首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   10篇
  免费   1篇
化学   7篇
力学   1篇
物理学   3篇
  2022年   1篇
  2006年   2篇
  2003年   1篇
  2001年   1篇
  2000年   2篇
  1999年   2篇
  1993年   1篇
  1981年   1篇
排序方式: 共有11条查询结果,搜索用时 15 毫秒
1.
HIV protease inhibitors are important antiretroviral drugs which have substantially reduced the morbidity and mortality associated with HIV-1 infection. Recent data have shown relationships between plasma concentrations of the protease inhibitors and clinical response, which makes therapeutic drug monitoring valuable. We have developed and validated an assay, using liquid chromatography coupled with electrospray tandem mass spectrometry (LC/MS/MS), for the routine quantification of the six licensed protease inhibitors (amprenavir, indinavir, lopinavir, nelfinavir, ritonavir and saquinavir) and the pharmacologically active nelfinavir metabolite M8 in plasma. The sample pretreatment consisted of protein precipitation with a mixture of methanol and acetronitrile using only 100 microl of plasma. Chromatographic separation was performed on an Inertsil ODS3 column (50 x 2.0 mm i.d., particle size 5 microm), with a quick stepwise gradient using an acetate buffer (pH 5) and methanol, at a flow rate of 0.5 ml min(-1). The analytical run time was 5.5 min. The use of a 96-well plate autosampler allowed batch sizes up to 150 patient samples. The triple-quadrupole mass spectrometer was operated in the positive ion mode and multiple reaction monitoring was used for drug quantification. The method was validated over the concentration ranges 0.01-10 microg ml(-1) for indinavir and saquinavir, 0.1-10 microg ml(-1) for amprenavir, 0.05-10 microg ml(-1) for nelfinavir and ritonavir, 0.1-20 microg ml(-1) for lopinavir and 0.01-5 microg ml(-1) for M8. Saquinavir-d(5) and indinavir-d(6) were used as internal standards. The coefficients of variation were always <10% for both intra-day and inter-day precisions for each compound. Mean accuracies were also between the designated limits (+/-15%). The validated concentration ranges proved to be adequate in daily practice. This robust and fast LC/MS/MS assay is now successfully applied for routine therapeutic drug monitoring and pharmacokinetic studies in our hospital.  相似文献   
2.
Large enhancements have been observed in the sub-barrier fusion cross sections for Ti+Ni systems in our previous studies. Coupled channel calculations incorporating couplings to 2+ and 3 states failed to explain these enhancements completely. A possibilty of transfer channels contributing to the residual enhancements had been suggested. In order to investigate the role of relevant transfer channels, measurements of one- and two-nucleon transfer were carried out for 46,48Ti+61Ni systems. The present paper gives the results of these studies.  相似文献   
3.
Understanding the relation between spatial heterogeneity and structural rejuvenation is one of the hottest topics in the field of metallic glasses (MGs). In this work, molecular dynamics (MD) simulation is implemented to discover the effects of initial spatial heterogeneity on the level of rejuvenation in the Ni$_{80}$P$_{20 }$MGs. For this purpose, the samples are prepared with cooling rates of $10^{10}$ K/s-$10^{12}$ K/s to make glassy alloys with different atomic configurations. Firstly, it is found that the increase in the cooling rate leads the Gaussian-type shear modulus distribution to widen, indicating the aggregations in both elastically soft and hard regions. After the primary evaluations, the elastostatic loading is also used to transform structural rejuvenation into the atomic configurations. The results indicate that the sample with intermediate structural heterogeneity prepared with 10$^{11}$ K/s exhibits the maximum structural rejuvenation which is due to the fact that the atomic configuration in an intermediate structure contains more potential sites for generating the maximum atomic rearrangement and loosely packed regions under an external excitation. The features of atomic rearrangement and structural changes under the rejuvenation process are discussed in detail.  相似文献   
4.
A host-guest optical sensor for the determination of aliphatic amines as exemplified by octylamine is proposed. It is based on the reversible fluorescence enhancement of heptakis(2,6-di-O-isobutyl)-β-cyclodextrin(DOB-β-CD) hosting tetraphenylporphyrin (TPP) immobilized in poly(vinyl chloride) (PVC) membrane by aliphatic amine extracted from aqueous phase into membrane phase. The optimum membrane contained 1.15 wt % TPP, 6.15 wt % DOB-β-CD as sensing reagent and other membrane materials. The fluorescence enhancement of the membrane resulted from the formation of a stable three-component complex among DOB-β-CD, TPP, and aliphatic amines. With the optimum conditions described, the fluorescence response of the sensor to octylamine shows a good correlation with the theoretically derived equation in the range 1.0 × 10–6 to 8.0 × 10–4 mol/L. The response characteristics including reversibility, response time, reproducibility and lifetime and selectivity of this optical device are also discussed in detail. This sensor has also been applied for the determination of octylamine in water samples containing interferents with satisfactory recovery.  相似文献   
5.
This paper describes the investigation of the potential of a quadrupole orthogonal acceleration time-of-flight mass spectrometer (Q-TOF) equipped with an atmospheric pressure ionisation interface for quantitative measurements of small molecules separated by reversed phase liquid chromatography. To this end, the detection limits and linear dynamic range in particular were studied in an LC/MS/MS experiment using 3,4-methylenedioxymethamphetamine standards and 3,4-methylenedioxyethylamphetamine for internal standardisation. In a second phase, the experiment was repeated with real biological extracts (whole blood, serum, and vitreous humour). A calibration for 3,4-methylenedioxymethamphetamine and its metabolite 3,4-methylenedioxyamphetamine was prepared in each of these matrices again using 3,4-methylenedioxyethylamphetamine as internal standard. The resulting quantitative data were compared with those obtained by liquid chromatography with fluorescence detection for the same extracts. The Q-TOF results revealed excellent sensitivity and a linear dynamic range of nearly four decades (2-10 000 pg on-column, r(2) = 0.9998, 1/x weighting). Furthermore, all the calibration curves prepared in biological material were superimposable, LC/MS/MS and LC-fluorescence, and the quantitative results for actual samples compared very favourably. It was concluded that the Q-TOF achieves a linear dynamic range for quantitative LC/MS/MS work exceeding that of fluorescence detection and at much better absolute sensitivity. Copyright 1999 John Wiley & Sons, Ltd.  相似文献   
6.
The effects on the radiation response of Harwell polymethylmethacrylate (PMMA) dosimeters of dose-rate, radiation type, temperature during irradiation and post-irradiation storage, and post-irradiation stability, are of importance to the operators of commercial irradiation facilities.

This paper describes recent studies of the effects of some of these parameters on the radiation response of Harwell Red 4034, Amber 3042, and Gammachrome YR Perspex dosimeters, and provides data on batch to batch variation and shelf-life.  相似文献   

7.
Tipranavir is the most recently introduced protease inhibitor for the suppression of the human immunodeficiency virus (HIV). A selective reversed-phase liquid chromatographic assay, previously developed for atazanavir, has been extended and validated for tipranavir in plasma. Compounds were isolated from a 500 microL plasma sample using liquid-liquid extraction with dichloromethane. After evaporation and reconstitution of the extract the sample was analysed using reversed-phase liquid chromatography and ultra violet detection at 280 nm. In the evaluated concentration range (0.2-50 microg/mL tipranavir), intra-day precisions were 相似文献   
8.
9.
n.O.e. difference spectra reveal that the preferred solution conformation of methyl enol ethers has the methyl group syn-periplanar to the double bond; n.O.e kinetics in a methoxy—heptatriene demonstrate the presence of both possible periplanar conformations, the energy difference being ca 1 kcal/mole.  相似文献   
10.
Atazanavir is the most recently introduced protease inhibitor for the suppression of the anti-human immunodeficiency virus. A sensitive and selective reversed-phase liquid chromatographic assay for this drug in human plasma has been developed and validated. Atazanavir was isolated from a 500 microL plasma sample using liquid-liquid extraction with dichloromethane. After evaporation and reconstitution of the extract the sample was analysed using liquid chromatography and ultraviolet detection at 280 nm. In the evaluated concentration range (44-4395 ng/mL atazanavir), intra-day precisions were < or =7% and inter-day precisions were < or =14%. Accuracies between 96 and 106% were found. The lower limit of quantification was 44 ng/mL with an intra-day precision of 7%, an inter-day precision of 14% and an accuracy of 87%. There was no interference from 32 tested potentially co-administrated drugs and metabolites. The usefulness of the assay was demonstrated for samples obtained from an HIV-infected patient treated with atazanavir.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号