首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   29篇
  免费   0篇
化学   14篇
数学   3篇
物理学   12篇
  2013年   1篇
  2012年   4篇
  2011年   2篇
  2008年   1篇
  2007年   2篇
  2006年   3篇
  2005年   4篇
  2004年   2篇
  2003年   1篇
  2001年   3篇
  1999年   2篇
  1997年   1篇
  1978年   1篇
  1974年   1篇
  1973年   1篇
排序方式: 共有29条查询结果,搜索用时 718 毫秒
1.
Gélat PN  Zeqiri B  Hodnett M 《Ultrasonics》2005,43(5):321-330
This paper describes a theoretical study of the way in which a circular aperture placed in front of a plane-piston modifies the ultrasonic field it generates. Specifically, the radiated acoustic power transmitted by the aperture and the radiation force experienced by an absorbing target placed in the transmitted beam, are evaluated at a distance from the exit-side of the aperture. The calculations used a finite element (FE) method, in conjunction with a surface Helmholtz integral formulation to solve the fluid/structure interaction problem. The PAFEC (Program for Automatic Finite Element Computation) vibroacoustics software was used for the FE calculations and the implementation of the surface Helmholtz integral formulation method. Acoustic pressures and particle velocities were computed at required points, whilst accounting for the presence of the aperture in the medium, together with its dynamic properties when subjected to an incident sound field. This enabled the calculation of the radiation force on the absorber and its variation with the applied aperture diameter was investigated. As part of the validation process for the new FE aperture model, the ratio of radiation force to radiated acoustic power obtained using the FE method in the unapertured case, through the use of the Rayleigh integral, yielded good agreement with results obtained through an analytical solution. The study has been carried out to provide a better understanding of the factors affecting the measurement uncertainty for the aperture method of determining the effective radiating area (A(ER)) of physiotherapy ultrasound treatment heads.  相似文献   
2.
This paper describes the application of a novel broadband acoustic sensor to evaluating the acoustic emissions from cavitation produced by a typical commercial 20 kHz sonochemical horn processor. Investigations of the reproducibility of the processor, and of the variation in cavitation emissions as a function of output setting and sensor location are described, and resulting trends discussed in terms of the broadband integrated power in the megahertz frequency range. Companion studies with a conventional membrane hydrophone have illustrated for the first time that cavitation emissions produced by a sonochemical horn processor can extend to frequencies beyond 20 MHz, and the sensor shows that significant nonlinearity can be seen in measured cavitation activity with increasing nominal output power.  相似文献   
3.
4.
Evidence is presented for the secondary nucleation of beta-L-glutamic acid on the surface of the alpha-polymorph, using a combination of Scanning Electron Microscopy and Raman spectroscopy.  相似文献   
5.
Natural convection between infinitely long, horizontal, heated, concentric circular cylinders is considered. It is assumed that the temperature difference between the cylinders is small and also that the radius of the inner cylinder is small. It is shown that the problem is mainly conduction dominated provided thatR, the ratio of the radius of the outer cylinder to the radius of the inner cylinder, is not too large. The criterion derived for a conduction dominated problem is a relation betweenR and the Grashof number.
Zusammenfassung Die freie Konvektion zwischen zwei unendlichen, horizontalen, geheizten, konzentrischen Zylindern wird untersucht. Der Temperaturunterschied zwischen den Zylindern sowohl wie der Radius des inneren Zylinders, wird klein angenommen. Es wird gezeigt, dass das Problem vom Wärmedurchgang beherrscht ist, fallsR, das Verhältnis zwischen dem Radius des äusseren und inneren Zylinders, nicht zu gross ist. Das abgeleitete Kriterium für diesen Fall ist eine Beziehung zwischenR und der Grashof-Zahl.
  相似文献   
6.
NG Kelkar  BK Jain 《Pramana》2001,57(2-3):389-397
We report on a study of the proton induced hyperon production reactions. We discuss the theoretical efforts made towards understanding the existing data and the uncertainties involved in the calculations. Our recent calculations of the missing mass spectra for the ppK + Λp reaction which involve a proper coupled channel treatment of the final state Λp interaction are presented. Significant differences in the results using different models of the hyperon-nucleon interaction are found.  相似文献   
7.
We have investigated the fast ethylamine gas sensing of 2-chloro-3,5-dinitrobenzotrifluoride(CDBF) loaded poly(acrylonitrile) nanofiber based on an intermolecular charge-transfer complexation.Reversible response and recovery were achieved using alternating gas exposure.This system shows a fast ethylamine gas sensing within 0.4 s.  相似文献   
8.
This paper uses a partial differential equation which occurs in a reduced model of large scale circulation in an ocean basin as an educational vehicle through which to demonstrate the usefulness of a set of mathematical techniques in analysing the equation. A parameter occurring in the equation does in reality vary from very small through intermediate to very large values. Therefore separate solutions are required for (a) very small, (b) very large and (c) intermediate values of the parameter. This allows for the demonstration of how when the parameter is very small the method of characteristics and the singular perturbation method are useful. When the parameter is very large the regular perturbation method is useful. At intermediate values of the parameter numerical methods must be used and in this case it is a helpful check to have available the asymptotic results for both small and large values of the parameter.  相似文献   
9.
This paper describes theoretical and experimental methods for characterising the performance of a 25 kHz sonochemical reactor (RV-25), which is being developed as a reference facility for studying acoustic cavitation at the National Physical Laboratory (NPL). Field measurements, acquired in different locations inside the sonoreactor, are compared with finite element models at different temperatures, showing that relatively small temperature variations can result in significant changes in the acoustic pressure distribution (and consequent cavitation activity). To improve stability, a deeper insight into the way energy is transferred from the power supply to the acoustic field is presented, leading to criteria - based on modal analysis - to dimension and verify an effective temperature control loop. The simultaneous use of measurements and modelling in this work produced guidelines for the design of multi-frequency cylindrical sonoreactors, also described.  相似文献   
10.
Shaw A  Hodnett M 《Ultrasonics》2008,48(4):234-252
This review paper examines some of the issues relating to calibration and measurement of therapeutic medical ultrasonic equipment (MUE). This is not intended to be an all-encompassing review of all aspects of characterising therapeutic ultrasound. Instead it concentrates on issues related to the acoustic output of two applications: physiotherapy and high intensity focused ultrasound surgery (HIFUS or HIFU; also referred to as high intensity therapeutic ultrasound, HITU). Physiotherapy has a well-established standards infrastructure for calibration: the requirements are small in number and well-defined. The issue for physiotherapy is not so much 'How to calibrate?' but rather, 'How to ensure that equipment IS calibrated?' The situation in the much newer area of HIFU is very different: the first steps towards writing standards are just starting and even the very basic questions of what to measure and with what type of sensor are open for debate. Readers whose main interest is in other ultrasound therapies will find ideas of relevance to their own specialty.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号