首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   40篇
  免费   0篇
化学   40篇
  2017年   2篇
  2016年   4篇
  2015年   4篇
  2013年   1篇
  2012年   1篇
  2011年   1篇
  2009年   2篇
  2008年   3篇
  2007年   2篇
  2006年   3篇
  2005年   2篇
  2004年   3篇
  2003年   5篇
  2002年   4篇
  2001年   3篇
排序方式: 共有40条查询结果,搜索用时 203 毫秒
1.
Lu S  Wu K  Dang X  Hu S 《Talanta》2004,63(3):653-657
Simple and sensitive electrochemical method for the determination of metronidazole, based on a nanostructured film coated glassy carbon electrode (GCE), is described. Multi-walled carbon nanotubes (MWNT) was dispersed into water in the presence of a hydrophobic surfactant to give very stable and homogeneous MWNT suspension, and a MWNT-film coated GCE was achieved via evaporating solvent. Metronidazole yields a well-defined reduction peak whose potential is −0.71 V at the MWNT-film coated GCE in pH 9.0 Britton-Robinson buffer. Compared with bare GCE, the MWNT-film modified GCE significantly enhances the reduction peak current of metronidazole. All the experimental parameters were optimized for the determination of metronidazole. The detection limit is 6×10−9 mol/l at 2 min accumulation. This method has been successfully used to determine metronidazole in the drugs. Furthermore, results obtained by the proposed method have been compared with spectrophotometric method.  相似文献   
2.
Hu C  Wu K  Dai X  Hu S 《Talanta》2003,60(1):17-24
A simple and effective chemically modified carbon paste electrode (CMCPE) for the simultaneous determination of lead(II) and cadmium(II) was developed in this work. The electrode was prepared by the addition of diacetyldioxime into a carbon paste mixture. Pb2+ and Cd2+ were preconcentrated on the surface of the modified electrode by complexing with diacetyldioxime and reduced at a negative potential (−1.10 V). Then the reduced products were oxidized by differential pulse stripping. The fact that two stripping peaks appeared on the voltammograms at the potentials of −0.65 V (Cd2+) and −0.91 V (Pb2+) demonstrates the possibility of simultaneous determination of Pb2+ and Cd2+. Under the optimized working conditions, calibration graphs were linear in the concentration ranges of 1.0×10−7-1.5×10−5 mol l−1 (Pb2+) and 2.5×10−7-2.5×10−5 mol l−1 (Cd2+), respectively. For 5 min preconcentration, detection limits of 1×10−8 mol l−1 (Pb2+) and 4×10−8 mol l−1 (Cd2+) were obtained at the signal noise ratio (SNR) of 3. To evaluate the reproducibility of the newly developed electrode, the measurements of 5×10−7 mol l−1 Pb2+ and Cd2+ were parallel carried out for six times at different electrodes and the relative standard deviations were 2.9% (Pb2+) and 3.2% (Cd2+), respectively. Interferences by some metals were investigated. Only Ni2+ and Hg2+ apparently affected the peak currents of Pb2+ and Cd2+. The diacetyldioxime modified carbon paste electrode was applied to the determination of Pb2+ and Cd2+ in water samples. The results indicate that this electrode is sensitive and effective for the simultaneous determination of Pb2+ and Cd2+.  相似文献   
3.
Adsorption stripping voltammetry, a very sensitive electroanalytical method, was employed to determine reserpine, a kind of anti-hypertensive drug. In 0.1M phosphate buffer with a pH of 6.0, reserpine was accumulated at a multi-wall carbon nanotubes (MWNT)-modified glassy carbon electrode (GCE) surface under the condition of open-circuit. In the following anodic sweep from 0.20 to 1.00V, reserpine, adsorbed at the MWNT-modified GCE surface, was oxidized and yielded a sensitive oxidation peak at 0.64V. Due to its unique structure and extraordinary properties, MWNT shows a ten times higher accumulation efficiency toward reserpine, compared with a bare GCE. Hence, the amount of reserpine at the MWNT-modified GCE surface increases significantly, and finally the oxidation peak current improves greatly. The experimental conditions, such as supporting electrolyte, pH value, the amount of MWNT-DHP suspension, accumulation time and scan rate, were optimized for the measurement of reserpine, and a sensitive electroanalytical method was proposed for reserpine determination. The oxidation peak current varies linearly with the concentration of reserpine over the range of 2×10–8 to 1×10–5M, and the detection limit is 7.5×10–9M after 4min open-circuit accumulation. The relative standard deviation at 1×10–6M reserpine was about 4.7% (n=7), indicating excellent reproducibility. This new method was successfully demonstrated with reserpine injections and tablets.  相似文献   
4.
Different-shaped aluminas were readily prepared via hydrothermal reaction. It was found that the morphology and the electrochemical sensing properties of alumina were heavily dependent on the reaction time. When extending the reaction time from 6 h to 24 h, the obtained alumina samples changed from amorphous bumps to regular microfibers in diameter of 200 nm, as confirmed by scanning electron microscopy. Transmission electron microscopy observation revealed that longer reaction time was beneficial for the formation of porous and uniform fiber-like structures. Electrochemical tests proved that alumina microfibers were more active for the oxidation of amaranth and exhibited much higher enhancement effect, compared with alumina bumps. On the surface of alumina microfibers, the oxidation peak currents of amaranth increased remarkably. The influences of pH value, amount of alumina microfibers, and accumulation time on the signal enhancement of amaranth were discussed. As a result, a novel electrochemical method was developed for the detection of amaranth. The linear range was from 1 to 150 nM, and the detection limit was 0.75 nM after 1-min accumulation. The analytical application in drink samples was investigated, and the results consisted with the values that obtained by high-performance liquid chromatography.  相似文献   
5.
6.
Gold nanorods (AuNRs) integrated with ZnCdHgSe near-infrared quantum dots (AuNRs-ZnCdHgSe QDs) were successfully synthesized and characterized by transmission electron microscope, X-ray photoelectron spectroscopy, and X-ray diffraction. A glassy carbon electrode was decorated with the aforementioned AuNRs-ZnCdHgSe QDs nanocomposite, which provides a biocompatible interface for the subsequent immobilization of prostate specific antibody (anti-PSA). After being successively treated with glutaraldehyde vapor and bovine serum albumin solution, a photoelectrochemical immunosensing platform based on anti-PSA/AuNRs-ZnCdHgSe QDs/GCE was established. The photocurrent response of ZnCdHgSe QDs was tremendously improved by AuNRs due to the effect of resonance energy transfer which can be deduced from the dependence of the enhanced efficiency on the AuNRs with different length-to-diameter ratios and spectral absorption characteristics. A maximum photocurrent was obtained when the absorption spectrum of AuNRs matched well with the emission spectrum of ZnCdHgSe QDs. A photoelectrochemical immunosensor for prostate specific antigen (PSA) was achieved by monitoring the photocurrent variation. The photocurrent variation before and after being interacted with PSA solution exhibits a good linear relationship with the logarithm of its concentration (logcPSA) in the range from 1.0 pg mL−1 to 50.0 ng mL−1. The detection limit of this photoelectrochemical immunosensor is able to reach 0.1 pg mL−1 (S/N = 3). Determining PSA in clinical human serum was also demonstrated by using the developed anti-PSA(BSA)/AuNRs-ZnCdHgSe QDs/GCE electrode. The results were comparable with those obtained from an enzyme-linked immunosorbent assay method.  相似文献   
7.
A nanostructured film electrode, a multi-wall carbon nanotubes (MWNT)-modified glassy carbon electrode (GCE), is described for the simultaneous determination of guanine and adenine. The properties of the MWNT-modified GCE were investigated by scanning electron microscopy (SEM) and cyclic voltammetry. The oxidation peak currents of guanine and adenine increased significantly at the MWNT-modified GCE in contrast to those at the bare GCE. The experimental parameters were optimized and a direct electrochemical method for the simultaneous determination of guanine and adenine was proposed. Using the MWNT-modified GCE, a sensitive and direct electrochemical technique for the measurement of native DNA was also developed, and the value of (G+C)/(A+T) of HCl-digested DNA was detected.  相似文献   
8.
 Multi-wall carbon nanotubes (MWNT) have been dispersed into water with the emulsification of oil of turpentine and emulsifier OP TX-100. An MWNT-modified glassy carbon electrode (GCE) has been achieved through solvent evaporation of MWNT- dispersion. In pH 2.0 phosphate buffer, MWNT- modified GCE has an obvious catalytic effect on the oxidation of estradiol, estrone and estriol. The oxidation peak current of these estrogens at the modified electrode increases significantly in contrast with that at the bare GCE. The experimental conditions which heavily affect the oxidation peak current of estradiol, such as the solution pH, the amount of MWNT, the scan rate, the adsorption potential and adsorption time, were optimized. The peak current is linear to the concentration in the range of 2.5 × 10−7 to 5 × 10−5 mol L−1 estradiol. The detection limit is 1 × 10−8 mol L−1 after 3 min open-circuit adsorption. The relative standard deviation (RSD) of six measurements using an electrode is 3.2% for 1 × 10−5 mol L−1 estradiol. The effect of interferences of other organic compounds on the determination of estradiol was examined. Author for correspondence: Department of Chemistry, Wuhan University, Wuhan 430072, P.R. China. E-mail: sshu@whu.edu.cn Received June 19, 2002; accepted January 4, 2003 Published online April 11, 2003  相似文献   
9.
A method is described for the determination of estrogens (estradiol, estrone and estriol) by stripping voltammetry. These estrogens yield one well-defined oxidation peak at the Nafion-modified glassy carbon electrode in the presence of cetyltrimethylammonium bromide (CTAB). The peak current is proportional to the concentration of estradiol in the range from 2.5×10−8 to 1.5×10−6 mol/l, and the detection limit is 1×10−9 mol/l after accumulation of 6 min. The total amounts of estrogens in the blood serums were determined using the voltammetric method, and the average recovery was 106.04%. The mechanism of the oxidation of estradiol was investigated by electrochemical techniques and UV spectra.  相似文献   
10.
In this paper, a new voltammetric method for the determination of phenol is described. In pH 8.00 phosphate buffer and in the presence of long-chain cationic surfactant—cetyltrimethylammonium bromide—phenol has a very sensitive oxidation peak at 0.47 V (vs. SCE) on the Nafion-modified glassy carbon electrode (GCE). The experimental parameters, such as supporting electrolyte and pH values, amounts of Nafion, varieties and concentration of surfactants, accumulation potential and time, as well as scan rate were optimized. The peak current is linear with the concentration of phenol in the range from 8×10−9 to 1×10−5 M, and the detection limit is 1×10−9 M after being accumulated at −0.50 V (vs. SCE) for 3 min. Trace levels of phenol in water samples were determined by using this voltammetric method, the average recovery was calculated to be 99.56%.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号