首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   78篇
  免费   1篇
化学   50篇
力学   4篇
数学   3篇
物理学   22篇
  2019年   1篇
  2018年   1篇
  2016年   1篇
  2014年   2篇
  2013年   3篇
  2011年   4篇
  2010年   6篇
  2009年   4篇
  2008年   4篇
  2007年   6篇
  2006年   7篇
  2005年   7篇
  2004年   4篇
  2003年   4篇
  2002年   1篇
  2001年   4篇
  2000年   1篇
  1999年   4篇
  1997年   2篇
  1996年   6篇
  1995年   1篇
  1994年   1篇
  1993年   2篇
  1986年   1篇
  1980年   1篇
  1974年   1篇
排序方式: 共有79条查询结果,搜索用时 31 毫秒
1.
The MPEG-1 Layer 3 compression schema of audio signal, commonly known as mp3, has caused a great impact in recent years as it has reached high compression rates while conserving a high sound quality. Music and speech samples compressed at high bitrates are perceptually indistinguishable from the original samples, but very little was known about how compression acoustically affects the voice signal. A previous work with normal voices showed a high fidelity at high-bitrate compressions both in voice parameters and the amplitude-frequency spectrum. In the present work, dysphonic voices were tested through two studies. In the first study, spectrograms, long-term average spectra (LTAS), and fast Fourier transform (FFT) spectra of compressed and original samples of running speech were compared. In the second study, intensities, formant frequencies, formant bandwidths, and a multidimensional set of voice parameters were tested in a set of sustained phonations. Results showed that compression at high bitrates (96 and 128 kbps) preserved the relevant acoustic properties of the pathological voices. With compressions at lower bitrates, fidelity decreases, introducing some important alterations. Results from both works, Gonzalez and Cervera and this paper, open up the possibility of using MPEG-compression at high bitrates to store or transmit high-quality speech recordings, without altering their acoustic properties.  相似文献   
2.
3.
The determination of cadmium in different sample types has been carried out by electrothermal atomization atomic absorption spectrometry with D(2)-background correction using a unpyrocoated graphite tube, after pressurized microwave-assisted digestion. Five chemical modifiers [(NH(4))(2)HPO(4), Pd(NO)(3))(2), Ni(NO(3))(2), thiourea and Triton X-100] have been assayed and nickel nitrate has been found to be most effective for an accurate determination of cadmium in mussel tissue, pig kidney and sewage sludge. The characteristic mass of the method is of the order of 1 pg and the limit of detection is lower than 0.1 ng/ml.  相似文献   
4.
The aim of this study is to show the advantages of the emerging multicommutation methodology based on the use of solenoid valves for Te determination in milk by hydride generation atomic fluorescence spectrometry (HG-AFS). The delivery of a series of alternating sequential insertions of small volumes of samples and reagents gives rise to new hydrodynamic processes and exciting analytical potentials by controlling the time of flow through the on/off-switched solenoid valves. This drastically reduces the reagent consumption by a factor of 4 and the generation of effluents (590 mL h–1 instead of 750 mL h–1 generated by the continuous-mode measurement) and also provides an improvement in the laboratory productivity by an increase of the sample throughput (85 h–1 compared to 20 h–1 found in the continuous mode). So, multicommutation is an environmentally and economically sustainable alternative to the methodology based on continuous measurements. The multicommutation-based method developed was applied to tellurium determination in commercially available milk samples; a calibration range of 0.0–0.5 ng mL–1 and a detection limit of 0.20 ng L–1 with average relative standard deviation of 2.1% were found. Comparable results were obtained for a series of samples using both continuous and multicommutation HG-AFS modes.  相似文献   
5.
Critical review of the atomic spectrometric analysis of arsenic in foods   总被引:1,自引:0,他引:1  
The literature on the determination of arsenic in foods by atomic spectroscopy involving hydride generation, platform furnace Zeeman and inductively coupled plasma has been critically reviewed. Hydride generation has been largely displaced as a powerful tool by platform furnace Zeeman, using the STPF (stabilized temperature platform furnace) concept for the control of interferences. Inductively coupled plasma with conventional pneumatic nebulization has been little used. An alternative is to employ hydride generation-ICP with extraction of the arsenic in an organic phase. This technique permits proper control of interferences together with an increase in sensitivity. Depending on the contents present in the foodstuff and the technique available, the sample can be solubilized by either wet or dry digestion.  相似文献   
6.
A new method has been developed for measuring local adsorption rates of metal ions at interfaces based on scanning electrochemical microscopy (SECM). The technique is illustrated with the example of Ag+ binding at Langmuir phospholipid monolayers formed at the water/air interface. Specifically, an inverted 25 microm diameter silver disc ultramicroelectrode (UME) was positioned in the subphase of a Langmuir trough, close to a dipalmitoyl phosphatidic acid (DPPA) monolayer, and used to generate Ag+ via Ag electro-oxidation. The method involved measuring the transient current-time response at the UME when the electrode was switched to a potential to electrogenerate Ag+. Since the Ag+/Ag couple is reversible, the response is highly sensitive to local mass transfer of Ag+ away from the electrode, which, in turn, is governed by the interaction of Ag+ with the monolayer. The methodology has been used to determine the influence of surface pressure on the adsorption of Ag+ ions at a phospholipid (dipalmitoyl phosphatidic acid) Langmuir monolayer. It is shown that the capacity for metal ion adsorption at the monolayer increased as the density of surface adsorption sites increased (by increasing the surface pressure). A model for mass transport and adsorption in this geometry has been developed to explain and characterise the adsorption process.  相似文献   
7.
A microwave assisted digestion procedure has been developed for dissolution of fly ash samples prior to the inductively coupled plasma-mass spectrometric determination of their elemental composition. The developed methodology was validated by carrying out the analysis of two high-silicate containing reference materials (CRM 134R sewage amended soil and NIES JR 1 rock) and by means of the comparison between results found by microwave-assisted digestion and ICP-MS of fly ash samples with those found by neutron activation analysis (NAA) for Sb, Cs, Cr, Co, Fe, U and Zn determination. The method developed can be recommended for routine multielement analysis of fly ash.  相似文献   
8.
A simple and fast analytical procedure has been developed for the determination of As, Sb, Se, Te and Bi in milk samples by hydride generation atomic fluorescence spectrometry (HG-AFS). Samples were treated with aqua regia for 10 min in an ultrasound water bath and pre-reduced with KBr for total Se and Te determination or with KI and ascorbic acid for total As and Sb, the determination of Bi being possible in all with or without pre-reduction. Slurries of samples, in the presence of antifoam A, were treated with NaBH4 in HCl medium to obtain the corresponding hydrides, and AFS measurements were processed in front of external calibrations prepared and measured in the same way as samples. Results obtained by the developed procedure compare well with those found after microwave-assisted complete digestion of samples. The proposed method is simple and fast, and only 1 ml of milk is needed. The values obtained for detection limit are 2.5, 1.6, 3, 6 and 7 ng l−1 for As, Sb, Se, Te and Bi respectively in the diluted samples, with average relative standard deviation values of 3.8, 3.1, 1.9, 6.4 and 1.2% for three independent analysis of a series of commercially available samples of different origin. Data found in Spanish market samples varied from 3.2±0.3 to 11.3±0.2 ng g−1 As, from 3.1±0.2 to 11.6±0.4 ng g−1 Sb, from 10.7±0.5 to 25.5±0.4 ng g−1 Se, from 0.9±0.2 to 9.4±0.6 ng g−1 Te and from 11.5±0.1 to 27.7±0.4 ng g−1 Bi.  相似文献   
9.
We present results for nu(mu) oscillation in the KEK to Kamioka (K2K) long-baseline neutrino oscillation experiment. K2K uses an accelerator-produced nu(mu) beam with a mean energy of 1.3 GeV directed at the Super-Kamiokande detector. We observed the energy-dependent disappearance of nu(mu), which we presume have oscillated to nu(tau). The probability that we would observe these results if there is no neutrino oscillation is 0.0050% (4.0 sigma).  相似文献   
10.
A systematic study of noise barriers based on sonic crystals made of cylinders that use recycled materials like absorbing component is reported here. The barriers consist of only three rows of perforated metal shells filled with rubber crumb. Measurements of reflectance and transmittance by these barriers are reported. Their attenuation properties result from a combination of sound absorption by the rubber crumb and reflection by the periodic distribution of scatterers. It is concluded that the porous cylinders can be used as building blocks whose physical parameters can be optimized in order to design efficient barriers adapted to different noisy environments.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号