1.
An on-line time based injection system used in conjunction with cold vapor generation atomic absorption spectrometry and microwave-aided oxidation with potassium persulfate has been developed for the determination of the different mercury species in fish-eggs oil samples. A three-phase surfactant-oil-water emulsion produced an advantageous flow when a peristaltic pump was used to introduce the highly viscous sample into the system. The optimum proportion of the oil-water mixture ratio was 2:3 v/v with a Tween 20 surfactant concentration in the emulsion of 0.008% v/v. Inorganic mercury was determined after reduction with sodium borohydride while total mercury was determined after an oxidation step with persulfate prior to the reduction step to elemental mercury with the same reducing agent. The difference between total and inorganic mercury determined the organomercury content in samples. A linear calibration graph was obtained in the range 0.1-20 micrograms l-1 of Hg2+ by injecting 0.7 ml of samples. The detection limits based on 3 sigma of the blank signals were 0.11 and 0.12 microgram l-1 for total and inorganic mercury, respectively. The relative standard deviation of ten independent measurements were 2.8 and 2.2% for 10 micrograms l-1 and 8.8 and 9.0% for 0.1 microgram l-1 amounts of total and inorganic mercury, respectively. The recoveries of 0.3, 0.6 and 8 micrograms l-1 of inorganic and organic mercury added to fish-eggs oil samples ranged from 93.0 to 94.8% and from 100 to 106%, respectively. Good agreement with those values obtained for total mercury content in real samples by electrothermal atomic absorption spectrometry was also obtained, differences between mean values were < 7%. With the proposed procedure, 22 proteropterous catfish-eggs oil samples from the northwestern coast of Venezuela were measured; while the organic mercury lay in the range 2.0 and 3.3 micrograms l-1, inorganic mercury was not detected.  相似文献   
2.
This report describes the determination of paraquat (PQ) in human blood plasma samples by a direct-injection reversed-phase ion-pair chromatographic method. Blood plasma filtrate was injected directly into the LiChrospher® RP-18 alkyl-diol silica (ADS) precolumn integrated in a column switching system using a mixture of 3% 2-propanol and 10 mM sodium octane sulfonate (SOS) in a 0.05 M phosphate buffer (pH 2.8). After washing with this phase, the ADS precolumn was back-flushed with the analytical mobile phase consisting of 40% of methanol and 10 mM SOS in a 0.05 M phosphate buffer (pH 2.8) at a flow rate of 1.0 ml min−1, in order to carry the analyte to a conventional reversed-phase analytical column, where the separation of PQ was achieved and finally detected by UV at 258 nm. The recoveries of PQ from human blood plasma samples ranged between 95.0 and 99.5% at nine different concentrations (from 0.05 to 3.00 μg of PQ ml−1) with coefficients of variation <2.5% (n=3). The precision expressed as relative standard deviation was below 3.5% for between-day and below 4.3% for within-day measurements (n=5). The detection limit (signal-to-noise ratio, S/N>3) was 0.005 μg ml−1 with an injection volume of 200 μl. The proposed method is promising for the identification and quantification of PQ at low concentration levels and is suitable for its analysis in human blood plasma samples from intentional or accidental poisonings cases with a sample throughput of 5 samples per hour.  相似文献   
3.
Lead is extracted from urine with ammonium pyrrolidien dithiocrbamate into methyl isobutyl ketone, and 20 μl of the extract is injected into a water carrier stream in a flow-injection/atomic absorption system. The procedure is simple, quick, accurate and reproducible. Recoveries are 96–105%. The mean urine lead contents of 20 unexposed and 20 printing-press lead exposed workers was found to be 39.0 ± 8.3 and 71.7 ± 26.3 μg Pb l?1, respectively.  相似文献   
4.
The addition of the lithium anions derived from (R)- and (S)-methyl and -ethyl p-tolyl sulfoxides to (S)-N-benzylidene-p-toluenesulfinamide provides an easy access route to enantiomerically pure beta-(N-sulfinyl)amino sulfoxides. Stereoselectivity can be achieved when the configurations at the sulfur atoms of the two reagents are opposite (matched pair), thus resulting in only one diastereoisomer, even for the case in which two new chiral centers are created. The N-sulfinyl group primarily controls the configuration of the carbon bonded to the nitrogen, whereas the configuration of the alpha-sulfinyl carbanion seems to be responsible for the level of asymmetric induction, as well as for the configuration of the new stereogenic C-SO carbon in the reactions with ethyl p-tolyl sulfoxides. An efficient method for transforming the obtained beta-(N-sulfinyl)amino sulfoxides into optically pure beta-amino alcohols, based on the stereoselective non-oxidative Pummerer reaction, is also reported.  相似文献   
5.
6.
Burguera M  Burguera JL  Carrero P  Rondón C 《Talanta》2002,58(6):1157-1166
In this work total (Si-tot) and ‘soluble’ or reactive (Si-sol) concentrations of silicon in natural and tap waters were sequentially determined by electrothermal atomic absorption spectrometry (ETAAS). First, samples were on-line diluted based on the merging-zone principle in order to allow the determination of Si-tot within the 300–1000 μgSi l−1 range. After the dilution process, a sub-sample was collected in the capillary of a sampling arm assembly (SAA). Thereafter, samples were subject to a precipitation/dissolution process in order to allow the determination of Si-sol within the 280–850 μgSi l−1. Si-sol was precipitated with ammonium chloride and collected on the walls of a knotted coil. The precipitate was dissolved with ammonium molybdate in an acidic medium (HNO3) and a sub-sample was then collected in the SAA. In both cases, 10 μl volumes of the sub-sample were injected into the atomizer with the previous introduction of 20 ng of Eu as chemical modifier (10 μl) by the spectrometer autosampler. The recovery values obtained with natural waters spiked samples were over 46% and the agreement between observed and certified samples values was good. The proportion of Si-sol in comparison with the Si-tot was high (85–95%) in most natural waters. The precision of the method was 2.4–3.5 and 4.5–6.2% (n=10) for the determination of Si-tot and Si-sol, respectively.  相似文献   
7.
In this paper, the on-line coupling of solid-phase extraction, based on a restricted-access support with high-performance reverse phase chromatography for the analysis of carbamazepine (CBZ) and carbamazepine-10,11-epoxide (CBZ-E) in human plasma samples is described. A precolumn packed with 25 mum C(18) alkyl-diol support is used for direct plasma injection. Using column-switching techniques, the analytes were enriched on the precolumn by a 5 mM phosphate buffer (pH 7) with 2% of methanol solution at a flow-rate of 0.8 ml min(-1), while proteins and endogenous hydrophilic substances in plasma were washed off to waste. The enriched analytes were then back-flushed onto the analytical C(18) column, separated by a mixture of 10 mM phosphate buffer (pH 7) acetonitrile (70:30 v/v) solution at a flow-rate of 1.0 ml min(-1) and detected by the ultraviolet absorbance set at 212 and 285 nm and without transfer loss. Linear calibration graphs were obtained for sample injection volumes of 50 (0.2-4.0 of mug of CBZ ml(-1) and 0.1-5.0 mug of CBZ-E ml(-1), respectively), and 20 mul (5.0-20.0 mug of CBZ ml(-1)); in either case the r-value was >0.9963. Recoveries from spiked plasma samples were quantitative for both analytes and the coefficients of variation were below 3.83%. The lowest samples concentrations that can be quantified with acceptable accuracy and precision was 0.2 mug CBZ ml(-1) and 0.1 mug CBZ-E ml(-1) when a sample volume of 50 mul was injected. Concentrations of 0.08 and 0.05 mug ml(-1) of CBZ and CBZ-E were considered the limit of detection for a signal-to-noise ratio of 3. Furthermore, the developed column-switching method was successfully applied to the determination of CBZ and CBZ-E in plasma samples of patients submitted to CBZ therapy.  相似文献   
8.
Burguera JL  Townshend A 《Talanta》1981,28(10):731-735
Manganese(II) ( 1.5 ng/ml) is determined by measuring either of the two emission peaks given by alkaline oxidation of luminol. Several other metal ions, which enhance both emission peaks, are masked by cyanide ions.  相似文献   
9.
In this work, a flow analysis system with hydride generation and Fourier transform infrared (FTIR) spectrometric detection has been developed for the determination of antimony in pharmaceuticals. The method is based on the on-line mineralization/oxidation of the organic antimonials present in the sample and pre-reduction of Sb(V) to Sb(III) with K2S2O8 and KI, respectively; prior to the stibine generation. The gaseous SbH3 is separated from the solution in a gas phase separator, and transported by means of a nitrogen carrier into a short pathway (10 cm) IR gas cell, where the corresponding FTIR spectrum is acquired by accumulating 3 scans in a continuous mode. The 1893 cm−1 band was used for the quantification of the antimony. The procedure is carried out in a closed system, which reduces sample handling and makes possible the complete automation of the antimony determination. The figures of merit of the proposed method (linear range: 0-600 mg l−1, limit of detection (3σ)=0.9 mg l−1, limit of quantification (10σ)=3 mg Sb l−1, precision (R.S.D.) less than 1% and sample frequency=28 h−1), are appropriate for the designed application. Furthermore, precise and accurate results were found for the analysis of different antimonial pharmaceutical samples, indicating that the methodology developed represents a valid alternative for the determination of antimony in pharmaceuticals, which could be suitable for the routine control analysis.  相似文献   
10.
In this work, the coupling between flow analysis (FA)–vapor phase generation (VPG) and Fourier transform infrared spectrometry (FTIR) has been proposed as a novel and alternative strategy for the determination of nitrite. The analyte was transformed into the gaseous nitric oxide (NO) by on-line reaction with potassium iodide (KI) or ascorbic acid in acidic medium. The gaseous NO generated was transported by means of a N2 gas carrier stream inside the IR gas cell and the corresponding FTIR spectrum was acquired in a continuous mode. The absorbance at 1876 cm−1, corrected by a baseline established between 1879 and 1872 cm−1 at a nominal resolution of 2 cm−1, was selected as a measurement criterion. The effect of different spectroscopic and flow analysis experimental parameters, such as nominal resolution, number of scans, reducing agent and its concentration, acidic medium, reagents and sample flow rates, and the carrier gas flow rate on the analytical signal, and then in the figures of merit were initially evaluated by using a standard short path length (10 cm) IR gas cell. The optimization of the system was carried out by the univariate method. The main aims of this study were: (i) to investigate the on-line generation of gaseous nitric oxide in a continuous flow system, and (ii) the use of Fourier transform infrared spectrometry as an alternative and selective detector for the determination of nitrite. The proposed method was initially tested and applied for the determination of nitrite in samples with very high concentration of nitrite, such as frankfurters.  相似文献   