首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   72篇
  免费   1篇
化学   66篇
力学   1篇
数学   1篇
物理学   5篇
  2021年   2篇
  2020年   3篇
  2019年   2篇
  2018年   3篇
  2017年   1篇
  2016年   3篇
  2015年   2篇
  2014年   4篇
  2013年   4篇
  2012年   7篇
  2011年   5篇
  2010年   2篇
  2009年   3篇
  2008年   6篇
  2007年   4篇
  2006年   7篇
  2005年   2篇
  2004年   2篇
  2003年   2篇
  2002年   3篇
  2000年   1篇
  1998年   2篇
  1997年   1篇
  1996年   1篇
  1981年   1篇
排序方式: 共有73条查询结果,搜索用时 19 毫秒
1.
Doğutan M  Filik H  Tor I 《Talanta》2003,59(5):1053-1060
A new melamine based polymeric sequestering resin was prepared for preconcentration and separation of hexavalent chromium from water, and its sequestering action was investigated. The water-insoluble, cross-linked sequestering resin was formed by reaction with bromosuccinic acid and cross-linking of melamine. The active sequestering group on the resin is NH-(Succinic acid) or salt thereof. The resulting chelating resin was characterized by infrared spectra. The newly prepared resin quantitatively retained Cr(VI) at pH 2.0-4.0 when the flow rate was maintained between 1 and 5 ml min−1. The retained Cr(VI) was instantaneously eluted with 25 ml of 0.1 M NaOH. The chromium species were determined by a flame atomic absorption spectrometer. The limits of detection for Cr(VI) and Cr(III) were found to be 5.3 and 4.2 μg l−1, respectively. The precision and accuracy of the proposed procedure was checked by the use synthetic and reference steel samples. The established preconcentration method was successfully applied to the determination and selective separation of Cr(VI) in electroplating industry wastewater. Total concentrations determined by the spectrophotometric method (110.3±0.6 g l−1 Cr(VI) and 1.2±0.3 g l−1 Cr(III)) are compared with those found by FAAS and the obtained results (110.4±1.8 g l−1 Cr(VI) and 1.4±0.5 g l−1 Cr(III)) show good agreement.  相似文献   
2.
The method developed in this work for the separation and preconcentration of Cr(III) is based on its retention by an Amberlite XAD-2 copolymer resin functionalized with 5-palmitoyl-8-hydroxyquinoline (oxine), abbreviated XAD-POx, with the ligand covalently bound to the copolymer. Cr(III) sorption was quantitative within the pH range 4.5–7.0 and Cr(VI) was not retained. The Cr(III) held by the resin column was eluted with a hot solution of H2O2 in pH9.0 aqueous NH3–NH4Cl buffer, and Cr oxidized to CrO42– was rejected by the chelating cation-exchanger column. Any Cr(VI) originally present with Cr(III) could be reduced with an acidic solution of H2O2, and retained by the column yielding total Cr results, Cr(VI) being determined from the difference. The resin showed a maximal preconcentration factor of 60 for Cr(III), the LOD and LOQ being 9.3 and 30.1 nmol L–1, respectively. The developed preconcentration-speciation analysis was finished with a diphenylcarbazide (DPC) spectrophotometric procedure suitable for conventional laboratories. The resin showed excellent salt tolerance, enabling Cr analysis in seawater, and was stable over extended use. All the interferents of this procedure that normally occur in an electroplating effluent, a blended coal CRM, and a standard steel sample could be removed by the recommended procedure, by use of partial and total selectivity at the adsorption and desorption stages, respectively, enabling preconcentration and colorimetric determination of chromium in various complex matrices.  相似文献   
3.
A modified thiocyanate method without extraction by using rhodamine 6G as a secondary ligand was developed. Molybdenum in 1.0×10−2 M HCl, after the addition of ascorbic acid, was heated for 10 min in a 90 °C water bath for reduction. Suitable amounts of glycerine, Triton X-100, rhodamine 6G solutions and 2+1 (v/v) 9 M H2SO4+3 M KHSO4 were added in this order. This solution was allowed to cool to room temperature and the absorbance at 570 nm was measured against a reagent blank 45 min after the addition of thiocyanate solution and the second aliquot of Triton X-100 solution. The complex was stable for at least 4 h, the order of reagent addition was important, and thiocyanate should be in large excess. Beer’s law was obeyed over the range 0.9×10−6 to 1.1×10−5 M Mo with the molar absorptivity being 1.1×105 l mol−1 cm−1. The R.S.D. for the determination of 0.7 mg Mo l−1 was 1.83% (n=8). Possible interferences of various cations and anions on molybdenum determination were studied. The proposed method was applied to the determination of molybdenum in a dental alloy, Wiron 99.  相似文献   
4.
The title complex, [PdCl2(C21H26N2)(C18H15P)], shows slightly distorted square‐planar coordination around the PdII metal centre. The Pd—C bond distance between the N‐heterocyclic ligand and the metal atom is 2.028 (5) Å. The dihedral angle between the two trimethylphenyl ring planes is 36.9 (2)°.  相似文献   
5.
The stoichiometry and stability constant of metal complexes with 4-(3-methoxy-salicylideneamino)-5-hydroxynaphthalene-2,7-disulfonic acid monosodium salt (H2L) and 4-(3-methoxysalicylideneamino)-5-hydroxy-6-(2,5-dichlorophenylazo)-2,7-naphthalene disulfonic acid monosodium salt (H2L1) were studied by potentiometric titration. The stability constants of H2L and H2L1 Schiff bases have been investigated by potentiometric titration and u.v.–vis spectroscopy in aqueous media. The dissociation constants of the ligand and the stability constants of the metal complexes were calculated pH-metrically at 25 °C and 0.1 m KCl ionic strength. The dissociation constants for H2L were obtained as 3.007, 7.620 and 9.564 and for H2L1, 4.000, 6.525, 9.473 and 10.423, respectively. The complexes were found to have the formulae [M(L)2] for M = Co(II), Ni(II), Zn(II) and Cu(II). The stability of the complexes follows the sequence: Zn(II) < Co(II) < Cu(II) < Ni(II). The high stability of H2L1 towards Cu(II) and Ni(II) over the other ions is remarkable, in particular over Cu(II), and may be of technological interest. Concentration distribution diagram of various species formed in solution was evaluated for ligands and complexes. The formation of the hydrogen bonds may cause this increased stability of ligands. The pH-metric data were used to find the stoichiometry, deprotonation and stability constants via the SUPERQUAD computer program.  相似文献   
6.
7.
A series of piperidoimidazolinium salts which differ in the chain lengths (butyl, octyl, dodecyl, octadecyl) and their Pd–N‐heterocyclic carbene complexes with pyridine were synthesized and characterized using elemental analysis and spectroscopic methods. The effects of these ligands on catalyst activation and the performance of the complexes were studied in Suzuki–Miyaura reactions of arylboronic acid with aryl chlorides. The complex with the ligand having the longest chain length was found to be most active. The results demonstrated that the length of the alkyl chain of the piperidoimidazolin‐2‐ylidene controlled the dispersion and composition of the nanoparticles and it affected the catalytic activity. The impact of alkyl chain length of piperidoimidazolin‐2‐ylidene on the Suzuki–Miyaura reactions of arylboronic acid with aryl halides was systematically investigated.  相似文献   
8.
The study of individual cells with infrared (IR) microspectroscopy often requires living cells to be cultured directly onto a suitable substrate. The surface effect of the specific substrates on the cell growth—viability and associated biochemistry—as well as on the IR analysis—spectral interference and optical artifacts—is all too often ignored. Using the IR beamline, MIRIAM (Diamond Light Source, UK), we show the importance of the substrate used for IR absorption spectroscopy by analyzing two different cell lines cultured on a range of seven optical substrates in both transmission and reflection modes. First, cell viability measurements are made to determine the preferable substrates for normal cell growth. Successively, synchrotron radiation IR microspectroscopy is performed on the two cell lines to determine any genuine biochemically induced changes or optical effect in the spectra due to the different substrates. Multivariate analysis of spectral data is applied on each cell line to visualize the spectral changes. The results confirm the advantage of transmission measurements over reflection due to the absence of a strong optical standing wave artifact which amplifies the absorbance spectrum in the high wavenumber regions with respect to low wavenumbers in the mid-IR range. The transmission spectra reveal interference from a more subtle but significant optical artifact related to the reflection losses of the different substrate materials. This means that, for comparative studies of cell biochemistry by IR microspectroscopy, it is crucial that all samples are measured on the same substrate type.
Figure
Cell separation by PCA due to the refractive index of the substrate used, revealing transmission artifact.  相似文献   
9.
A Nafion-graphene (Nafion-GR) nanocomposite film modified glassy carbon electrode was fabricated by a simple drop-casting method, and used in the electrochemical detection of p-aminophenol (4-AP). Owing to the large surface area, good conductivity of GR and good affinity of Nafion, the sensor exhibited excellent electrocatalytic activity for the oxidation of 4-AP. The electrochemical behaviors of 4-AP on Nafion/GR film modified glassy carbon electrodes were investigated by cyclic voltammetry and differential pulse voltammetry. A calibration curve is constructed in the same matrix, urine, as the unknown samples to be analyzed. The Nafion-GR film modified electrode was linearly dependent on the 4-AP concentration and the linear analytical curve was obtained in the ranges of 0.5–200 μM with differential pulse voltammetry (DPV) and the detection limit was 0.051 μM. The Nafion-graphene nanocomposite modified electrode exhibited good reusability than pure graphene modified GCE. This procedure can be used for the determination of p-aminophenol in the presence of its degradation products and paracetamol. Finally, the proposed method was successfully used to determine p-aminophenol in local tap water samples in urine samples and pharmaceutical preparations.  相似文献   
10.
1 [2] [3] [4] [5] [6] [7] [8] 下一页 » 末  页»
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号