首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   22篇
  免费   0篇
化学   22篇
  2020年   1篇
  2019年   1篇
  2018年   1篇
  2017年   1篇
  2016年   5篇
  2015年   1篇
  2013年   2篇
  2011年   2篇
  2010年   1篇
  2009年   1篇
  2008年   1篇
  2007年   1篇
  2005年   1篇
  2003年   1篇
  2002年   2篇
排序方式: 共有22条查询结果,搜索用时 140 毫秒
1.
A novel method for the continuous monitoring of thermooxidative degradation products of polystyrene by membrane extraction with sorbent interface (MESI) and gas chromatography (GC) is developed. The results are compared with solid-phase microextraction-GC, which can extract gases, vapors, and aerosols. The volatile and semivolatile degradation products are identified by mass spectrometry. The membrane used in the MESI-GC analysis shows a high permeation for volatile aromatic hydrocarbons; a low permeation for corresponding volatile aldehydes; and no permeation for less volatile alcohols, acids, and degradation products with a high molecular weight, thus reducing significantly the number of compounds detected from MESI-GC. Sensitivity of the method depends on the time of trapping, which is limited by the breakthrough of the trap. By heating the trap at fixed intervals of time, consecutive gas chromatograms are obtained.  相似文献   
2.
Three new dispersive liquid–liquid microextraction (DLLME) methods, air-assisted (AA-DLLME), vortex-assisted (VA-DLLME) and ultrasound-assisted (UA-DLLME), were compared from the point of view of their analytical application for preconcentration of trace amounts of benzene, toluene, ethylbenzene and xylene isomers (BTEX) in water samples. In all of these methods, no dispersive solvent is required and dispersion of extractant is carried out by air bubbles, vortex and ultrasound for AA-DLLEM, VA-DLLME, and UA-DLLME, respectively. Advantages and disadvantages of these three liquid phase microextraction methods and their capability in dispersion of a similar extractant phase in sample solutions were comprehensively compared. All other extraction parameters, which have an influence on the microextraction, were also investigated and optimized. Under optimized conditions, analytical figures of merit for the three techniques were determined and compared. It was found that the limit of detection of the three methods is almost the same, while AA-DLLME has a wider linear dynamic range and the shortest analysis time. Enrichment factors of 182, 45 and 245 were achieved for AA-DLLEM, VA-DLLME, and UA-DLLME, respectively.  相似文献   
3.
The use of a functionalized latex nanoparticle coating as a new sorbent phase for solid-phase microextraction (SPME) was examined. By means of electrostatic absorption onto ionized silanol groups, a fused-silica rod was coated with polymeric nanoparticles functionalized with quaternary ammonium groups. Optimum conditions for the preparation of the coated fibre are presented. The fibre was used for the extraction of a mixture of seven anions from water samples which are analysed by coupling the SPME fibre to an ion chromatographic system via a special interface. The results obtained proved the suitability of this novel coating as a new SPME fibre. A linear calibration for the target analytes was achieved over the concentration range from 5 μg L−1 to 5 mg L−1 (r2 > 0.988), while limits of detection for these ions were all below 3.7 μg L−1 (S/N = 3). The reproducibility of a single fibre (n = 4) under similar conditions was between 7 and 12%, while the fibre to fibre reproducibility (n = 5) was between 8.9 and 14%.  相似文献   
4.
5.
A novel carbon paste electrode modified with ZrO2 nanoparticles and an ionic liquid (n-hexyl-3- methylimidazolium hexafluorophosphate) was fabricated. The electrochemical study of the modified electrode, as well as its efficiency for simultaneous voltammetric oxidation of dopamine and uric acid is described. The electrode was also employed to study the electrochemical oxidation of dopamine and uric acid, using cyclic voltammetry, chronoamperometry and square wave voltammetry as diagnostic techniques. Square wave voltammetry exhibits linear dynamic range from 1.0 × 10?6 to 9.0 × 10?4 M for dopamine. Also, square wave voltammetry exhibits linear dynamic range from 9.0 × 10?6–1.0 × 10?3 M for uric acid. The modified electrode displayed strong function for resolving the overlapping voltammetric responses of dopamine and uric acid into two well-defined voltammetric peaks. In the mixture containing dopamine and uric acid, the two compounds can be well separated from each other with potential difference of 155 mV, which is large enough to determine dopamine and uric acid individually and simultaneously. Finally, the modified electrode was used for determination of dopamine and uric acid in real samples.  相似文献   
6.
Kaykhaii M  Nazari S  Chamsaz M 《Talanta》2005,65(1):223-228
The possibility of applying headspace microextraction into a single drop for the determination of amines in aqueous solutions is demonstrated. A 1 μl drop of benzyl alcohol containing 2-butanone as an internal standard was suspended from the tip of a micro syringe needle over the headspace of stirred sample solutions for extraction. The drop was then injected directly into a GC. The total chromatographic determination was less than 10 min. Optimization of experimental conditions (sampling time, sampling temperature, stirring rate, ionic strength of the solution, concentration of reagents, time of extraction and organic drop volume) with respect to the extraction efficiency were investigated and the linear range and the precision were also examined. Calibration curves yielded good linearity and concentrations down to 2.5 ng ml−1 were detectable with R.S.D. values ranging from 6.0 to 12.0%. Finally, the method was successfully applied to the extraction and determination of amines in tap and river water samples. This system represents an inexpensive, fast, simple and precise sample cleanup and preconcentration method for the determination of volatile organic compounds at trace levels.  相似文献   
7.
8.
Microchimica Acta - We report on a rapid and effective method for the determination of methylcyclopentadienyl-manganese tricarbonyl (MMT) in water and gasoline samples. It is based on single drop...  相似文献   
9.
This work reports the preparation of molecularly imprinted polymer particles for selective extraction and determination of iron ions from aqueous media. The polymer particles were synthesized from Fe(NO3)3, morin, 4-vinylpyridine, ethyleneglycoldimethacrylate, and 2,2′-azobisisobutyronitrile and characterized by IR and DSC both prior to and after removing the Fe-morin complex by leaching with HCl. The effect of different parameters, such as pH, adsorption and desorption time, type and minimum amount of eluent for removing the complex from polymer was evaluated and optimized. The proposed method is characterized by the detection limit of 3.1 µg l?1 anddynamic linear range of 25 to 200 µg l?1, with the relative standard deviation less than 8.8%. The method was applied to the recovery and determination of iron ions in a few real samples.  相似文献   
10.
By synthesizing a molecular imprinted polymer as an efficient adsorbent, ciprofloxacin was micro‐extracted from seawater, human blood plasma and tablet samples by pipette‐tip micro solid phase extraction and determined spectrophotometrically. Response surface methodology was applied with central composite design to build a model based on factors affecting on microextraction of ciprofloxacin; including volume of eluent solvent, number of extraction cycles, number of elution cycles, and pH of sample. Other factors that affect extraction efficiency, such as type of eluent solvent, volume of sample, type, and amount of salt were optimized with one‐variable‐at‐a‐time method. Under optimum extraction condition, pH of sample solution was 7.0, volume of eluent solvent (methanol) was 200 µL, volume of sample solution was 10 mL, and the number of extraction and elution cycles was five and seven, respectively, amount of Na2SO4 (as salt) and MIP (as sorbent) were optimized at 150 and 2 mg, respectively. The linear range of the suggested method under optimum extraction factors was 5–150 µg/L with a limit of detection of 1.50 µg/L for the analyte. Reproducibility of the method (as relative standard deviation) was better than 7%.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号