首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   10篇
  免费   0篇
化学   8篇
物理学   2篇
  2013年   2篇
  2007年   1篇
  2006年   1篇
  2005年   1篇
  2003年   1篇
  2002年   2篇
  2001年   1篇
  2000年   1篇
排序方式: 共有10条查询结果,搜索用时 31 毫秒
1
1.
A technique for coating the wells of microtiter-plates with polyaniline layers and with polyaniline/enzyme layers is presented. The resulting wells are shown to be useful for assaying enzyme substrates (as exemplified for glucose via pH) and hydrogen peroxide (via the redox properties of the film). Analyte detection is based on monitoring the absorption spectra of the polyaniline, which turn purple as a result of redox processes, or green on formation of acids by enzymatic reactions. Hydrogen peroxide (a species produced by all oxidases) and glucose (which yields protons on enzymatic oxidation) have been determined in the millimolar to micromolar concentration range. High sensitivity, film stability and good reproducibility of the measurements make the system an attractive alternative to existing biosensing schemes.  相似文献   
2.
An original concept of an enzyme multibiosensor for determination of toxic substances based on enzyme inhibition analysis has been proposed and its main performances have been analysed. For the development of this multibiosensor, two types of transducers such as potentiometric pH-sensitive field-effect transistors and conductometric thin-films interdigitated electrodes, and three enzymes, namely urease, acetylcholinesterase and butyrylcholinesterase have been used. The experimental data have been treated by multivariate correspondence analysis. A complete procedure for a simultaneous determination of some heavy metal ions and pesticides has been proposed and its advantages have been discussed.  相似文献   
3.
This paper is a review of the authors' publications concerning the development of biosensors based on enzyme field-effect transistors (ENFETs) for direct substrates or inhibitors analysis. Such biosensors were designed by using immobilised enzymes and ion-selective field-effect transistors (ISFETs). Highly specific, sensitive, simple, fast and cheap determination of different substances renders them as promising tools in medicine, biotechnology, environmental control, agriculture and the food industry.The biosensors based on ENFETs and direct enzyme analysis for determination of concentrations of different substrates (glucose, urea, penicillin, formaldehyde, creatinine, etc.) have been developed and their laboratory prototypes were fabricated. Improvement of the analytical characteristics of such biosensors may be achieved by using a differential mode of measurement, working solutions with different buffer concentrations and specific agents, negatively or positively charged additional membranes, or genetically modified enzymes. These approaches allow one to decrease the effect of the buffer capacity influence on the sensor response in an aim to increase the sensitivity of the biosensors and to extend their dynamic ranges.Biosensors for the determination of concentrations of different toxic substances (organophosphorous pesticides, heavy metal ions, hypochlorite, glycoalkaloids, etc.) were designed on the basis of reversible and/or irreversible enzyme inhibition effect(s). The conception of an enzymatic multibiosensor for the determination of different toxic substances based on the enzyme inhibition effect is also described.We will discuss the respective advantages and disadvantages of biosensors based on the ENFETs developed and also demonstrate their practical application.  相似文献   
4.
For the design of a biosensor sensitive to steroidal glycoalkaloids, pH-Sensitive Field Effect Transistors as transducers and immobilised butyrylcholinesterase as a biorecognition element have been used. The total potato glycoalcaloids can be measured by this biosensor in the concentration range 0.5-100 microM with detection limits of 0.5 microM for alpha-chaconine and of 2.0 microM for alpha-solanine and solanidine, respectively. The responses of the developed biosensors were reproducible with a relative standard deviation of about 1.5% and 5% for intra- and inter-sensor responses (both cases, n=10, for an alkaloid concentration of 5 microM), respectively. Moreover, due to the reversibility of the enzyme inhibition, the same sensor chip with immobilised butyrylcholinesterase can be used several times (for at least 100 measurements) after a simple washing by a buffer solution and can be stored at 4 degrees C for at least 3 months without any significant loss of the enzymatic activity.  相似文献   
5.
The key theoretical principles of the work on ion-selective field-effect transistor connected with their application in bioanalytical practice, some specifics of modern microtechnologies for their creation, and measurement schemes with set-ups are discussed. The achievements in the creation of enzyme biosensors based on ion-selective field-effect transistors and prospects for their application are described in detail.  相似文献   
6.
New R 2Ti3Ge4 (R=Dy, Ho and Er) intermetallic compounds have been synthesized and characterized by X-ray diffraction and low temperature ac magnetic susceptibility, electrical resistivity and thermoelectric power measurements were carried out. The compounds crystallize in the parent, Sm5Ge4-type orthorhombic structure (space group Pnma) and lanthanide contraction is observed as one moves along the rare-earth series. The changeover from paramagnetic to antiferromagnetic phase happens at low temperatures and the ordering temperature scales with the de Gennes factor. The electrical resistivity is metallic with a negative curvature above 100 K. Thermopower displays a weak maximum at temperatures less than 50 K signifying the possible phonon and magnon drag effects.  相似文献   
7.
Porous molecularly imprinted polymer membranes and polymeric particles   总被引:1,自引:0,他引:1  
Porous free-standing molecularly imprinted polymer membranes were synthesised by the method of in situ polymerisation using the principle of synthesis of interpenetrating polymer networks and tested in solid-phase extraction of triazine herbicides from aqueous solutions. Atrazine-specific MIP membranes were obtained by the UV-initiated co-polymerisation of methacrylic acid, tri(ethylene glycol) dimethacrylate, and oligourethane acrylate in the presence of a template (atrazine). Addition of oligourethane acrylate provided formation of the highly cross-linked MIP in a form of a free-standing 60 μm thick flexible membrane. High water fluxes through the MIP membranes were achieved due to addition of linear polymers (polyethylene glycol Mw 20,000 and polyurethane Mw 40,000) to the initial mixture of monomers before the polymerization. As a result, typical semi-interpenetrating polymer networks (semi-IPNs) have been formed, where the cross-linked polymer was represented by the atrazine-specific molecularly imprinted polymer, while the linear one was represented by polyethylene glycol/polyurethane. Extraction of the linear polymers from the fully formed semi-IPNs resulted in formation of large pores in the membrane structure. At the same time, extraction of the template molecules lead to formation of the sites in the polymeric network, which in shape and arrangement of functional groups are complementary to atrazine. Reference polymeric membranes were prepared from the same mixture of monomers but in the absence of the template. Recognition properties of the MIP membranes were estimated in solid-phase extraction by their ability to selective re-adsorbtion of atrazine from 10−8 to 10−4 M aqueous solutions. The imprinting effect was demonstrated for both types of the MIP membranes and the influence of the type of the linear compound on their recognition properties was estimated. The recognition properties of the MIP membranes were compared to those of the MIP particles of the same composition. Morphology of the MIP membranes was investigated using the SEM microscopy. High fluxes of the developed membranes together with high affinity and adsorption capability make them an attractive alternative to MIP particles in separation processes.  相似文献   
8.
DS Agosta  AV Skripov 《哲学杂志》2013,93(2):299-306
Resonant ultrasound spectroscopy was used to measure the elastic constants of bcc Ta0.33V0.67 over the temperature range 3.5–300?K; the results were compared to earlier measurements on C15 TaV2. The temperature dependence of the polycrystalline shear modulus is completely different in the two phases; that of the bcc phase decreases with temperature whereas that of the C15 phases increases in an anomalous fashion. This difference is consistent with a model involving doubly-degenerate levels at the X point of the Brillouin zone in the C15 phase with the Fermi level lying near the doubly degenerate level. This model accounted for the unusual behaviour of the C15 phase. Debye temperatures were determined from the ultrasonic measurements: 295?K for the C15 phase and 315?K for the bcc phase.  相似文献   
9.
An easy-to-use colorimetric test-system for the efficient detection of creatinine in aqueous samples was developed. The test-system is based on composite molecularly imprinted polymer (MIP) membranes with artificial receptor sites capable of creatinine recognition. A thin MIP layer was created on the surface of microfiltration polyvinylidene fluoride (PVDF) membranes using method of photo-initiated grafting polymerization. The MIP layer was obtained by co-polymerization of a functional monomer (e.g. 2-acrylamido-2-methyl-1-propanesulfonic acid, itaconic acid or methacrylic acid) with N, N′-methylenebisacrylamide as a cross-linker. The choice of the functional monomer was based on the results of computational modeling. The creatinine-selective composite MIP membranes were used for measuring creatinine in aqueous samples. Creatinine molecules were selectively adsorbed by the MIP membranes and quantified using color reaction with picrates. The intensity of MIP membranes staining was proportional to creatinine concentration in an analyzed sample. The colorimetric test-system based on the composite MIP membranes was characterized with 0.25 mM detection limit and 0.25–2.5 mM linear dynamic range. Storage stability of the MIP membranes was estimated as at least 1 year at room temperature. As compared to the traditional methods of creatinine detection the developed test-system is characterized by simplicity of operation, small size and low cost.  相似文献   
10.
The applicability of an enzyme biosensor based on pH-ISFETs for direct determination of total glycoalkaloids content in real potato samples, without any pre-treatment, is shown. The results of determination of the total glycoalkaloids concentrations in potato samples from different experimental varieties obtained by the biosensor are well correlated with the analogous data obtained by the HPLC method with standard complex sample pre-treatment procedure. The detection of total glycoalkaloids content by biosensors is reproducible, the relative standard deviation was around 3%. The dependence of total glycoalkaloids content on various parts of the potato tuber and their size, different growing area has been shown using the biosensor developed.The method based on biosensors is cheap, easy to operate and requires a shorter analysis time than the one needed using traditional methods for glycoalkaloids determination. The biosensor can operate directly on potato juice, or even directly on a suspension of potato or plant material. It can provide a way to save time and costs, with a possibility of taking rapid assessment of total glycoalkaloids content in a wide variety of potato cultivars. Furthermore the operational and storage stability of this biosensor are quite good with a drift lower than 1% per day and response being stable for more than 3 months.  相似文献   
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号