printed layers. The sensor was tested in a flow injection system for its response to aqueous ammonia using amperometric detection at -0.3 V vs. Ag/AgCl pseudo-reference and was found to have reproducibility to injections of ammonia of below 5% RSD and good sensitivity with an experimental detection limit of 20 microM and a theoretical detection limit of 3.17 microM (0.54 ppm). The sensor was also tested for its day-to-day stability and its response towards a range of interferents common to refrigerant waste waters. This system allows the rapid production of an ultra-low-cost, solid state, polyaniline-based aqueous ammonia sensor.  相似文献   
7.
Fast atom bombardment, combined with high-energy collision-induced tandem mass spectrometry, has been used to investigate gas-phase metal-ion interactions with captopril, enalaprilat and lisinopril, all angiotensin-converting enzyme inhibitors.Suggestions for the location of metal-binding sites are presented. For captopril, metal binding occurs most likely at both the sulphur and the nitrogen atom. For enalaprilat and lisinopril, binding preferably occurs at the amine nitrogen. Copyright 1999 John Wiley & Sons, Ltd.  相似文献   
8.
Not only are sensors a revolution in analysis; they themselves are also experiencing a revolution brought about by parallel developments in sensor fabrication techniques and materials, polymer chemistry, signal processing methodologies, the increased use of biomolecular processes as a means of analyte detection, and the coupling of sensors to other techniques such as flow injection analysis. Many of these developments have been incorporated into the present study, which we are undertaking in the development of our immunosensor technology. The system described here utilises screen-printed electrodes which are low-cost, disposable devices that are simple to fabricate. Incorporated into our sensor is the electroactive polymer, polyaniline, which brings about mediatorless redox coupling between the electrode and biomolecular components attached to the polymer surface. This system also utilises enzyme-labelled antibodies as the biomolecular recognition component for the analysis of the test analyte, biotin. The system has also been integrated into a flow injection system. This has led to the monitoring of real-time antibody-antigen interactions using electrochemical methods and foreshadows the development of single-step immunosensors.  相似文献   
9.
With lower limits of detection and increased stability constantly being demanded of biosensor devices, characterisation of the constituent layers that make up the sensor has become unavoidable, since this is inextricably linked with its performance. This work describe the optimisation and characterisation of two aspects of sensor performance: a conductive polymer layer (polyaniline) and the immobilised protein layer. The influence of the thickness of polyaniline films deposited electrochemically onto screen-printed electrode surfaces is described in this work in terms of its influence on a variety of amperometric sensor performance characteristics: time to reach steady state, charging current, catalytic current, background current and signal/background ratios. The influence of polymer film thickness on the conductivity and morphology of finished films is also presented.

An electrostatic method of protein immobilisation is used in this work and scanning electron microscopy in conjunction with gold-labelled antibodies and back-scattered electron detection has enabled the direct visualisation of individual groups of proteins on the sensor surface. Such information can provide an insight into the performance of sensors under influence of increasing protein concentrations.  相似文献   

10.
A biosensor with improved performance was developed through the immobilization of horseradish peroxidase (HRP) onto electropolymerized polyaniline (PANI) films doped with carbon nanotubes (CNTs). The effects of electropolymerization cycle and CNT concentration on the response of the biosensor toward H2O2 were investigated. It was found that the application of CNTs in the biosensor system could increase the amount and stability of the immobilized enzyme, and greatly enhanced the biosensor response. Compared with the biosensor without CNTs, the proposed biosensor exhibited enhanced stability and approximately eight-fold sensitivity. A linear range from 0.2 to 19 μM for the detection of H2O2 was observed for the proposed biosensor, with a detection limit of 68 nM at a signal-to-noise ratio of 3 and a response time of less than 5 s.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号